Answer
Flashcards · 9630 · A Level Topic 13
Energy sources (A Level) flashcards
21 cards on A Level Topic 13, subtopics 3.13.1 to 3.13.4. Pick a subtopic or study them all.
Study mode needs JavaScript. Every card is listed below, so you can still cover the answers and test yourself.
Choose your cards
Session complete
Worth another look:
All 21 cards
For a quick read-through or printing. Cover the right-hand side to test yourself.
3.13.1 Rotational motion
- Moment of inertia: definition and what it depends on
- A measure of how hard it is to change an object's rotation about an axis: I = Σmr² (kg m²). It depends on the mass, how the mass is distributed about the axis, and the axis.
- Torque and rotational Newton's second law
- Torque T = Fr, with r the perpendicular distance from the axis to the line of the force. Resultant torque T = Iα, where α is the angular acceleration.
- Rotational kinetic energy, work and power
- Ek(rot) = ½Iω². Work done by a torque W = Tθ. Power P = Tω.
- Conservation of angular momentum
- Angular momentum Iω of a system stays constant if no external resultant torque acts on it.
- A spinning diver tucks in, reducing I from 3.6 to 1.2 kg m². What happens to ω (1.5 rad s⁻¹) and Ek?
- Iω is conserved: ω = 3.6 × 1.5/1.2 = 4.5 rad s⁻¹. Ek rises threefold (4.05 J to 12.15 J); the extra comes from work done by the diver's muscles.
- Equations for uniform angular acceleration
- ω = ω₀ + αt θ = (ω₀ + ω)t/2 θ = ω₀t + ½αt² ω² = ω₀² + 2αθ
3.13.2 Wind energy
- Maximum power available from the wind
- P = ½πr²ρv³, where r is the blade length and ρ the air density. Mass per second ρπr²v carries kinetic energy ½mv² per second.
- Wind speed doubles. Effect on the power available?
- P ∝ v³, so it rises by a factor of 8.
- Why can a turbine not extract all the wind's kinetic energy?
- The air must keep moving past the rotor, so it keeps some kinetic energy. There are also friction, turbulence, gearbox and generator losses.
- Why are turbines in a wind farm spaced well apart?
- Behind each turbine is a wind shadow of slower, turbulent air; spacing stops one turbine sitting in another's shadow.
- Advantages and disadvantages of wind power
- For: no fuel, no carbon dioxide in operation, low running cost. Against: intermittent, noise, visual impact, risk to birds and bats, needs a lot of land or sea.
3.13.3 Solar energy
- Intensity at distance r from a point source
- I = P/(4πr²), in W m⁻². I ∝ 1/r², so tripling the distance cuts intensity to one ninth.
- Solar cell V–I characteristic: where is the maximum power?
- Current is nearly constant at low p.d., then falls steeply to zero at the open-circuit voltage. Power IV is zero at both ends and greatest near the knee: calculate IV for each point.
- Solar cells in series and in parallel
- n cells in series: n × the voltage, same current. m branches in parallel: same voltage, m × the current. A series string is limited by its weakest (e.g. shaded) cell.
- Panel of area 1.6 m², 800 W m⁻² at right angles, 17% efficient. Output power?
- Incident power = 800 × 1.6 = 1280 W. Output = 0.17 × 1280 = 218 W.
- Required practical: testing the inverse square law with an LDR
- Small lamp and LDR on a rule in a darkened room; vary d and record resistance, subtracting background. A distance offset to the filament is a systematic error; the LDR may not respond in proportion to intensity.
3.13.4 Hydroelectric power and pumped storage
- Power from water falling through a head h
- P = ρQgh, where Q is the volume flow rate (m³ s⁻¹) and ρ the density of water.
- Energy changes in a hydroelectric station
- Gravitational potential energy of water → kinetic energy of water → kinetic energy of the turbine → electrical energy from the generator.
- Pumped storage: how it works
- Water is pumped to an upper reservoir when demand is low and released through turbines when demand is high. It is an energy store, not a source, and returns less energy than it uses.
- Why do hydroelectric and pumped storage stations suit back-up supply?
- They can start up and reach full output within minutes when demand rises, unlike base-load stations that run continuously.
- Round-trip efficiency of pumped storage with pumping and generating each 85% efficient
- 0.85 × 0.85 = 0.72 (72%).
Revise Energy sources further
- Study guideOxfordAQA International AS and A-level Physics: Rotational motion and angular momentum (9630)
- Revision notesOxfordAQA International AS and A-level Physics: Rotational motion and angular momentum (9630) – Revision Notes
- Practice questionsOxfordAQA International AS and A-level Physics: Rotational motion and angular momentum (9630) – Practice Questions