Skip to content
Marlbridge

Revision Notes

Edexcel International A Level Physics (YPH11): Unit 6 Implementation and Measurements – Revision Notes

Recall notes for Edexcel IAL Physics Unit 6 section 6.4: improvements, readings, range, rounding tables, amending units and anomalies, with a self-test.

Subject
Physics
Level
A LEVELS
Topic
Unit 6: Practical Skills in Physics II
Updated

Aligned to Pearson Edexcel A Level Physics (YPH11), Issue 3. Official specification .

Syllabus page (what it covers and how it is assessed): Pearson Edexcel A Level Physics.

Syllabus points this page covers

YPH11

  • 6.4 Implementation and Measurements

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (YPH11).

Condensed notes for section 6.4 Implementation and Measurements, Unit 6: Practical Skills in Physics II, Pearson Edexcel IAL Physics (YPH11), Issue 3. A full worked critique is in the Unit 6 implementation and measurements study guide; questions are in the Unit 6 implementation and measurements practice questions.

What you are given and what you do

You get partial details of how an experiment was carried out, sometimes with results. You:

  1. Suggest improvements, possibly with additional apparatus, saying which error each reduces.
  2. Comment on the number of readings.
  3. Comment on the range.
  4. Identify and/or round incorrect figures in a table.
  5. Identify and/or amend incorrect units.
  6. Identify and check an inconsistent reading.

New compared with Unit 3: amending units and rounding figures yourself.

Units: the rules

Rule Wrong Right
Column headings are quantity / unit t (s), Time in seconds t / s
Values match the heading’s unit V / mV with values 6.00, 4.90 V / V
A log has no unit ln V / V ln (V / V)
Squared quantities square the unit T² / s T² / s²
Reciprocals invert the unit 1/V / m³ V⁻¹ / m⁻³
Derived units correct ρ / Ω m⁻¹ ρ / Ω m
Time constant is a time RC = 50 s⁻¹ RC = 50 s
Gradient unit = y unit ÷ x unit gradient of ln V against t in s gradient in s⁻¹

Significant figures: rounding a table

  • Raw readings: same number of decimal places as the instrument’s resolution, throughout the column.
  • An entry with too many figures (2.696 V from a meter reading to 0.01 V) is rounded: 2.70 V.
  • An entry with too few figures (4.9 V) should show the instrument’s resolution: 4.90 V if that was the reading.
  • Processed values: usually 3 significant figures; a mix of 3 and 4 is accepted across a power of ten.
  • Averages: no more decimal places than the readings averaged.

Checking an inconsistent reading

  1. Choose the test the physics suggests: constant ratio, constant difference, constant difference of logs, straight line.
  2. Calculate it for every row.
  3. Name the odd row and calculate the expected value.
  4. Suggest a cause (timing delay, misread scale, wrong range, a variable changed).
  5. Check it: repeat that reading, or repeat the run; exclude only with a reason.

Worked reminder: an exponential decay falls by the same fraction in equal times, so ln y falls by the same amount. Counts of 800, 640, 470, 410, 328 every 30 s: ratios 0.80, 0.73, 0.87, 0.80. The 470 is odd; expected 640 × 0.80 = 512.

Improvements bank (Units 4 and 5 contexts)

Weakness Improvement Error reduced
Diameter of a large cylinder judged with a rule held across it Set squares either side against a fixed rule; repeat at different orientations Parallax; measuring a chord, not the diameter
Oscillations timed from the turning point Fiducial marker at the equilibrium position Uncertain start and stop instant
Few oscillations timed Time 20 and divide Reaction time as a fraction of total
Stopwatch and meter read by two people Data logger Delay between calling time and reading
Short time constant timed by hand Larger R, or data logger Timing uncertainty
No background count Measure background over at least 10 minutes and subtract the rate Systematic overestimate of count rate
Gas readings taken immediately after compression Wait for temperature to settle Temperature change during readings
Heating with no lid or insulation Insulate the beaker or block, use a lid Energy lost to surroundings
Collision speeds from a stopwatch Light gates or video analysis with a scale Reaction time; timing short intervals

Number and range

  • At least 6 values of the independent variable; more for curves.
  • For a decay or discharge, cover at least two to three time constants or half-lives.
  • For oscillations, cover a wide range of masses or lengths (for example a factor of five).
  • “More readings” and “wider range” are different comments: say which is needed.

Key terms

Term Meaning
Partial details A description of an experiment with steps or data left out
Fiducial marker A fixed point used to start and stop timing
Data logger A device recording readings automatically at set intervals
Inconsistent reading One that does not fit the pattern of the others
Time constant RC, the time for V to fall to 1/e of its starting value
Half-life Time for the activity (or count rate) to halve
Background count rate Count rate with the source removed
Resolution Smallest interval an instrument can show

Exam traps

  • Writing a unit after a log column heading.
  • Quoting RC or T² with the wrong unit.
  • Saying a value has the “wrong significant figures” without writing the corrected value.
  • Calling a point anomalous because it “looks off” with no calculation.
  • Suggesting set squares or a marker without saying how they are used.
  • Ignoring a missing background correction in a radioactivity table.

Self-test

1. Correct the heading “ln T / s”. 2. A meter reads to 0.01 A. Round 0.4672 A for the table. 3. A column labelled “1/p / Pa” should read what? 4. State the unit of the gradient of a graph of ln V against t. 5. Counts every 20 s: 900, 720, 576, 520, 369. Which is inconsistent? 6. Using Question 5, what value is expected? 7. How do set squares help measure a cylinder’s diameter? 8. Why is a fiducial marker placed at the equilibrium position? 9. Timing 10 oscillations of 1.2 s with 0.2 s reaction uncertainty gives what percentage uncertainty? 10. A discharge is followed for one time constant only. Comment. 11. Two students read a stopwatch and a meter together. Suggest an improvement. 12. A table gives T² in s. Amend it.

Answers

1. ln (T / s). 2. 0.47 A. 3. p⁻¹ / Pa⁻¹. 4. s⁻¹. 5. 520: the first two ratios are 0.80, but 520 ÷ 576 = 0.90 and 369 ÷ 520 = 0.71. 6. 576 × 0.80 = 461 (to 3 s.f.). 7. Their vertical edges touch the widest points and transfer them to the rule at right angles, avoiding parallax. 8. The object moves fastest there, so the instant it passes is sharpest. 9. 0.2 ÷ 12 × 100% = 1.7%. 10. The range is too small to test the exponential; continue to about three time constants. 11. Use a data logger to record p.d. against time automatically. 12. T² / s².

Official syllabus

Pearson Edexcel International Advanced Subsidiary/Advanced Level in Physics, Issue 3, Unit 6, section 6.4 Implementation and Measurements.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.