Skip to content
Marlbridge

Practice Questions

OCR A Level Biology A (H420): Evaluation – Practice Questions

Twelve original questions on anomalies, limitations, precision, accuracy, percentage error and improving experiments for OCR A Level Biology A 1.1.4 Evaluation.

Subject
Biology
Level
A LEVELS
Topic
Development of practical skills in biology
Updated

Aligned to OCR A Level Biology (H420), Version 4.1 (April 2026), for first assessment in 2025. Official specification .

Syllabus page (what it covers and how it is assessed): OCR A Level Biology.

Syllabus points this page covers

H420

  • 1.1.4 Evaluation

This page covers 1 of the 8 subtopics in topic 1, Development of practical skills in biology.

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Biology (H420).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers from your board or school.

These questions cover learning outcomes 1.1.4(a) to (e) of the OCR A Level Biology A specification (H420), Version 4.1 (April 2026), first assessment 2025. Questions 2, 4 and 5 practise calculations linked to this section. All contexts and data are invented for practice. Where percentage error is asked for, use percentage error = 2 × absolute uncertainty ÷ quantity measured × 100 %, taking the absolute uncertainty as half the smallest division.

Related: evaluation study guide and evaluation revision notes.

Section A

1. A student measures the volume of oxygen released by a catalase reaction in 2 minutes. Three repeats at 30 °C give 8.0, 8.5 and 12.5 cm³. Identify the anomalous result and suggest one possible cause. [2]

2. Calculate the mean volume in question 1, first with and then without the anomalous result. State which mean should be used and why. [3]

3. Explain the difference between the precision and the accuracy of a set of measurements. [2]

4. A measuring cylinder with 1 cm³ divisions is used to measure 8 cm³ of solution.

(a) Calculate the percentage error. [2]

(b) A syringe reading to 0.1 cm³ is used to measure the same volume. Calculate the percentage error and state what the comparison shows. [2]

5. A potato cylinder is weighed on a balance reading to 0.01 g before and after being left in a solution. Its mass is 6.40 g before and 5.92 g after.

(a) Calculate the change in mass and its uncertainty. [2]

(b) Calculate the percentage error in the change in mass. [1]

6. A thermometer in a water bath always reads 2 °C higher than the true temperature. State the type of error and explain why taking repeat readings does not remove it. [2]

Section B

7. The table shows the mean rate of an enzyme reaction, with the standard deviation of three repeats, at four temperatures.

Temperature / °C Mean rate / cm³ min⁻¹ Standard deviation
20 4.2 0.1
30 8.2 0.2
40 16.2 0.3
50 10.7 0.3

Evaluate how far the data support the conclusion that the optimum temperature of the enzyme is 40 °C. [4]

8. A student investigates the effect of temperature on the time taken for the colour of a solution to disappear. Tubes are placed in a beaker of water heated on a hotplate. The student decides when the colour has gone by looking at the tube and times it with a stopwatch. Only one tube is used at each of three temperatures.

Identify three limitations of this method and explain the effect of each on the results. [6]

9. For each of the following weaknesses, suggest a specific improvement.

(a) Gas is collected over water in a measuring cylinder that has 1 cm³ divisions, and the volumes are small. [1]

(b) The end point is judged by eye. [1]

(c) The tissue pieces are cut with a knife and vary in size. [1]

(d) The optimum lies somewhere between 30 and 50 °C but only 30, 40 and 50 °C were tested. [1]

10. A student concludes from an investigation at 20, 30 and 40 °C that “enzyme activity keeps increasing as temperature rises”. Evaluate this conclusion. [2]

11. Explain why measuring a larger change in mass reduces the percentage error in the change. [2]

12. A student states that the results of an experiment are “reliable because the experiment was repeated three times”. Evaluate this statement. [2]


Answers

How these answers work. Marking points are shown in brackets. The mark total for each question is the sum of the points. Alternative wording that carries the same meaning is credited.

1. 12.5 cm³ is the anomalous result, because it is far from the other two [1]. Any one cause [1]: an air bubble in the syringe; a timing error; a different piece of tissue; extra enzyme or substrate added; the temperature of the water bath was higher. [2]

2. With the anomaly: (8.0 + 8.5 + 12.5) ÷ 3 = 9.7 cm³ [1]. Without it: (8.0 + 8.5) ÷ 2 = 8.25 cm³ [1]. The mean without the anomaly should be used, because the anomalous value does not fit the pattern and probably has a cause, or the measurement should be repeated [1]. [3]

3. Precision is how close repeated measurements are to one another [1]. Accuracy is how close a measurement is to the true value [1]. [2]

4. (a) Absolute uncertainty = ±0.5 cm³ [1]. Percentage error = 2 × 0.5 ÷ 8 × 100 = 12.5 % [1].

(b) Absolute uncertainty = ±0.05 cm³; percentage error = 2 × 0.05 ÷ 8 × 100 = 1.25 % [1]. The syringe has a smaller percentage error, so it gives a more precise volume [1]. [4]

5. (a) Change = 6.40 − 5.92 = 0.48 g [1]. Uncertainty = 0.005 + 0.005 = ±0.01 g [1].

(b) 0.01 ÷ 0.48 × 100 = 2.1 % [1]. [3]

6. A systematic error [1]. Every reading is shifted by the same amount in the same direction, so repeating and taking a mean gives the same shift; the thermometer must be calibrated or replaced [1]. [2]

7. Any four [1 each]: the mean rate increases from 4.2 to 16.2 cm³ min⁻¹ between 20 and 40 °C and then falls to 10.7 at 50 °C, so the highest rate is at 40 °C [1]; the standard deviations are small (0.1 to 0.3) compared with the differences between the means, so the repeats are precise and the differences are probably real [1]; the temperatures are 10 °C apart, so the true optimum could be anywhere between 30 and 50 °C [1]; so the data support a peak near 40 °C but do not prove 40 °C exactly [1]; more temperatures, such as 35 and 45 °C, are needed [1]. [4]

8. Any three limitations, each with an effect [1 + 1]. Water on a hotplate: the temperature drifts, so the reaction is not carried out at the stated temperature [2]. The end point is judged by eye: it is subjective, so times vary between observers and repeats [2]. One tube at each temperature: there are no repeats, so no mean can be calculated and anomalies cannot be identified [2]. Only three temperatures: a trend and an optimum cannot be located [2]. The tubes were not pre-warmed or the temperature was not monitored: the reaction starts at the wrong temperature [2]. [6]

9. (a) Use a gas syringe, which reads to 0.1 cm³ [1]. (b) Use a colorimeter to measure absorbance against time, or compare the colour with a standard colour chart [1]. (c) Use a cork borer and a ruler, or cut pieces to the same mass or length [1]. (d) Add temperatures at 35 and 45 °C, in a thermostatically controlled water bath [1]. [4]

10. The data cover only 20 to 40 °C, so the conclusion cannot be extended to higher temperatures [1]. Above the optimum, enzymes denature and the rate falls, so the statement is not true for all temperatures [1]. [2]

11. The uncertainty of each balance reading stays the same, so the uncertainty in the change is the same [1]. A larger change makes the percentage error (uncertainty ÷ change) smaller [1]. [2]

12. Repeating three times allows a mean to be calculated and anomalies to be seen [1], but “reliable” needs the repeats to agree closely (low standard deviation) and the method to be valid; three repeats do not remove a systematic error [1]. [2]


Where marks are usually lost

  • Question 1: stating a cause but not identifying the result.
  • Question 2: removing the anomaly without saying why.
  • Question 3: mixing up precision and accuracy.
  • Question 4: forgetting the factor of 2 in the formula, or using the full division as the uncertainty.
  • Question 5: forgetting that the uncertainties of two readings add.
  • Question 7: stating the optimum is exactly 40 °C.
  • Question 8: giving a limitation with no effect.
  • Question 9: suggesting “use a better measuring device” without naming it.

Frequently asked questions

Do I have to use the formula with the factor of 2 for percentage error? The specification gives that form. Use it in questions that ask for a percentage error, and show the substitution.

How many limitations should I give? As many as the marks allow. A six-mark question usually wants three limitations, each with an effect.

Official syllabus

OCR Level 3 Advanced GCE in Biology A (H420), Version 4.1 (April 2026), first assessment 2025. Module 1, Development of practical skills in biology: 1.1.4 Evaluation, learning outcomes (a) to (e).

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.