Skip to content
Marlbridge

Revision Notes

Cambridge O Level Physics (5054): Practical electricity – Revision Notes

Quick recall for 5054 subtopic 4.4: P = IV, E = IVt, kW h and cost, lamps in parallel, hazards, fuses, trip switches, earthing and live-wire switching.

Subject
Physics
Level
O LEVELS
Topic
Electricity and magnetism
Updated

Aligned to Cambridge O Level Physics (5054), 2026-2028. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge O Level Physics.

Syllabus points this page covers

5054

  • 4.4 Practical electricity

Found an error? Report a correction.

Need help with this topic? Request a free trial class for O Level Physics (5054).

Condensed notes for subtopic 4.4 Practical electricity in Cambridge O Level Physics 5054. For full explanations and worked examples, use the Practical electricity study guide; for exam-style questions, use the Practical electricity practice questions.

Equations

P = I V                         W = A × V
E = I V t                       J = A × V × s
energy (kW h) = P (kW) × t (h)
1 kW h = 3.6 × 10⁶ J
cost = number of kW h × price per kW h

Unit pairs: W with s gives J; kW with h gives kW h.

Uses of electricity

Heating · lighting · battery charging · powering motors · powering electronic systems.

Lamps in parallel — advantages

  1. Each lamp has the full supply p.d. → normal brightness.
  2. Each can be switched independently.
  3. One failing does not switch off the others.

Hazards

Hazard Danger
Damaged insulation Shock from exposed live wire; short circuit and fire
Overheating cables Insulation melts; fire
Damp conditions Water conducts; shock
Overloaded plugs, extension leads, sockets Excess current overheats cables; fire

Fuses and trip switches

Feature Fuse Trip switch (circuit breaker)
How it works Thin wire heats and melts when current exceeds rating Switch opens automatically when current exceeds setting
After a fault Must be replaced Can be reset
Speed Slower Faster
Placed in Live wire Live wire

Choosing a rating: I = P ÷ V, then the smallest available rating above that current.

Example: 1150 W on 230 V → 5.0 A → a 5 A fuse would be at its limit, so choose the next rating up (for example 13 A if only 3 A, 5 A and 13 A are available). A fuse should not run at exactly its rated current.

The three wires

Wire Role
Live (line) Carries the high alternating p.d.
Neutral Completes the circuit; close to 0 V
Earth Safety wire to the metal case; carries current only in a fault

Earthing — the chain of events

Live wire touches earthed metal case → very low resistance path to earth → very large current → fuse melts or breaker trips → appliance disconnected from live → case not live, no shock.

Double insulation: non-conducting outer case cannot become live, so no earth wire is needed.

Switch and fuse in the live wire

  • Switch off → appliance disconnected from the high p.d.
  • Switch in the neutral → appliance still connected to live when “off”: shock risk during repair.
  • Fuses and breakers in live so that, when they act, the appliance is isolated from live.

Key terms

Term Meaning
Kilowatt-hour Energy transferred by a 1 kW appliance in 1 hour (3.6 × 10⁶ J)
Power Energy transferred per second; P = I V
Fuse A thin wire in the live wire that melts if the current exceeds its rating
Trip switch An automatic switch that opens when the current exceeds its setting; resettable
Earth wire Low-resistance safety connection from a metal case to the ground
Double insulation A non-conducting casing so that the outside cannot become live
Overloading Drawing too much current through one socket, plug or extension lead

Exam traps

  • Minutes must become hours for kW h, and seconds for joules.
  • Do not pick a fuse with a rating equal to or below the working current.
  • Do not pick a much larger fuse “for safety” — it would not blow in a fault.
  • The earth wire does not carry current in normal use.
  • Explaining earthing without saying the fuse melts or breaker trips loses the key mark.
  • Switch in the live wire: the reason is that the appliance is disconnected from the high p.d., not “so it works”.
  • In a parallel lighting circuit, every lamp gets the full p.d.

Self-test

  1. State three common uses of electricity.
  2. Give two advantages of connecting house lamps in parallel.
  3. Find the power of a device taking 0.26 A from 230 V.
  4. Find the energy transferred by a 12 V, 2.0 A motor in 5.0 minutes.
  5. Define the kilowatt-hour.
  6. A 60 W lamp is left on for a week (168 h). Find the energy in kW h.
  7. At an invented price of $0.15 per kW h, find the cost in question 6.
  8. Calculate the current in a 2.5 kW heater on 230 V and choose a fuse from 3 A, 5 A and 13 A.
  9. State one hazard of damp conditions when using mains appliances.
  10. Explain why a metal-cased appliance is earthed.
  11. Why does a double-insulated appliance not need an earth wire?
  12. Why must the switch be in the live wire?

Answers

  1. Any three: heating, lighting, battery charging, powering motors, powering electronic systems.
  2. Each gets the full p.d. (full brightness); each switched independently; one failing leaves the others on (any two).
  3. P = 0.26 × 230 = 60 W (59.8 W).
  4. E = 2.0 × 12 × 300 = 7200 J.
  5. The energy transferred by a 1 kW appliance in 1 hour.
  6. 0.060 × 168 = 10 kW h (10.08).
  7. 10.08 × 0.15 = $1.51.
  8. I = 2500 ÷ 230 = 10.9 A, so 13 A (the smallest rating above the working current).
  9. Water conducts, so current can flow through a person: electric shock.
  10. If the live wire touches the case, a large current flows to earth, melting the fuse or tripping the breaker so the case cannot stay live.
  11. Its casing is non-conducting, so it cannot become live.
  12. So that when switched off the appliance is disconnected from the high p.d. of the live wire.

Written against Cambridge O Level Physics 5054, 2026–2028 series.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.