Cambridge A Level Information Technology (ICT): 16.3 Design (9626)
Study guide to section 16.3 of Cambridge A Level IT 9626: data flow diagrams, system flowcharts, data storage, input forms and output reports.
- Subject
- ICT
- Level
- A LEVEL
- Topic
- System life cycle
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Harris Khan (what this means)
Aligned to Cambridge A Level Information Technology (9626), 2025-2027. Official specification .
Syllabus page (what it covers and how it is assessed): Cambridge A Level Information Technology.
Syllabus points this page covers
9626 (A Level)
- 16.3 Design
This page covers 1 of the 10 subtopics in topic 16, System life cycle.
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Information Technology (9626).
This guide goes deeper into section 16.3 Design of the Cambridge International AS & A Level Information Technology 9626 syllabus for examination in 2025, 2026 and 2027 (version 4). It is A Level only content examined in Paper 3 (Advanced Theory). Calculators are not allowed.
The syllabus asks you to know:
- the processing and flow of data through a system, including data flow diagrams (DFD) at level 0 (context level), level 1 and level 2, and how to construct a system flowchart and a DFD using the correct symbols
- data storage: databases and files (input and output)
- input forms: features and elements, appropriate use for data collection, validation and checking of data collected, and input screen layouts
- output reports: output screen layouts and printed copy layouts.
Use it with the whole-topic study guide, the section 16.3 revision notes and the practice questions. The Cambridge A Level IT hub lists every topic.
What the design stage does
Analysis says what the system must do. Design says how. The output is the design specification: diagrams, file and database structures, forms and reports detailed enough for developers to build from. Good design checks the idea on paper, where changes are cheap.
Data flow diagrams
A data flow diagram (DFD) shows how data moves through a system: where it comes from, what processes change it, where it is stored and where it goes. It does not show hardware or the order of decisions.
Symbols
| Element | Meaning |
|---|---|
| Process | An action that changes data, named with a verb phrase such as “Check order” |
| Data store | Where data is held between processes, such as a file or database table |
| Data source or destination | An external entity outside the system that sends data in or receives data out, such as a customer |
| Duplicate data source or destination | The same external entity drawn again to avoid crossing lines |
| Data flow (arrow) | The movement of data, labelled with what moves |
The rules
- Every data flow arrow is labelled with the data it carries.
- Data must pass through a process. A flow may not go directly between two external entities, between an entity and a data store, or between two data stores.
- Every process has at least one input and one output.
- Each data store needs data going in and coming out of it (or the store is pointless).
- Level 0 shows no data stores.
Levels
| Level | What it shows |
|---|---|
| Level 0 (context diagram) | The whole system as one process, with all external entities and the data flows between them and the system |
| Level 1 | The one process broken into the main processes, with data stores and the flows between them |
| Level 2 | One level 1 process broken down further into its sub-processes |
Each level must be consistent with the one above: the data flowing in and out of the system at level 1 must match level 0. Detail is added, not changed.
Worked example: school trip payments
External entities: Parent and Teacher.
Level 0. One process, “School trip payment system”.
- Parent to system: Payment, Consent form
- System to Parent: Receipt
- Teacher to system: Trip details
- System to Teacher: List of paid pupils
Level 1. The process is broken into:
- Process 1 “Record trip”: receives Trip details from Teacher and writes Trip record to the data store Trips.
- Process 2 “Take payment”: receives Payment and Consent form from Parent, reads Trip cost from Trips, writes Payment record to Payments and sends Receipt to Parent.
- Process 3 “Produce list”: reads Payment record from Payments and Trip record from Trips, and sends List of paid pupils to Teacher.
Check: the same five external flows appear at level 0 and level 1 (Trip details, Payment, Consent form, Receipt, List of paid pupils). The two data stores appear only at level 1.
Level 2 for process 2 might show “Check payment amount”, “Record consent” and “Print receipt”, with sub-processes numbered 2.1, 2.2 and 2.3.
System flowcharts
A system flowchart shows the hardware and files that data passes through and the processes applied to it. It is more physical than a DFD: it shows the media (disk, paper, screen) involved. Symbols from the syllabus are:
| Element | Use |
|---|---|
| Input/output | Data entered or received |
| Process | An operation carried out on the data |
| Single document output | One printed document |
| Multiple document output | Several copies or documents, such as a set of payslips |
| Magnetic disk file | Data held on disk, such as a master file |
| Magnetic tape file | Data held on tape, such as a backup |
| Display | Output on a screen |
Flow lines with arrowheads join the symbols.
Worked example: weekly payroll
- Timesheets are keyed in (input).
- “Validate timesheet data” (process), with errors sent to the display.
- Valid data is written to the transaction file on magnetic disk.
- “Calculate pay” (process) reads the transaction file and the employee master file (magnetic disk).
- The master file is updated (written back to disk).
- Payslips are produced (multiple document output).
- A copy of the master file is written to magnetic tape as a backup.
Data storage
Designers decide how data will be stored.
- Files hold data in a structured way. Input files hold data waiting to be processed, such as transactions, and output files hold results. A master file holds permanent records.
- Databases hold related tables with linked keys. They avoid repeated data, allow several users and make searching and reports easier.
The design specifies each table or file: the fields, the data type and size of each field, the key field and the validation rules.
Input forms
An input form collects data, on paper or on screen.
Features and elements
- A clear title and short instructions.
- Fields in a logical order that follows the source document, grouped in sections.
- Each field has a clear label and enough space for the longest value.
- Suitable controls: text boxes, drop-down lists and radio buttons (choose one), tick boxes (choose any), date pickers, buttons such as Submit and Clear.
- Default values and prompts, for example a date format guide such as DD/MM/YYYY.
- Consistent fonts, colours and alignment, with enough white space to be easy to read.
- On paper forms, character boxes (one box per letter) and a section marked “For office use only”.
Appropriate use
Choose the control that limits wrong entries: a drop-down list for a title or a county; radio buttons for male/female/other; a tick box for “I agree”.
Validation and checking
Validation checks that data is reasonable, not that it is correct. Typical checks: presence, range, type, format, length, lookup (list) and check digit. A form should show a clear error message that says what is wrong and how to fix it. Verification (for example double entry or visual checking) confirms that data was copied correctly.
Input screen layouts
A screen layout shows where each label, field and button goes. Good practice: place the first field top left, group related fields, keep the tab order logical, mark required fields and put buttons at the bottom.
Output reports
Output screen layouts
On screen, a report should have a heading, clear column titles, readable text size, limited colours with good contrast, scroll or page controls, and options to sort or filter. Screens suit data needed quickly and not kept.
Printed copy layouts
Printed reports need a title, the date and time, page numbers, column headings repeated on every page, headers and footers, totals and sub-totals, consistent alignment (numbers right-aligned), margins that fit the paper and no cut-off columns. Printed reports suit records, legal documents and people without a screen.
Common errors
- Drawing a data flow between an external entity and a data store.
- Showing data stores on a level 0 diagram.
- Leaving data flows unlabelled.
- Using the system flowchart symbols when asked for DFD symbols.
- Listing validation checks without saying what they check on the form.
- Describing “good design” without naming a feature, such as drop-down lists or instructions.
Frequently asked questions
What does a level 0 DFD show? It shows the whole system as one process, the external entities and the data flowing between them and the system. It shows no data stores.
What is the difference between a DFD and a system flowchart? A DFD shows how data moves between processes, stores and external entities. A system flowchart shows the hardware, files and documents that the data passes through.
What is validation on an input form? Validation is an automatic check that entered data is reasonable, such as a date in a valid range, and does not prove that it is correct.
Official syllabus
Cambridge International AS & A Level Information Technology 9626, syllabus for examination in 2025, 2026 and 2027, version 4, Cambridge University Press & Assessment. Section 16.3: Design.
Related resources
-
Practice questions
Cambridge A Level Information Technology (ICT): 16.3 Design (9626) – Practice Questions
Original practice questions with marked answers on DFDs, system flowcharts, input forms and output reports for section 16.3 of Cambridge A Level IT 9626.
ICT · Cambridge · A Level
Try questions -
Revision notes
Cambridge A Level Information Technology (ICT): 16.3 Design (9626) – Revision Notes
Condensed revision notes on section 16.3 of Cambridge A Level IT 9626: DFD levels and rules, system flowchart symbols, forms, reports and a quick self-test.
ICT · Cambridge · A Level
Revise topic -
Study guides
Cambridge A Level Information Technology (ICT): 16.4 Development and testing (9626)
Study guide to section 16.4 of Cambridge A Level IT 9626: test plans, test data, alpha and beta testing, white box and black box testing, with a worked test plan.
ICT · Cambridge · A Level
Read guide
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.