AP® Chemistry · Unit 3 · Topic 3.13

Beer-Lambert Law: Revision Notes (Chemistry 3.13)

One-page recap of A = εbc, molar absorptivity, choosing λmax, calibration curves and the lab errors that push a calculated concentration too high or too low.

Short on time? This page is the recap. For explanations, diagrams and worked examples, use the full study guide.

Recap

  • A solution absorbs light when its particles absorb photons of a matching energy. Absorbance, A, measures how much.
  • The Beer-Lambert law: A = εbc.
  • ε (molar absorptivity) says how strongly one species absorbs one wavelength. It depends on the species and the wavelength, not on concentration.
  • b (path length) and c (concentration) together set how many absorbing particles the beam meets, so A is proportional to each.
  • With the same cuvette and wavelength, A is proportional to c alone. A graph of A against c for standards is a straight line through the origin with gradient εb: a calibration curve.
  • Set the spectrophotometer to λmax, the wavelength of maximum absorbance: biggest ε, most sensitive, least affected by small wavelength drift.
  • Zero the instrument with a blank (cuvette plus solvent) first.

Key relationships

Relationship Symbols and units Use it to
A = εbc A no unit; ε in M⁻¹ cm⁻¹; b in cm; c in M find any one quantity from the other three
c = A ÷ (εb) as above find the concentration of an unknown
gradient of A against c = εb gradient in M⁻¹ get ε from a calibration curve (ε = gradient ÷ b)
c(original) = c(measured) × dilution factor dilution factor = final volume ÷ sample volume undo a dilution made before measuring

Assumptions behind the numbers

  • Only one species absorbs at the chosen wavelength (or the blank removes everything else).
  • Path length and wavelength are the same for the standards and the unknown.
  • The unknown’s absorbance lies within the range of the standards, where the line is straight.
  • The solution is clear: nothing in it scatters light.

Mistakes to avoid

  1. Giving A a unit. It has none.
  2. Thinking ε changes with concentration. It does not.
  3. Picking the wavelength with the least absorbance. Use λmax.
  4. Forgetting the dilution factor after reading the calibration line.
  5. Wrong error direction. Smudges, bubbles, cloudiness and a longer cuvette raise A (c too high). Water droplets that dilute the sample lower A (c too low).
  6. Vague error answers. Say whether A goes up or down, then link to c.

Quick self-check

  1. A 3.00 × 10⁻⁵ M solution in a 1.00 cm cuvette has A = 0.450. What is ε? (1.50 × 10⁴ M⁻¹ cm⁻¹)
  2. A solution has A = 0.20 in a 1.00 cm cuvette. What is A in a 2.00 cm cuvette? (0.40)
  3. You halve the concentration and double the path length. What happens to A? (No change: the beam meets the same number of particles.)
  4. Air bubbles are stuck in the cuvette holding the unknown. Is the calculated c too high or too low? (Too high: bubbles scatter light, so A reads too high.)

Next: practice questions.

AP® and Advanced Placement® are trademarks registered by the College Board, which is not affiliated with, and does not endorse, this website. Marlbridge is an independent tuition provider. It is not an authorized AP course provider, an AP school or an exam centre, and these resources are not official College Board materials. Reading them or doing simulations does not meet the laboratory requirement of an AP science course.