Edexcel International A Level Physics (YPH11): Unit 3 Implementation and Measurements – Practice Questions

Twelve original questions on checking an inexperienced student's experiment, with mark-scheme answers, for Edexcel IAL Physics Unit 3 section 3.4.

Subject
Physics
Level
A LEVELS
Topic
Unit 3: Practical Skills in Physics I
Updated

Aligned to Pearson Edexcel A Level Physics (YPH11), Issue 3. Official specification .

Syllabus page (what it covers and how it is assessed): Pearson Edexcel A Level Physics.

Syllabus points this page covers

YPH11

  • 3.4 Implementation and measurements

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (YPH11).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers available free from your board.

Related: Unit 3 implementation and measurements study guide | Unit 3 implementation and measurements revision notes

These questions cover section 3.4 Implementation and measurements of Unit 3: Practical Skills in Physics I, Pearson Edexcel IAL Physics (YPH11), Issue 3. In each question you are checking the work of an inexperienced student.

Section A

1. A micrometer measuring a wire shows 1 mm on the sleeve with the half-millimetre mark visible, and the thimble reads 09. With the jaws closed it read +0.01 mm. State the diameter of the wire. [2]

2. On Vernier calipers measuring a rod, the main-scale reading just before the Vernier zero is 12 mm and the seventh Vernier mark lines up with a main-scale mark. State the reading to the correct number of significant figures and its uncertainty. [2]

3. A student times three repeats with a stopwatch reading to 0.01 s and records 3.4 s, 3.42 s and 3.5 s. Comment on the way the times are recorded. [2]

4. A student measures the resistance of a wire at lengths of 0.20 m, 0.25 m, 0.30 m and 0.35 m, using a wire 1.00 m long. Comment on the number and the range of readings. [3]

5. Explain how a set square improves the measurement of the extension of a spring. [2]

6. State what a student should do on finding a reading that is inconsistent with the others. [2]

Section B

7. A student hangs loads on a copper wire 1.5 m long and measures its extension by reading a pointer against a metre rule.

Load / N 10 20 30 40 50
Extension / mm 0.5 1.0 1.6 2.0 2.5

(a) Comment on the precision with which the extensions are recorded. [2]
(b) Calculate the percentage uncertainty in the 2.5 mm reading. [2]
(c) Identify the inconsistent reading, with a reason. [2]
(d) Suggest two improvements, using additional apparatus or a change of method, and explain each. [4]

8. A student releases a trolley from rest at distances s from a marker at the bottom of a ramp, and times each run once by hand with a stopwatch.

s / m 0.2 0.40 0.60 0.80 1.00
t / s 1.13 1.6 1.96 2.46 2.53

(a) Comment on the significant figures in the table. [2]
(b) For uniform acceleration from rest, s = ½at². Use s/t² to show which reading is inconsistent, and state the time expected for that distance. [3]
(c) Suggest two improvements to the method, with reasons. [4]

9. A student measures a wire’s diameter once, near one end, with a micrometer. The sleeve shows 0 mm with the half-millimetre mark visible, and the thimble reads 32. The student records “0.32 mm”.

(a) Give the correct reading and explain the student’s error. [2]
(b) Comment on taking a single reading and suggest how the measurement should be made. [3]

10. To find the wavelength of laser light, a student shines the laser through a diffraction grating onto a wall. She measures, once, the distance from the central spot to the first-order spot on the left with a 30 cm ruler, and the grating-to-wall distance by laying the same ruler end to end several times. Comment on her measurements and suggest improvements. [6]

11. A student investigating the I–V characteristic of a 12 V filament lamp takes readings at 0.5 V, 1.0 V, 1.5 V, 2.0 V and 3.0 V.

(a) Comment on the range and number of readings. [3]
(b) Explain why the readings at low p.d. alone could mislead the student about the lamp’s behaviour. [2]

12. To find the speed of sound, a student uses a signal generator at 2.00 kHz, a loudspeaker, a microphone and an oscilloscope. She moves the microphone until the traces are in phase, moves it on to the next in-phase position, and measures the distance between the two positions as 0.17 m with a metre rule. She calculates v = fλ = 340 m s⁻¹. Comment on her method and suggest two improvements. [6]

Answers

1. 1 + 0.5 + 0.09 = 1.59 mm [1]; corrected for zero error 1.59 − 0.01 = 1.58 mm [1]. [2]

2. 12.7 mm [1]; uncertainty half the resolution, 0.05 mm [1]. [2]

3. The times are not recorded to a consistent number of decimal places [1]; all should be to 0.01 s (3.40 s, 3.42 s, 3.50 s), although reaction time means the real uncertainty is larger than 0.01 s [1]. [2]

4. Four values are too few to draw a reliable line or spot an anomaly; take at least six [1]. The range 0.20–0.35 m uses only a small part of the 1.00 m wire [1], so extend it to about 0.10–0.90 m to reduce the uncertainty in the gradient [1]. [3]

5. The set square, placed on the bench against the rule, checks that the rule is vertical [1], so each extension is measured along the line of the spring and not along a tilted scale [1]. [2]

6. Check the calculation or recording [1], then repeat the measurement; exclude it only if a reason is found [1]. [2]

7. (a) A metre rule resolves only 1 mm [1], so recording extensions to 0.1 mm claims a precision the instrument cannot give [1].
(b) Uncertainty 0.5 mm [1]; 0.5 ÷ 2.5 × 100% = 20% [1].
(c) 1.6 mm at 30 N [1]: the other readings give 0.050 mm per newton, so 1.5 mm is expected [1].
(d) Use a Vernier scale attached to a reference wire, or a travelling microscope, to read the extension [1], because it resolves 0.1 mm or better, cutting the percentage uncertainty [1]. Use a longer wire, for example 3 m along the bench over a pulley [1], because the extension is proportional to length, so it becomes larger and its percentage uncertainty smaller [1]. [10]

8. (a) The distance 0.2 m should be 0.200 m to match the others [1]; the time 1.6 s should be recorded to two decimal places like the others [1].
(b) s/t² is 0.156 m s⁻² for 0.2, 0.40, 0.60 and 1.00 m [1] but 0.80 ÷ 2.46² = 0.132 m s⁻² at 0.80 m, so this reading is inconsistent [1]. Expected t = √(0.80 ÷ 0.156) = 2.26 s [1].
(c) Use light gates at the release point and at the marker, connected to an electronic timer, instead of hand timing [1], removing reaction-time error, which is large for times of 1–3 s [1]. Repeat each run at least three times and use the mean [1], so random variation in release and timing is reduced [1]. [9]
Examiner insight: Showing the ratio for every row is what turns “looks wrong” into a creditworthy identification.

9. (a) Reading 0 + 0.5 + 0.32 = 0.82 mm [1]; the student missed the half-millimetre mark on the sleeve [1].
(b) A single reading cannot show whether the wire is uniform or circular [1]. Measure at several places along the wire [1], rotating it through 90° at each place, and take the mean, quoting half the range as the uncertainty [1]. [5]

10. One reading on one side only gives no check on random error [1]; measure between the first-order spots on both sides and halve the distance [1]. A 30 cm ruler laid end to end adds an uncertainty at each step [1]; use a metre rule or tape measure for the grating-to-wall distance [1]. Use the second and higher orders as well [1], since larger distances have smaller percentage uncertainties and give a mean wavelength [1]. [6]

11. (a) The range is too small: readings reach only 3.0 V of the lamp’s 12 V rating [1]. Extend to about 12 V [1] with at least ten readings, spaced roughly every 1 V [1].
(b) At low p.d. the filament stays cool, so the I–V graph is nearly straight [1]; the curve, caused by resistance rising as the filament heats, only appears at higher p.d. [1]. [5]

12. Measuring one wavelength gives a large percentage uncertainty: 0.5 mm in 170 mm is small, but judging the in-phase positions adds several millimetres [1], so the uncertainty in λ is large [1]. Improvement: move through several wavelengths, for example five, and divide the total distance by five [1], which reduces the percentage uncertainty [1]. Improvement: repeat at several frequencies and plot λ against 1/f [1]; the gradient gives v and averages out random error [1]. [6]

Where marks are usually lost

  • Identifying an anomaly by eye with no calculation.
  • Forgetting the half-millimetre mark on a micrometer.
  • Suggesting “more readings” without saying how many or over what range.
  • Giving an improvement with no reason.
  • Treating the stopwatch’s display resolution as the timing uncertainty.

Official syllabus

Pearson Edexcel International Advanced Subsidiary/Advanced Level in Physics, Issue 3, Unit 3, section 3.4 Implementation and measurements.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.