Skip to content
Marlbridge

Revision Notes

Cambridge A Level Information Technology (ICT): 16.3 Design (9626) – Revision Notes

Condensed revision notes on section 16.3 of Cambridge A Level IT 9626: DFD levels and rules, system flowchart symbols, forms, reports and a quick self-test.

Subject
ICT
Level
A LEVEL
Topic
System life cycle
Updated

Aligned to Cambridge A Level Information Technology (9626), 2025-2027. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge A Level Information Technology.

Syllabus points this page covers

9626 (A Level)

  • 16.3 Design

This page covers 1 of the 10 subtopics in topic 16, System life cycle.

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Information Technology (9626).

For full explanations and worked examples, read the section 16.3 study guide first. These notes condense section 16.3 Design of the Cambridge International AS & A Level Information Technology 9626 syllabus for examination in 2025, 2026 and 2027 (version 4). It is A Level only content, examined in Paper 3 (Advanced Theory).

Test yourself with the practice questions. The Cambridge A Level IT hub has every topic and the free diagnostics show where to start.

Design in one line

Analysis = what. Design = how. The result is the design specification.

Data flow diagrams (DFD)

Show how data moves: sources, processes, stores, destinations.

Symbol Meaning
Process Changes data; named with a verb phrase
Data store Data held between processes
Data source or destination External entity outside the system
Duplicate data source or destination Same entity drawn again to avoid crossing lines
Arrow Data flow, always labelled

Rules

  • Label every flow.
  • Data must pass through a process: no flow entity to entity, entity to store, or store to store.
  • No data stores on level 0.
  • Levels must balance: the flows into and out of the system do not change when detail is added.

Levels

Level Shows
0 (context) One process for the whole system; external entities; flows in and out
1 Main processes; data stores; flows
2 One level 1 process split into sub-processes

System flowcharts

Show the hardware, files and documents that data passes through.

Symbol Use
Input/output Data entered or received
Process Operation on data
Single document output One printed document
Multiple document output A set of printed documents
Magnetic disk file Data on disk, such as a master file
Magnetic tape file Data on tape, such as a backup
Display Output on screen

DFD vs system flowchart: a DFD shows the movement of data between processes, stores and entities (logical). A system flowchart shows the physical media and processes (hardware, files, documents).

Data storage

  • Files: input files (data waiting to be processed), output files (results), master files (permanent records), transaction files.
  • Databases: linked tables, less repeated data, many users, easy searching and reports.
  • Design records, for each table or file: fields, data types, sizes, key field, validation.

Input forms

Features and elements

  • Clear title and instructions.
  • Logical order, grouped sections.
  • Labelled fields with enough space.
  • Controls: text box, drop-down list, radio buttons (one choice), tick boxes (many choices), date picker, buttons.
  • Default values and prompts (such as DD/MM/YYYY).
  • Consistent fonts, colours, alignment; white space.
  • Paper forms: character boxes, “for office use only”.

Appropriate use: pick a control that limits mistakes (list for fixed choices, radio buttons for one-of-few, tick box for yes/no).

Validation checks data is reasonable: presence, range, type, format, length, lookup, check digit. Show a clear error message. Verification checks the data was copied correctly.

Input screen layout: first field top left, related fields grouped, logical tab order, required fields marked, buttons at the bottom.

Output reports

Output Layout points
Screen Heading, clear column titles, readable text, good colour contrast, scroll or page controls, sort and filter
Printed Title, date, page numbers, repeated column headings, header and footer, totals and sub-totals, numbers right-aligned, margins that fit the paper

Must-know distinctions

  • Level 0 (no stores) vs level 1 (stores and several processes).
  • DFD (movement of data) vs system flowchart (hardware and media).
  • Validation (reasonable) vs verification (copied correctly).
  • Radio buttons (choose one) vs tick boxes (choose any).
  • Screen output (quick, not kept) vs printed output (permanent, portable).

Quick self-test

  1. What is shown at level 0 of a DFD?
  2. Why can a data flow not go directly from an entity to a data store?
  3. Name the symbol for a printed set of payslips on a system flowchart.
  4. Name the symbol for a backup held on tape.
  5. At which DFD level do data stores first appear?
  6. Name two features of a well-designed input form.
  7. Which control should a form use to choose exactly one of three delivery options?
  8. Name two things to put on every page of a printed report.
  9. Give one example of a validation check on an input form.
  10. What is a master file?

Answers

  1. One process (the whole system), the external entities and the data flows between them.
  2. Data must pass through a process that handles it; an entity cannot update a store directly.
  3. Multiple document output.
  4. Magnetic tape file.
  5. Level 1.
  6. Any two: clear title and instructions, logical order, labelled fields, drop-down lists or radio buttons, consistent layout, defaults and prompts.
  7. Radio buttons (a drop-down list is also acceptable).
  8. Any two: page number, date, title, column headings.
  9. Any one: range check on age, presence check on surname, format check on a postcode, lookup of a title in a list.
  10. A file holding the permanent records, such as the employee file in a payroll system.

Where marks are usually lost

  • Putting data stores on a level 0 DFD.
  • Drawing flows straight from an external entity into a data store.
  • Not labelling the data flows.
  • Using the wrong symbol set (system flowchart symbols on a DFD).
  • Naming validation checks with no link to a field on the form.
  • Describing a form as “easy to use” without naming a feature.
  • Writing “colourful” for a screen layout instead of “good contrast, limited colours”.

Frequently asked questions

What are the three DFD levels in the syllabus? Level 0 (context level), level 1 and level 2. Each adds detail to the one before it while the flows into and out of the system stay the same.

Which symbols appear on a system flowchart? Input/output, process, single document output, multiple document output, magnetic disk file, magnetic tape file and display.

Why use drop-down lists on a form? They limit entries to valid choices, so they reduce errors and are quicker for the user.

Official syllabus

Cambridge International AS & A Level Information Technology 9626, syllabus for examination in 2025, 2026 and 2027, version 4, Cambridge University Press & Assessment. Section 16.3: Design.

Related resources

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.