Skip to content
Marlbridge

Revision Notes

OCR A Level Biology A (H420): Implementing – Revision Notes

Condensed notes on correct use of apparatus, units and conversions, rate units and building data tables for OCR A Level Biology A 1.1.2 Implementing.

Subject
Biology
Level
A LEVELS
Topic
Development of practical skills in biology
Updated

Aligned to OCR A Level Biology (H420), Version 4.1 (April 2026), for first assessment in 2025. Official specification .

Syllabus page (what it covers and how it is assessed): OCR A Level Biology.

Syllabus points this page covers

H420

  • 1.1.2 Implementing

This page covers 1 of the 8 subtopics in topic 1, Development of practical skills in biology.

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Biology (H420).

These notes condense learning outcomes 1.1.2(a) to (c) of the OCR A Level Biology A specification (H420, Version 4.1, April 2026, first assessment 2025). For explanations and worked examples, read the implementing study guide, then test yourself with the implementing practice questions. The whole module is summarised in the planning, implementing, analysing and evaluating revision notes.

Key definitions

Term Meaning
Resolution The smallest change in a quantity that an instrument can show
Meniscus The curved surface of a liquid in a tube
Tare (zero) Setting a balance to read zero with the empty container on it
Blank A sample without the substance being measured, used to set a colorimeter to zero
Qualitative Recorded as a description, such as a colour
Quantitative Recorded as a number with a unit
Rate Change in a quantity divided by the time taken
Raw data Measurements as they were first recorded
Calibration Checking or setting an instrument against a known standard

Outcome map

Outcome Skill
1.1.2(a) Use apparatus and techniques correctly
1.1.2(b) Use appropriate units (M0.1)
1.1.2(c) Present observations and data in an appropriate format

Correct use of apparatus: 1.1.2(a)

Apparatus Key point
Measuring cylinder, pipette, burette Eye level with the bottom of the meniscus
Syringe Remove air bubbles; read at the right mark
Balance Tare with the container; blot tissue dry first
Thermometer Bulb in the liquid, wait for a steady reading
Water bath Allow time for tubes to reach the water temperature
Stopwatch Define the start and the end point clearly
pH meter Calibrate with buffers; rinse the probe between samples
Colorimeter Zero with a blank; same cuvette; correct filter
Gas syringe Check for leaks and a free plunger

Safe use: identify the hazard, assess the risk, control it. Examples: eye protection for acids, alkalis and hydrogen peroxide; a cutting tile for blades; careful handling of hot water; washing hands after handling biological material.

Units: 1.1.2(b)

Quantity Unit
Length of a cell μm or mm
Volume cm³ or dm³
Mass g or mg
Time s or min
Concentration mol dm⁻³
Rate of gas production cm³ min⁻¹
Temperature °C

Conversion factors

From To Operation
mm μm × 1000
μm mm ÷ 1000
cm³ mm³ × 1000
dm³ cm³ × 1000
g mg × 1000
min s × 60

Check: a smaller unit gives a bigger number.

Standard form: 0.0050 mol dm⁻³ = 5.0 × 10⁻³ mol dm⁻³. Keep the same number of significant figures.

Rates:

  • Rate = change in quantity ÷ time.
  • 28 cm³ in 4.0 min is 7.0 cm³ min⁻¹.
  • A rate based on time uses 1 ÷ time. A reaction taking 20 s is faster than one taking 40 s.
  • Potometer: bubble moves 36 mm in 3.0 min in a capillary of radius 0.5 mm. Volume = π × 0.5² × 36 = 28.3 mm³, so the rate is 9.4 mm³ min⁻¹ (0.0094 cm³ min⁻¹).

Recording data: 1.1.2(c)

Observations

  • Be exact: “brick-red precipitate”, not “it changed”.
  • Record colour at the start and at the end.
  • Note the time of any change.

Tables

  1. Ruled lines.
  2. Independent variable in the first column.
  3. Quantity and unit in the column headings, not in the cells.
  4. Same number of decimal places down a column, matching the instrument.
  5. Columns for repeats and for the mean.
Temperature / °C Volume of oxygen / cm³ Mean / cm³
Repeat 1 Repeat 2 Repeat 3
20 8.0 8.5 9.0 8.5
30 14.5 15.0 14.5 14.7

Decimal places

  • Balance to 0.01 g: write 2.40 g, not 2.4 g.
  • Measuring cylinder in 1 cm³ divisions: estimate to 0.5 cm³.
  • Means: no more significant figures than the least precise raw data support.

Quick chains

  • 0.25 mm → 250 μm.
  • 3.5 cm³ → 3500 mm³.
  • 5 mg → 0.005 g.
  • 45 s → 0.75 min.
  • 2.4 dm³ → 2400 cm³.
  • 12 mL = 12 cm³.

Exam traps

  • A number with no unit.
  • A unit written in every cell instead of the column heading.
  • Reading the top of the meniscus.
  • Forgetting to tare a balance or to blot tissue.
  • Converting the wrong way round.
  • Using time as a rate.
  • Writing 2.4 g for a reading of 2.40 g.
  • Describing a colour change as “it went darker” without saying what colour.

Self-test

  1. Where should your eye be when reading a liquid in a measuring cylinder?
  2. Convert 0.18 mm to μm.
  3. Convert 2.5 dm³ to cm³.
  4. Convert 90 s to minutes.
  5. A balance reads to 0.01 g. A potato cylinder has a mass of 3.10 g. How should this mass be written?
  6. 15 cm³ of gas is collected in 2.5 minutes. Calculate the rate and give the unit.
  7. Which should be in the first column of a results table: the independent or the dependent variable?
  8. Why is a colorimeter set to zero with a blank?
  9. Write 0.0040 mol dm⁻³ in standard form.
  10. A reaction takes 25 s. State the rate in s⁻¹.

Answers

  1. Level with the bottom of the meniscus.
  2. 0.18 × 1000 = 180 μm.
  3. 2.5 × 1000 = 2500 cm³.
  4. 90 ÷ 60 = 1.5 min.
  5. 3.10 g (two decimal places).
  6. 15 ÷ 2.5 = 6.0 cm³ min⁻¹.
  7. The independent variable.
  8. So that absorbance from the solvent or cuvette is not included in the reading.
  9. 4.0 × 10⁻³ mol dm⁻³.
  10. 1 ÷ 25 = 0.040 s⁻¹.

Frequently asked questions

Do I need to write units in the table cells? No. Put the quantity and the unit in the column heading, for example “Mass / g”, and write numbers only in the cells.

How many decimal places should I use for raw data? The number the instrument supports. A balance reading to 0.01 g gives two decimal places. A mean can be given to one more decimal place than the raw data.

What counts as a good observation? A specific description of what you see that another person could check, such as “the solution changed from blue to brick-red after 90 s”.

Official syllabus

OCR Level 3 Advanced GCE in Biology A (H420), Version 4.1 (April 2026), first assessment 2025. Module 1, Development of practical skills in biology: 1.1.2 Implementing, learning outcomes (a) to (c).

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.