Skip to content
Marlbridge

Revision Notes

Cambridge A Level Physics (9702): Electromagnetic induction – Revision Notes

Revision notes for Cambridge A Level Physics 9702 20.5 Electromagnetic induction: flux, flux linkage, Faraday and Lenz, exam traps and a self-test.

Subject
Physics
Level
A LEVEL
Topic
Magnetic fields
Updated

Aligned to Cambridge A Level Physics (9702), 2025-2027. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge A Level Physics.

Syllabus points this page covers

9702 (A Level)

  • 20.5 Electromagnetic induction

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (9702).

Subtopic 20.5 of Cambridge International AS & A Level Physics 9702 (2025–2027) covers the definition of magnetic flux, Φ = BA, flux linkage, the experiments that demonstrate electromagnetic induction, and Faraday’s and Lenz’s laws. These notes are condensed for recall. For full explanations and worked examples, read the Electromagnetic induction study guide; to apply the ideas, try the Electromagnetic induction practice questions.

Definitions and equations

Magnetic flux: the product of the magnetic flux density and the cross-sectional area perpendicular to the direction of the magnetic flux density.

Φ = BA                 (A ⊥ B)          unit: weber, 1 Wb = 1 T m²
Φ = BA cos θ           (θ between B and the normal to the coil)
Flux linkage = NΦ      unit: Wb (Wb-turns)
E = −Δ(NΦ)/Δt          (Faraday: size; minus sign: Lenz)
E = BLv                (rod of length L moving at v ⊥ B)

The two laws

  • Faraday’s law: the induced e.m.f. is proportional to the rate of change of magnetic flux linkage.
  • Lenz’s law: the induced e.m.f. is in such a direction as to oppose the change producing it.
  • Lenz’s law follows from conservation of energy: work must be done against the opposing effect, and that work becomes electrical energy.

Orientation of a coil

Coil position Flux linkage
Plane ⊥ B NBA (maximum)
Plane at angle α to B NBA sin α
Plane parallel to B 0
Turned 180° from ⊥ −NBA (change of 2NBA)

Graph rules

Flux linkage–time graph E.m.f.
Rising straight line Constant, one sign
Flat Zero
Falling straight line Constant, opposite sign
Steeper Larger
Area under E–t graph Change in flux linkage

Experiments: what they show

Observation Shows
Meter deflects only while a magnet moves in or out of a coil A changing flux induces an e.m.f.
Deflection reverses when the motion reverses Direction depends on the direction of the change
Switching a current on or off in a second coil gives a brief deflection Changing flux induces e.m.f. even without motion
Faster motion, stronger magnet, more turns → larger deflection Size depends on the rate of change of flux linkage
Approaching N pole makes the near end of the coil a N pole Lenz’s law: the induced effect opposes the change
Magnet falls slowly through a copper tube Induced currents oppose the motion

Lenz’s law direction method

  1. Is the flux through the circuit increasing or decreasing, and which way does it point?
  2. Induced field opposes the change: opposite to the external field if increasing, same way if decreasing.
  3. Right-hand grip rule → current direction.
  4. Check: any force on the conductor opposes its motion.

Key terms

Term Meaning
Magnetic flux Φ BA with A perpendicular to B; unit weber
Weber 1 T m²
Flux linkage NΦ for a coil of N turns
Induced e.m.f. E.m.f. produced by a changing flux linkage
Faraday’s law E.m.f. ∝ rate of change of flux linkage
Lenz’s law Induced e.m.f. opposes the change producing it

Exam traps

  • Using the whole area of a coil tilted to the field.
  • Leaving out N.
  • Treating a 180° rotation as no change.
  • Linking a large e.m.f. to a large flux rather than a fast change.
  • Converting cm² to m² by dividing by 100 (it is 10⁴).
  • Stating Lenz’s law as opposing the flux rather than the change.
  • Saying there is no e.m.f. in an open circuit: the e.m.f. is induced; only the current needs a complete circuit.

Self-test

  1. Define magnetic flux.
  2. State the unit of flux in terms of the tesla.
  3. A coil of 500 turns and area 3.0 × 10⁻⁴ m² has its plane perpendicular to a 0.080 T field. Calculate the flux linkage.
  4. The field in Question 3 falls to zero in 0.15 s. Calculate the average e.m.f.
  5. A flat loop of area 1.5 × 10⁻³ m² has its normal at 60° to a field of 0.12 T. Calculate the flux.
  6. State Faraday’s law.
  7. State Lenz’s law and the conservation law it follows from.
  8. A rod 0.15 m long moves at 5.0 m s⁻¹ perpendicular to a 0.40 T field. Calculate the e.m.f.
  9. A graph of flux linkage against time is horizontal for 2 s. What is the e.m.f. during that time?
  10. A coil is turned through 180° in a uniform field. Is the change in flux linkage zero? Explain.
  11. Why does a magnet take longer to fall through a copper tube than through a plastic tube?
  12. A north pole is pulled away from one end of a coil. What polarity does the induced current give that end?

Answers: 1. The product of the magnetic flux density and the cross-sectional area perpendicular to the field. 2. 1 Wb = 1 T m². 3. 500 × 0.080 × 3.0 × 10⁻⁴ = 0.012 Wb. 4. 0.012 / 0.15 = 0.080 V. 5. 0.12 × 1.5 × 10⁻³ × cos 60° = 9.0 × 10⁻⁵ Wb. 6. The magnitude of the induced e.m.f. is proportional to the rate of change of magnetic flux linkage. 7. The induced e.m.f. acts in a direction to oppose the change producing it; conservation of energy. 8. BLv = 0.40 × 0.15 × 5.0 = 0.30 V. 9. Zero. 10. No: the flux passes through the coil the other way, so the linkage goes from +NBA to −NBA, a change of 2NBA. 11. The moving magnet induces currents in the copper; by Lenz’s law these produce fields that oppose its motion. Plastic is an insulator, so no current flows. 12. South (it attracts the magnet, opposing its withdrawal).

More resources on this topic

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.