Cambridge O Level Physics (5054): Practical electricity – Practice Questions

Original 5054 questions with full answers on electrical power and energy, kW h and cost, parallel lighting, fuse ratings, trip switches, earthing and wiring.

Subject
Physics
Level
O LEVELS
Topic
Electricity and magnetism
Updated

Aligned to Cambridge O Level Physics (5054), 2026-2028. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge O Level Physics.

Syllabus points this page covers

5054

  • 4.4 Practical electricity

Found an error? Report a correction.

Need help with this topic? Request a free trial class for O Level Physics (5054).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs — Cambridge International holds copyright in its own papers. Use these alongside the official past papers available from your board.

Related: Practical electricity study guide and Practical electricity revision notes

All prices in these questions are invented for practice.


Section A

1. State two common uses of electricity in the home. [2]

2. Define the kilowatt-hour and state its value in joules. [2]

3. A hair dryer has a power of 1.2 kW and runs on a 230 V supply. Calculate the current it takes. [2]

4. An appliance takes 4.0 A from a 230 V supply for 2.0 minutes. Calculate the energy transferred. [2]

5. State the danger of (a) damaged insulation on a mains cable, and (b) plugging too many appliances into one extension lead. [2]

6. Name the three wires in a mains circuit, and state which one carries a current only when there is a fault. [2]

Section B

7. The lights in a house are connected in parallel on a 230 V circuit.

(a) State three advantages of connecting the lamps in parallel rather than in series. [3]
(b) Eight 60 W lamps are switched on together. Calculate the total power and the current from the supply. [2]
(c) Trip switches with settings of 3 A and 5 A are available. State which is more suitable for this circuit. [1]

8. In one day a family uses a 2.2 kW washing machine for 1.5 hours, a 3.0 kW oven for 40 minutes and a 120 W television for 5.0 hours. Electricity costs $0.18 per kW h.

(a) Calculate the energy, in kW h, used by each appliance. [3]
(b) Calculate the total energy used and the total cost. [2]

9. Fuses rated at 3 A, 5 A and 13 A are available. The supply is 230 V.

(a) Choose a fuse for an 800 W microwave oven, showing your working. [2]
(b) Choose a fuse for a 2.9 kW kettle, showing your working. [2]
(c) Explain why fitting a 13 A fuse to the microwave oven would be unsafe. [2]

10. A washing machine has a metal case connected to the earth wire. A fault causes the live wire to touch the case. Explain how the earth wire and the fuse together prevent an electric shock. [4]

11. A hair dryer has a plastic case and is connected with only live and neutral wires. Explain why it does not need an earth wire. [2]

12. An electrician wrongly connects a light switch into the neutral wire instead of the live wire. The light still turns on and off. Explain why this wiring is dangerous. [3]

13. (a) Describe how a fuse protects a circuit. [2] (b) Give two advantages of a trip switch (circuit breaker) over a fuse. [2]

14. Explain why overloading an extension lead with several high-power appliances is a fire hazard. [3]


Answers

1. Any two, 1 mark each: heating (kettle, heater); lighting; charging batteries; powering motors (fan, washing machine); powering electronic systems (computer, television).

2. The energy transferred by a 1 kW appliance in 1 hour [1]; 1 kW h = 3.6 × 10⁶ J [1].

3. I = P ÷ V = 1200 ÷ 230 [1] = 5.2 A [1].

4. E = I V t = 4.0 × 230 × 120 [1] = 110 000 J (1.1 × 10⁵ J) [1].

5. (a) Exposed live wire can give an electric shock (or cause a short circuit and fire) [1].
(b) Excess current makes the cables overheat, which can cause a fire [1].

6. Live, neutral and earth [1]; the earth wire carries current only in a fault [1].

7. (a) Each lamp has the full supply p.d. and works at normal brightness [1]; each lamp can be switched on and off independently [1]; if one lamp fails the others stay on [1].
(b) P = 8 × 60 = 480 W [1]; I = 480 ÷ 230 = 2.1 A [1].
(c) 3 A — the smallest setting above the working current [1].

8. (a) Washing machine: 2.2 × 1.5 = 3.3 kW h [1]. Oven: 3.0 × (40 ÷ 60) = 2.0 kW h [1]. Television: 0.12 × 5.0 = 0.60 kW h [1].
(b) Total = 3.3 + 2.0 + 0.60 = 5.9 kW h [1]; cost = 5.9 × 0.18 = $1.06 [1].

9. (a) I = 800 ÷ 230 = 3.5 A [1]; choose the 5 A fuse [1].
(b) I = 2900 ÷ 230 = 12.6 A [1]; choose the 13 A fuse [1].
(c) A fault current well above the normal 3.5 A, but below 13 A, would not melt the fuse [1], so the cable or appliance could overheat and catch fire [1].

10. The live wire touching the case gives a low-resistance path from live through the case to earth [1], so a very large current flows [1]. This melts the fuse (in the live wire) [1], disconnecting the appliance from the live supply, so the case does not stay live and anyone touching it is safe [1].

11. The case is non-conducting (double-insulated) [1], so even if a live wire came loose inside, the outer case could not become live [1].

12. With the switch in the neutral wire, turning it off stops the current but leaves the lamp connected to the live wire [1]. The lamp fitting therefore stays at a high p.d. even when the light is off [1], so someone changing the bulb or touching the fitting could get an electric shock [1].

13. (a) The fuse wire heats up and melts if the current exceeds its rating [1], breaking the circuit and stopping the current before cables overheat [1].
(b) It can be reset once the fault is cleared, instead of being replaced [1]; it acts faster when the current becomes too large [1].

14. Each appliance draws current through the lead, so the total current is very large [1]. A large current heats the cable and connections [1]; the insulation can melt and the heat can start a fire [1].


Where marks are usually lost

  • Mixing units: kW with minutes, or W with hours, in energy and cost calculations.
  • Choosing a fuse equal to or below the working current, or far above it.
  • Explaining earthing without stating that the large current melts the fuse or trips the breaker.
  • Saying the earth wire carries current all the time.
  • Giving “so the light works” as the reason for a switch in the live wire, instead of disconnecting the appliance from the high p.d.
  • Saying parallel lamps share the supply p.d.; each has the full p.d.