Cambridge A Level Information Technology (9626): Disaster recovery management – Practice Questions
Thirteen original Cambridge 9626 IT section 14.10 questions with answers on risk analysis, quantifying risk, backups and disaster recovery strategies.
- Subject
- ICT
- Level
- A LEVEL
- Topic
- Topic 14 – Communications technology
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Harris Khan (what this means)
Aligned to Cambridge A Level Information Technology (9626), 2025-2027. Official specification .
Syllabus page (what it covers and how it is assessed): Cambridge A Level Information Technology.
Syllabus points this page covers
9626 (A Level)
- 14.10 Disaster recovery management
This page covers 1 of the 10 subtopics in topic 14, Communications technology.
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Information Technology (9626).
These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs; examination boards hold copyright in their own papers. Use these alongside the official past papers available free from your board.
Related: Disaster recovery management study guide | Communications technology revision notes
These questions are for section 14.10 Disaster recovery management (Topic 14, A Level) of Cambridge International AS & A Level Information Technology (9626), 2025–2027. All organisations and figures are invented.
Section A
1. Give three types of disaster that can cause data loss. [3]
2. Describe what is meant by risk analysis. [2]
3. Explain the purpose of perpetrator analysis. [2]
4. State the purpose of an uninterruptible power supply. [2]
5. Distinguish between an incremental backup and a differential backup. [2]
Section B
6. Lakeside Printing has assessed three risks.
| Risk | Cost of one incident | Expected number per year |
|---|---|---|
| Fire | £80,000 | 0.01 |
| Power cut | £5,000 | 0.5 |
| Malware attack | £30,000 | 0.2 |
(a) Calculate the expected yearly loss for each risk. [3]
(b) State which risk should be dealt with first and give a reason. [2]
(c) A protection costs £2,000 a year and would remove the malware risk entirely. State whether it is worth buying, with a calculation. [2]
7. A server room uses a UPS with 900 watt-hours of stored energy, of which 75% is usable. The equipment uses 450 watts.
(a) Calculate how long the UPS can supply power, in hours. [3]
(b) State why this is not enough on its own for a long power cut, and what else is needed. [2]
8. A full backup of 400 GB is made on Sunday. Each day from Monday to Friday, 15 GB of data is added.
(a) Calculate the storage used by the end of Friday if incremental backups are made each day. [2]
(b) Calculate the storage used by the end of Friday if differential backups are made each day. [3]
(c) State how many backup sets are needed to restore on Friday evening for each type. [2]
(d) Explain one advantage of each type. [2]
9. An online shop earns £1,800 an hour. A failure stops the site for 8 hours. Calculate the income lost and state one other cost to the shop. [2]
10. Explain why backup copies should be tested and kept off-site. [4]
11. Describe the contents of a disaster recovery plan. [6]
12. A hospital must restore its patient record system within 2 hours of a failure and lose no more than 15 minutes of data. Explain what recovery time and recovery point measures are, and describe how the hospital could meet these targets. [6]
13. A small company in a flood-prone area asks you to advise on reducing the risk to its data. Evaluate the measures it should take. [6]
Answers
1. Any three from: natural disaster such as a flood or fire [1]; equipment or power failure [1]; cybercrime such as hacking or ransomware [1]; malware [1]; criminal activity such as theft [1]; accidental events such as deleting files [1]. [3]
2. Identifying what could go wrong [1] and estimating how likely each threat is and how serious its effect would be, so that the most serious risks are tackled first [1]. [2]
3. To find out who might carry out a deliberate attack and why, such as a criminal, a competitor or an employee [1], so that defences can be matched to the way they are likely to work and what they may target [1]. [2]
4. It supplies power from a battery [1] when the mains fails, giving time to save work and shut down safely, or until a generator starts [1]. [2]
5. An incremental backup copies only data changed since the last backup of any type [1]; a differential backup copies all data changed since the last full backup [1]. [2]
6. (a) Fire: 80,000 × 0.01 = £800 [1]. Power cut: 5,000 × 0.5 = £2,500 [1]. Malware: 30,000 × 0.2 = £6,000 [1].
(b) Malware [1], because it has the highest expected yearly loss [1].
(c) The loss prevented is £6,000, which is more than the £2,000 cost [1], so it is worth buying, saving £4,000 a year [1].
7. (a) Usable energy = 900 × 0.75 = 675 watt-hours [1]; time = 675 ÷ 450 [1] = 1.5 hours [1].
(b) A UPS has limited battery capacity [1], so a generator is needed for a long outage [1].
8. (a) 400 + (5 × 15) [1] = 475 GB [1].
(b) Differential backups: 15, 30, 45, 60, 75 = 225 GB [1][1]; 400 + 225 = 625 GB [1].
(c) Incremental: the full backup and 5 incrementals, which is 6 sets [1]. Differential: the full backup and the latest differential, which is 2 sets [1].
(d) Incremental: uses less storage and is quicker to make [1]. Differential: quicker and simpler to restore, with fewer sets needed [1].
9. 8 × 1,800 = £14,400 [1]. Other cost, for example: repair costs, loss of customer trust, or staff overtime [1]. [2]
10. A backup that has never been restored may not work or may be incomplete [1], so testing proves that data can be recovered and shows problems before a real disaster [1]. If backups are kept in the same place as the original, a fire or flood would destroy both [1], so a copy kept off-site, or in the cloud, survives [1]. [4]
11. Any six from: a named team with roles and contact details [1]; a list of systems in order of priority to restore [1]; where and how backups are stored and restored [1]; alternative premises and equipment, such as a hot or warm site [1]; steps to take for each type of disaster [1]; how to communicate with staff, customers and suppliers [1]; the recovery time and recovery point targets [1]; a schedule for testing and updating the plan [1]. [6]
12. Recovery time objective: the longest time the system can be unavailable, here 2 hours [1]. Recovery point objective: the longest period of data that can be lost, here 15 minutes [1]. To meet the data target, back up or replicate data at least every 15 minutes [1] to a second server in a different place [1]. To meet the time target, keep a standby system ready to take over (a hot site) [1], with a tested plan and trained staff [1]. Maximum 6 marks. [6]
13. Keep backups off-site, or in the cloud, so a flood does not destroy them [1]; move servers to an upper floor or a raised, waterproof room [1]; use a UPS and generator in case flooding cuts the power [1]; have a plan for an alternative location from which staff can work [1]; test restoring from backups regularly [1]; also protect from other threats such as malware, with anti-malware and access controls [1]. Evaluation: off-site backups are the cheapest and most valuable measure [1], while moving the room costs more but removes the risk to hardware [1]. Maximum 6 marks. [6]
Where marks are usually lost
- Giving a list of disasters without any link to data loss.
- Quantifying risk by cost only, ignoring the probability.
- Mixing up incremental and differential backups.
- Ignoring testing and off-site storage of backups.
- Writing “have a plan” without saying what the plan contains.
Related resources
-
Study guides
Cambridge A Level Information Technology (9626): Mobile communication systems
Cambridge 9626 IT section 14.8 study guide: cellular network structure, 3G, 4G and 5G, and satellite systems including GPS, mapping, surveillance and broadcasting.
ICT · Cambridge · A Level
Read guide -
Practice questions
Cambridge A Level Information Technology (9626): Mobile communication systems – Practice Questions
Thirteen original Cambridge 9626 IT section 14.8 questions with answers on cellular networks, 3G, 4G and 5G, satellites, GPS and broadcasting.
ICT · Cambridge · A Level
Try questions -
Study guides
Cambridge A Level Information Technology (9626): Network protocols
Cambridge 9626 IT section 14.6 study guide: protocols, packet, circuit and message switching, MAC and IP addressing, routing, TCP/IP and OSI layers and firewalls.
ICT · Cambridge · A Level
Read guide
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.