AQA A-Level Physics (7408): X-ray imaging – Practice Questions

Original AQA A-level Physics 7408 X-ray imaging practice: tube physics and spectra, sharpness and dose, detectors, attenuation calculations and CT scanning.

Subject
Physics
Level
A LEVELS
Topic
Medical physics
Updated

Aligned to AQA A Level Physics (7408), For first teaching 2015. Official specification .

Syllabus page (what it covers and how it is assessed): AQA A Level Physics.

Syllabus points this page covers

7408

  • 3.10.5 X-ray imaging

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (7408).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers from your board or school.

These questions cover section 3.10.5 X-ray imaging of the AQA AS and A-level Physics specification (7407/7408), part of the A-level only Medical physics option. Learn the content first in the X-ray imaging study guide and the X-ray imaging revision notes.

Data: e = 1.60 × 10⁻¹⁹ C; h = 6.63 × 10⁻³⁴ J s; c = 3.00 × 10⁸ m s⁻¹. Attenuation coefficients are illustrative values for practice.

Section A

1. Explain how the continuous part of an X-ray spectrum is produced. [2]

2. An X-ray tube operates at 60 kV. Calculate the maximum photon energy in joules and the minimum wavelength of the X-rays. [3]

3. State one advantage of a flat panel detector compared with photographic film. [1]

4. Explain why a patient is given a barium meal before an X-ray of the stomach. [2]

5. State the purpose of an anti-scatter grid. [1]

6. The half-value thickness of a tissue is 12 mm for an X-ray beam. Calculate the linear attenuation coefficient. [2]

Section B

7. An X-ray tube operates at 120 kV with a tube current of 4.0 mA.

(a) Calculate the power delivered to the anode. [1]
(b) Calculate the number of electrons striking the anode each second. [1]
(c) About 99% of this power heats the anode. Calculate the energy transferred as heat in a 0.50 s exposure. [1]
(d) Explain why the anode is made to rotate. [2]

8. This question is about the spectrum of an X-ray tube with a tungsten target.

(a) Describe the main features of a graph of intensity against photon energy for the beam. [3]
(b) The tube voltage is reduced from 100 kV to 80 kV with the current unchanged. Describe how the graph changes. [2]
(c) Explain why the characteristic lines stay at the same photon energies. [1]

9. For the X-rays used, soft tissue has a half-value thickness of 12 mm and density 1050 kg m⁻³.

(a) Calculate the fraction of the intensity transmitted through 5.0 cm of soft tissue. [2]
(b) Calculate the mass attenuation coefficient of soft tissue. [1]
(c) The half-value thickness of lead for the same beam is 0.10 mm. Calculate the thickness of lead that reduces the intensity to 1.0%. [2]

10. For a different beam, muscle has μ = 20 m⁻¹ and bone has μ = 80 m⁻¹. One beam passes through 6.0 cm of muscle; a second beam passes through 4.5 cm of muscle and 1.5 cm of bone.

(a) Calculate the fraction of intensity transmitted along each path. [3]
(b) Calculate the ratio of the two transmitted intensities and explain how this produces an image of the bone. [2]

11. An X-ray tube has a focal spot 0.60 mm wide. The source-to-object distance is 1.2 m and the object-to-detector distance is 0.30 m.

(a) Calculate the width of the blurred edge of the image. [2]
(b) State two changes that would make the image sharper. [2]

12. This question is about X-ray detection.

(a) Describe how a flat panel detector produces an image. [3]
(b) Explain why an intensifying screen reduces the dose needed when film is used. [2]
(c) State why a fluoroscopic image intensifier is used. [1]

13. (a) Describe the basic principles of a CT scanner. [4] (b) Compare CT with a plain X-ray image in terms of resolution, cost and safety. [3]

Answers

1. Electrons are decelerated in the electric fields of target nuclei [1]; the kinetic energy they lose is emitted as photons with a continuous range of energies up to eV [1]

2. E = eV = 1.60 × 10⁻¹⁹ × 6.0 × 10⁴ = 9.6 × 10⁻¹⁵ J [1]; λ = hc/E = 6.63 × 10⁻³⁴ × 3.00 × 10⁸/9.6 × 10⁻¹⁵ [1]; = 2.1 × 10⁻¹¹ m [1]

3. Any one: image available immediately; digital so it can be stored, sent and enhanced; lower dose; no chemical processing [1]

4. The stomach absorbs X-rays about as much as the tissue around it, so it would barely show [1]; barium is X-ray opaque and coats the stomach lining, increasing contrast so it shows clearly [1]

5. To absorb scattered X-rays so they do not reach the detector and reduce contrast [1]

6. μ = ln 2/x½ = 0.693/0.012 [1]; = 58 m⁻¹ [1]

7. (a) P = VI = 1.2 × 10⁵ × 4.0 × 10⁻³ = 480 W [1]
(b) 4.0 × 10⁻³/1.60 × 10⁻¹⁹ = 2.5 × 10¹⁶ s⁻¹ [1]
(c) 0.99 × 480 × 0.50 = 240 J [1]
(d) The heat is spread over a ring around the rotating anode instead of one spot [1]; so a small focal spot (for sharp images) can be used without melting the target [1]

8. (a) A continuous curve rising from near zero at low energy (low-energy photons absorbed in the tube window or filter) [1]; falling to zero at a maximum energy equal to eV [1]; with sharp characteristic peaks superimposed at particular energies [1]
(b) The maximum photon energy falls from 100 keV to 80 keV [1]; the intensity falls at all energies (the curve is lower) [1]
(c) The line energies equal differences between energy levels of the target atoms, which depend only on the target element [1]

9. (a) Number of half-value thicknesses = 50/12 = 4.17 [1]; fraction = (1/2)^4.17 = 0.056 [1]
(b) μ = 0.693/0.012 = 57.8 m⁻¹; μm = 57.8/1050 = 0.055 m² kg⁻¹ [1]
(c) (1/2)ⁿ = 0.010 gives n = ln 100/ln 2 = 6.64 [1]; thickness = 6.64 × 0.10 = 0.66 mm [1]
Examiner insight: Working in half-value thicknesses avoids finding μ for lead; both routes score if the logarithm is handled correctly.

10. (a) Muscle only: e^(−20 × 0.060) = 0.30 [1]; exponent for the second path = 20 × 0.045 + 80 × 0.015 = 2.1 [1]; e^(−2.1) = 0.12 [1]
(b) Ratio = 0.30/0.12 = 2.5 [1]; less intensity reaches the detector behind the bone, so the bone shows as a light region against darker muscle (differential absorption) [1]

11. (a) By similar triangles, blur = 0.60 × 0.30/1.2 [1]; = 0.15 mm [1]
(b) Any two: use a smaller focal spot; increase the source-to-patient distance; place the patient closer to the detector; keep the patient still or use a shorter exposure [2]

12. (a) An X-ray scintillator converts X-ray photons into visible light [1]; an array of photodiode pixels converts the light into electric charge [1]; the pixels are read by electronic scanning to build a digital image [1]
(b) Film is much more sensitive to light than to X-rays [1]; the screen’s phosphor emits many light photons for each X-ray absorbed, so fewer X-rays (less dose) are needed for the same exposure [1]
(c) To give bright, real-time (moving) images, for example during a procedure [1]

13. (a) The X-ray tube rotates around the patient [1]; it produces a narrow, monochromatic beam [1]; an array of detectors measures the transmitted intensity at many angles [1]; a computer processes the signals to produce cross-sectional images that can be combined in 3D [1]
(b) Resolution: CT gives higher resolution and better soft-tissue contrast, and 3D images [1]; cost: CT is much more expensive [1]; safety: CT gives the patient a much higher dose [1]

Where marks are usually lost

  • Saying the tube current changes the maximum photon energy.
  • Using log instead of ln with half-value thickness.
  • Leaving mm and m⁻¹ mixed in the exponent.
  • Describing the filter as reducing the intensity of all photons equally.
  • Describing CT without naming the computer processing.

More on this topic

Official syllabus

AQA AS and A-level Physics specification (7407/7408), AS and A-level exams June 2016 onwards: section 3.10.5 X-ray imaging (A-level only).

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.