Skip to content
Marlbridge

Practice Questions

Edexcel International A Level Physics (YPH11): Unit 3 Planning – Practice Questions

Twelve original Unit 3 planning questions with mark-scheme answers: instrument choice, errors, controls, full plans, safety and context, Edexcel IAL Physics.

Subject
Physics
Level
A LEVELS
Topic
Unit 3: Practical Skills in Physics I
Updated

Aligned to Pearson Edexcel A Level Physics (YPH11), Issue 3. Official specification .

Syllabus page (what it covers and how it is assessed): Pearson Edexcel A Level Physics.

Syllabus points this page covers

YPH11

  • 3.3 Planning

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (YPH11).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers available free from your board.

Related: Unit 3 planning study guide | Unit 3 planning revision notes

These questions cover section 3.3 Planning of Unit 3: Practical Skills in Physics I, Pearson Edexcel IAL Physics (YPH11), Issue 3. Take g = 9.81 m s⁻².

Section A

1. State the resolution of Vernier calipers and of a micrometer screw gauge, and the uncertainty in a single reading from each. [2]

2. A student plans to measure the thickness of a sheet of card, about 0.8 mm, with a metre rule. Calculate the percentage uncertainty, then name a better instrument and calculate the percentage uncertainty it would give. [3]

3. Explain the difference between a systematic error and a random error, and give one way of reducing each. [4]

4. A student plans to find the stiffness k of a spring by adding masses and measuring the extension. Identify the independent variable, the dependent variable and one control variable. [3]

5. Discuss whether repeat readings are appropriate when (i) timing a ball falling through a tall tube of oil with a stopwatch, and (ii) reading the length of a wire that the student has set to 0.500 m with a metre rule. [3]

6. Describe how a student should check a digital voltmeter before using it. [2]

Section B

7. Plan an experiment to determine the speed of sound in air using a signal generator, a loudspeaker, a microphone and a 2-beam oscilloscope. Your plan should include the measurements, how you would make them precise, how the data would be used and one safety point. [8]

8. Plan an experiment to investigate how the current in a filament lamp varies with the potential difference across it, from 0 V to 12 V. Include the circuit, the instruments with suitable ranges, the method, one safety precaution and how the results would be presented. [8]

9. A student plans to determine the wavelength of light from a laser using a diffraction grating and a screen 1.5 m away.

(a) Identify two sources of uncertainty and explain how each may be reduced. [4]
(b) Identify one hazard and a precaution. [2]
(c) Comment on one use of diffraction gratings and its context. [2]

10. A student plans to find the density of copper from a rod about 8 mm in diameter and 500 mm long, with a mass of about 225 g.

(a) Choose an instrument for each of the diameter, the length and the mass, and calculate the percentage uncertainty in a single reading for the diameter and the length. [5]
(b) State one calibration check the student should make. [1]

11. A student writes this plan to find the e.m.f. and internal resistance of a cell. “Connect the cell to a variable resistor, an analogue ammeter and an analogue voltmeter. Set the resistor to three values and record I and V with the switch closed throughout. Calculate r from one pair of readings.” The voltmeter reads 0.05 V when disconnected. Identify four weaknesses and suggest an improvement for each. [8]

12. A student will hang masses on a long copper wire and measure its extension, to find the Young modulus. Describe how the data collected will be used to find the Young modulus. [4]

Answers

1. Vernier 0.1 mm, uncertainty 0.05 mm [1]; micrometer 0.01 mm, uncertainty 0.005 mm [1]. [2]

2. Metre rule: 0.5 ÷ 0.8 × 100% = 63% [1]. A micrometer screw gauge [1]: 0.005 ÷ 0.8 × 100% = 0.63% [1]. [3] Examiner insight: A good alternative is to measure a stack of 20 sheets with a micrometer or Vernier and divide by 20.

3. A systematic error shifts every reading by the same amount or in the same direction [1], such as a zero error; it is reduced by calibrating or correcting the instrument [1]. A random error causes unpredictable scatter about the true value [1]; it is reduced by repeating readings and taking a mean, or by plotting a graph [1]. [4]

4. Independent: the load (mass or weight) added [1]. Dependent: the extension [1]. Control: the same spring throughout, or the same temperature [1]. [3]

5. (i) Yes: the start and stop depend on the student’s reaction and judgement, so random scatter is likely [1]; take at least three and use the mean [1]. (ii) No: the length is set by the student, so repeating the same rule reading adds nothing [1]. [3]

6. With the leads connected together, or not connected to anything, check it reads zero [1]; if not, note the offset and subtract it from every reading [1]. [2]

7. Connect the signal generator to the loudspeaker and to one channel of the oscilloscope; the microphone goes to the other channel [1]. Set a frequency, for example 2.0 kHz, and read f from the generator, checked against the period on the oscilloscope [1]. Move the microphone along a metre rule fixed on the bench until the two traces are in phase, and note the position [1]. Move it further, counting several more in-phase positions, for example five, and measure the total distance [1]; dividing by the number of wavelengths reduces the percentage uncertainty in λ [1]. Repeat for at least five frequencies [1]. Plot λ against 1/f; the gradient is the speed of sound v, since v = fλ [1]. Safety: keep the amplitude low to avoid exposure to loud sound [1]. [8] Examiner insight: Counting several wavelengths and plotting a graph both earn credit because they reduce uncertainty.

8. Circuit: lamp in series with an ammeter, voltmeter in parallel with the lamp [1], supplied through a variable resistor connected as a potential divider so the p.d. can start from 0 V [1]. Voltmeter range 0–20 V and ammeter range suited to the lamp, for example 0–1 A, chosen from the lamp’s rating [1]. Increase V in steps of about 1 V from 0 to 12 V, giving at least ten readings [1], and wait for each reading to settle as the filament heats [1]. Repeat with the supply connections reversed to obtain negative values [1]. Safety: the lamp becomes hot, so do not touch it until it has cooled [1]. Plot I against V; the curve shows how resistance V/I changes [1]. [8] Examiner insight: A potential divider is needed because a series variable resistor cannot reduce the p.d. to zero.

9. (a) Locating the centre of each spot on the screen [1]: measure between the same order on both sides of the centre and halve it [1]. Measuring the 1.5 m distance with a tape [1]: keep the tape taut and perpendicular to the screen, using a set square at the screen [1].
(b) The laser beam can damage the eye [1]: never look along the beam and remove reflective objects from the bench [1].
(c) Diffraction gratings are used in spectrometers to separate light into wavelengths [1], which lets scientists identify the elements present in a star or a sample from their spectral lines [1]. [8]

10. (a) Diameter: Vernier calipers or micrometer [1]; with Vernier, 0.05 ÷ 8 × 100% = 0.63% [1]. Length: metre rule [1]; 0.5 ÷ 500 × 100% = 0.1% [1]. Mass: top-pan balance reading to 0.1 g or better [1].
(b) Close the Vernier or micrometer jaws and check for a zero error, or check the balance reads zero with nothing on it [1]. [6]
Examiner insight: The diameter has the largest percentage uncertainty, so it deserves the most precise instrument and readings at several places.

11. Only three values of R [1]: use at least six, spread across the range [1]. The switch is closed throughout, so the cell warms and r changes [1]: open the switch between readings [1]. The voltmeter has a zero error of 0.05 V [1]: subtract 0.05 V from every reading or reset the zero [1]. r from one pair of readings [1]: plot V against I; the intercept gives ε and the gradient −r [1]. [8]

12. Calculate stress = F/A, where F = mg and A = πd²/4 from the mean diameter measured with a micrometer [1]. Calculate strain = extension ÷ original length [1]. Plot stress against strain [1]. The gradient of the straight-line region, below the limit of proportionality, is the Young modulus [1]. [4]

Where marks are usually lost

  • Naming an instrument without saying what it measures or its resolution.
  • Writing “be careful” instead of naming a hazard and a precaution.
  • Saying a series variable resistor can take the p.d. down to zero.
  • Measuring a single wavelength or a single spot distance instead of several.
  • Calculating a result from one pair of readings instead of a graph.
  • Ignoring a stated zero error.

Official syllabus

Pearson Edexcel International Advanced Subsidiary/Advanced Level in Physics, Issue 3, Unit 3, section 3.3 Planning.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.