Skip to content
Marlbridge

Practice Questions

AQA A-Level Physics (7408): Biological measurement – Practice Questions

Original AQA A-level Physics 7408 ECG practice questions: obtaining the waveform, electrodes and amplifiers, P, QRS and T waves, and heart-rate calculations.

Subject
Physics
Level
A LEVELS
Topic
Medical physics
Updated

Aligned to AQA A Level Physics (7408), For first teaching 2015. Official specification .

Syllabus page (what it covers and how it is assessed): AQA A Level Physics.

Syllabus points this page covers

7408

  • 3.10.3 Biological measurement

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (7408).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers from your board or school.

These questions cover section 3.10.3 Biological measurement of the AQA AS and A-level Physics specification (7407/7408): simple ECG machines and the normal ECG waveform. It is part of the A-level only Medical physics option. Learn the content first in the biological measurement study guide and the biological measurement revision notes.

Resistance values for electrode contacts are illustrative values for practice.

Section A

1. State the physical quantity that an ECG records against time. [1]

2. Name the region of the heart that acts as its natural pacemaker. [1]

3. State the electrical event that produces the T wave. [1]

4. State why a conducting gel is placed between each electrode and the skin. [1]

5. A patient’s heart rate is 72 beats per minute. Calculate the distance between successive R peaks on a trace recorded at 25 mm s⁻¹. [2]

6. Explain why the patient is asked to lie still and relaxed while an ECG is recorded. [2]

Section B

7. A normal ECG waveform has three main features: the P wave, the QRS complex and the T wave.

(a) State the electrical event in the heart that produces each feature. [3]
(b) Explain why the QRS complex has the largest amplitude. [1]
(c) Explain why the trace shows no separate wave for the repolarisation of the atria. [2]

8. An ECG is recorded at a paper speed of 25 mm s⁻¹ with a vertical scale of 10 mm per mV. Successive R peaks are 18 mm apart and each R peak is 12 mm high.

(a) Calculate the heart rate in beats per minute. [2]
(b) Calculate the amplitude of the R peak in mV. [1]
(c) The amplifier output for the R peak is 1.5 V. Calculate the gain of the amplifier. [2]

9. The electrode–skin contacts have a total resistance of 40 kΩ. The heart produces a signal of 1.0 mV between the electrodes.

(a) Calculate the p.d. across the input of an amplifier of input resistance 8.0 MΩ. [2]
(b) Calculate the p.d. across the input of an amplifier of input resistance 200 kΩ. [1]
(c) The contact resistance changes slightly as the patient breathes. Explain why this matters more for the 200 kΩ amplifier. [2]

10. Describe how a good-quality ECG trace is obtained from a patient. Your answer should refer to the electrodes, the skin, the amplifier and the patient. [5]

11. Mains cables near the patient induce an interfering p.d. of the same size at every electrode. Explain how the type of amplifier used in an ECG machine reduces this interference. [2]

12. Describe the sequence of electrical events in one heartbeat, from the start of the beat to the end of the T wave, and link each event to the part of the ECG trace it produces. [4]

Answers

1. Potential difference (voltage) between electrodes on the skin [1]

2. The sinoatrial (SA) node [1]

3. Repolarisation of the ventricles [1]

4. To give a low-resistance electrical contact (no air gaps) between electrode and skin [1]

5. Period = 60/72 = 0.833 s [1]; distance = 0.833 × 25 = 20.8 mm [1]

6. Skeletal muscles produce electrical signals when they contract [1]; these would add noise to the trace and could hide or distort the heart’s signal [1]

7. (a) P wave: depolarisation of the atria [1]; QRS complex: depolarisation of the ventricles [1]; T wave: repolarisation of the ventricles [1]
(b) The ventricles contain much more muscle than the atria, so more cells depolarise together [1]
(c) Atrial repolarisation occurs at the same time as ventricular depolarisation [1]; its small signal is hidden within the much larger QRS complex [1]
Examiner insight: Name the chamber in each answer to (a); “depolarisation” alone for both P and QRS scores only once.

8. (a) T = 18/25 = 0.72 s [1]; rate = 60/0.72 = 83 beats per minute [1]
(b) 12 mm ÷ 10 mm per mV = 1.2 mV [1]
(c) Gain = 1.5/(1.2 × 10⁻³) [1]; = 1250 [1]

9. (a) V = 1.0 × 8.0/(8.0 + 0.040) [1]; = 0.995 mV [1]
(b) V = 1.0 × 200/(200 + 40) = 0.83 mV [1]
(c) With the 200 kΩ input the contact resistance is a significant fraction of the total, so a change in it changes the share of the signal reaching the amplifier noticeably [1]; the trace amplitude would vary with breathing, distorting the waveform; with 8.0 MΩ the fraction stays almost exactly 1 [1]
Examiner insight: Treat this as a potential divider; the signal p.d. splits in proportion to the resistances.

10. One mark each for any five of the following points, to a maximum of [5]: electrodes placed at standard positions on the limbs and chest so traces can be compared; skin cleaned to remove grease and dead skin (and hair removed) to lower contact resistance; conducting gel between electrode and skin for good contact; amplifier with high gain because the signal is only about 1 mV; amplifier with high input impedance so most of the signal p.d. is across the amplifier; differential amplifier to reject interference common to both electrodes; patient still and relaxed to avoid signals from skeletal muscles; output displayed against time on a screen or chart recorder.

11. The amplifier amplifies the difference between the p.d.s at two electrodes (a differential amplifier) [1]; the interference is the same at both electrodes, so it cancels in the difference while the heart’s signal, which differs between electrodes, is amplified [1]

12. The SA node starts the beat and depolarisation spreads across the atria, which contract: P wave [1]; the AV node delays the signal: flat section between P and QRS [1]; the signal is conducted rapidly through the ventricles, which depolarise and contract: QRS complex [1]; the ventricles repolarise and relax: T wave [1]

Where marks are usually lost

  • Describing the ECG as a record of heart sounds or pressure.
  • Using P to T, rather than R to R, as the period of the heartbeat.
  • Forgetting to divide by the paper speed before finding the rate.
  • Explaining high input impedance as “letting more current flow”.
  • Missing the hidden atrial repolarisation in the waveform explanation.

More on this topic

Official syllabus

AQA AS and A-level Physics specification (7407/7408), AS and A-level exams June 2016 onwards: section 3.10.3 Biological measurement (A-level only), content statement 3.10.3.1.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.