Skip to content
Marlbridge

Practice Questions

Edexcel International A Level Physics (YPH11): Unit 6 Implementation and Measurements – Practice Questions

Twelve original questions on judging partial experiment details, units, rounding and anomalies, with answers, for Edexcel IAL Physics Unit 6 section 6.4.

Subject
Physics
Level
A LEVELS
Topic
Unit 6: Practical Skills in Physics II
Updated

Aligned to Pearson Edexcel A Level Physics (YPH11), Issue 3. Official specification .

Syllabus page (what it covers and how it is assessed): Pearson Edexcel A Level Physics.

Syllabus points this page covers

YPH11

  • 6.4 Implementation and Measurements

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (YPH11).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers available free from your board.

Related: Unit 6 implementation and measurements study guide | Unit 6 implementation and measurements revision notes

These questions cover section 6.4 Implementation and Measurements of Unit 6: Practical Skills in Physics II, Pearson Edexcel IAL Physics (YPH11), Issue 3. Each question gives partial details of how an experiment was carried out.

Section A

1. Amend each column heading: (i) T² / s; (ii) lg I / W m⁻²; (iii) 1/V / cm³; (iv) Q / C⁻¹. [4]

2. A digital thermometer reads to 0.1 °C. A student records 23.47 °C, 40 °C and 48.66 °C. Write each to the correct number of figures. [3]

3. Explain how a marker improves the timing of oscillations of a pendulum. [2]

4. A student times 5 oscillations of a spring of period about 0.60 s. Reaction-time uncertainty is 0.2 s. Calculate the percentage uncertainty in the time, and the percentage uncertainty if 30 oscillations were timed instead. [3]

5. To investigate the force on a current-carrying wire in a magnetic field, a student measures the force at currents of 0.5 A, 1.0 A and 1.5 A. The supply can give up to 5.0 A safely. Comment on the number and range of readings. [3]

6. A student records counts from a radioactive source but describes no measurement without the source. Explain why this is a weakness. [2]

Section B

7. A 1.00 kg aluminium block is heated by a 36 W heater. A student records its temperature every minute.

t / s 0 1 2 3 4 5
θ / °C 20.0 22.4 24.80 28.5 29.6 32

(a) Identify and amend the incorrect unit. [1]
(b) Identify and correct two entries with incorrect significant figures, assuming the thermometer reads to 0.1 °C. [2]
(c) Identify the inconsistent reading and state the value expected. [2]
(d) Use the consistent readings to calculate the specific heat capacity of aluminium, ignoring energy losses. [3]
(e) Suggest two improvements, using additional apparatus, and explain each. [4]

8. To find the volume of a large can, a student holds a 30 cm ruler across the end of the can, reads the diameter once as 7.4 cm, and measures the height with the same ruler.

(a) Describe how set squares should be used to measure the diameter. [3]
(b) Comment on the way the diameter is recorded. [1]
(c) Explain why the diameter should be measured at more than one orientation. [1]

9. A student records the counts in 10 s from a decaying source every 30 s. The background is 5 counts in 10 s.

t / s 0 30 60 90 120 150
Counts in 10 s 405 325 261 238 169 136

(a) Correct the counts for background and show which reading is inconsistent. [3]
(b) Explain why the background correction matters more at later times. [2]
(c) The half-life is about 93 s. Comment on the range of times used. [2]
(d) Suggest how the random nature of decay should be allowed for. [2]

10. A student measures how the period of a mass on a spring depends on the mass. She uses masses of 0.10 kg, 0.15 kg and 0.20 kg, and times 5 oscillations once for each, starting the stopwatch when the mass is at the top of its motion. Comment on her method and suggest improvements. [6]

11. In a collision experiment a card on a glider passes through a light gate. The student measured the card’s length with a 30 cm ruler as 5 cm. His table includes the headings “velocity / m s” and “momentum / kg m s⁻²”.

(a) Amend both headings. [2]
(b) Comment on the card measurement and suggest an improvement. [3]

12. A student pushes the plunger of a sealed syringe quickly to each new volume and reads a pressure gauge at once.

V / cm³ 50 40 30 25 20
p / kPa 100 125 175 200 250

(a) Use pV to identify the inconsistent reading and state the value expected. [2]
(b) Explain how pushing quickly and reading at once could affect the readings. [2]
(c) Suggest an improvement to the method. [2]

Answers

1. (i) T² / s² [1]. (ii) lg (I / W m⁻²) [1]. (iii) V⁻¹ / cm⁻³ [1]. (iv) Q / C [1]. [4]

2. 23.5 °C [1]; 40.0 °C [1]; 48.7 °C [1]. [3]

3. A fixed marker at the equilibrium position gives a definite point to start and stop the timer [1]; the bob passes it at its highest speed, so the moment is sharper than judging the turning point [1]. [2]

4. 5 oscillations: 0.2 ÷ 3.0 × 100% = 6.7% [1]. 30 oscillations: total about 18 s [1], so 0.2 ÷ 18 × 100% = 1.1% [1]. [3]

5. Three readings are too few to establish a proportional relationship [1]. The range uses only up to 1.5 A of the 5.0 A available [1], so take at least six readings from about 0.5 A to 5.0 A [1]. [3]

6. Without a background count rate, counts from other sources are included in every reading [1], so the count rate from the source is overestimated, a systematic error, especially when the count is low [1]. [2]

7. (a) The times are in minutes, so the heading should be t / min (or convert the values to seconds) [1].
(b) 24.80 should be 24.8 [1]; 32 should be 32.0 [1].
(c) 28.5 °C at 3 min [1]: the temperature rises 2.4 °C each minute, so 27.2 °C is expected [1].
(d) Rate of rise = 2.4 °C per minute = 2.4 ÷ 60 = 0.0400 K s⁻¹ [1]. P = mc(Δθ/Δt), so c = 36 ÷ (1.00 × 0.0400) [1] = 900 J kg⁻¹ K⁻¹ [1].
(e) Wrap the block in insulation [1], reducing energy lost to the surroundings, which would make c too large [1]. Put a few drops of oil in the thermometer hole [1], improving thermal contact so the thermometer reads the block’s true temperature [1]. [12]
Examiner insight: A joulemeter measuring the energy supplied directly is also a creditworthy improvement.

8. (a) Lay the can on its side against a metre rule fixed to the bench [1]. Place a set square on each side with its vertical edge just touching the can [1], and read the rule at each set square; the diameter is the difference between the readings [1].
(b) 7.4 cm is given to 1 mm, which a ruler can read, but a single reading taken across a curved end may be a chord, not the diameter, and should be written in mm as, for example, 74 mm with its uncertainty [1].
(c) The can may not be perfectly circular, so readings at several orientations give a mean diameter [1]. [5]

9. (a) Corrected counts: 400, 320, 256, 233, 164, 131 [1]. Each step should multiply by 0.80; 256 × 0.80 = 205 is expected at 90 s [1], so 238 (233 corrected) is inconsistent [1].
(b) The source’s count falls with time while the background stays the same [1], so the background becomes a larger fraction of each reading [1].
(c) 150 s is only about 1.6 half-lives [1]; continue to about 300 s, three or more half-lives, to test the exponential decay fully [1].
(d) Count for longer than 10 s at each time, or repeat [1], because random variation is a smaller fraction of a larger count [1]. [9]

10. Three masses are too few, and 0.10–0.20 kg is a narrow range [1]: use at least six masses over a wider range, for example 0.10–0.60 kg [1]. Timing 5 oscillations gives a large reaction-time uncertainty [1]: time 20 oscillations and divide [1]. Starting at the top of the motion, where the mass is momentarily still, makes the instant uncertain [1]: use a fiducial marker at the equilibrium position and repeat each timing three times [1]. [6]

11. (a) velocity / m s⁻¹ [1]; momentum / kg m s⁻¹ [1].
(b) “5 cm” is recorded to the nearest centimetre, although a ruler reads to 1 mm [1]; the card length goes straight into the velocity, so a large uncertainty here spoils every result [1]. Measure it with Vernier calipers, for example 50.0 mm, at both edges [1]. [5]

12. (a) pV is 5000 kPa cm³ for every reading except 30 cm³, which gives 5250 [1]; expected p = 5000 ÷ 30 = 167 kPa [1].
(b) Rapid compression warms the air [1], so the pressure read at once is higher than at constant temperature [1].
(c) Move the plunger slowly and wait about a minute after each change [1], so the air returns to room temperature before p is read [1]. [6]

Where marks are usually lost

  • Putting a unit on a logarithm, or forgetting to square or invert a unit.
  • Commenting on significant figures without writing the corrected value.
  • Identifying an inconsistent reading with no expected value.
  • Forgetting that background counts must be subtracted as rates before any pattern is checked.
  • Giving improvements with no error named.

Official syllabus

Pearson Edexcel International Advanced Subsidiary/Advanced Level in Physics, Issue 3, Unit 6, section 6.4 Implementation and Measurements.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.