Revision Notes
Edexcel International A Level Physics (YPH11): Unit 3 Planning – Revision Notes
Recall notes for Edexcel IAL Physics Unit 3 planning: plan frame, instrument choice, calibration, core practical controls and hazards, with a self-test.
- Subject
- Physics
- Level
- A LEVELS
- Topic
- Unit 3: Practical Skills in Physics I
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Hassan (what this means)
Aligned to Pearson Edexcel A Level Physics (YPH11), Issue 3. Official specification .
Syllabus page (what it covers and how it is assessed): Pearson Edexcel A Level Physics.
Syllabus points this page covers
YPH11
- 3.3 Planning
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Physics (YPH11).
Condensed notes for section 3.3 Planning, Unit 3: Practical Skills in Physics I, Pearson Edexcel IAL Physics (YPH11), Issue 3. For the full explanation and a worked plan, use the Unit 3 planning study guide; test yourself with the Unit 3 planning practice questions.
The plan frame
You plan an experiment Pearson sets; you do not carry it out. Write the answer in this order:
- Aim and physics: the equation linking the variables, if one is given or known.
- Variables: independent (changed), dependent (measured), controls (kept constant).
- Apparatus: every item, with range and resolution of each measuring instrument.
- Calibration: zero check or check against a known value.
- Method: numbered steps, with the technique for each measurement.
- Range and number: at least five or six values of the independent variable, spread widely.
- Repeats: whether appropriate, and why.
- Safety: hazard + precaution, specific to this apparatus.
- Data: what to plot, and how the gradient or intercept gives the answer.
- Uncertainty: main sources, and how each is reduced or eliminated.
- Implications and context: a benefit or risk, in a social, environmental or historical setting.
Instruments
| Instrument | Resolution | Uncertainty (single reading) | Best for |
|---|---|---|---|
| Metre rule | 1 mm | 0.5 mm | Lengths of 0.1 m to 1 m |
| Vernier calipers | 0.1 mm | 0.05 mm | Diameters of balls, rods, tubes, 5 mm to 150 mm |
| Micrometer screw gauge | 0.01 mm | 0.005 mm | Thin wires and sheets, below 25 mm |
| Stopwatch (hand timing) | 0.01 s display | Reaction time dominates, about 0.1 s to 0.2 s | Long intervals, many oscillations |
| Light gates and timer | Typically 0.001 s | Small | Short intervals, speeds |
| Top-pan balance | 0.01 g or 0.1 g | Half the resolution | Masses |
| Digital meter | Last digit | Half the last digit | Current, p.d. |
Choosing: calculate (half resolution ÷ quantity) × 100% for each option and pick the one well under 1–2%. Check the range: the quantity must fit the instrument.
Calibration checks
- Micrometer, Vernier: close the jaws; non-zero reading = zero error; subtract it from every reading.
- Meter: reads zero with nothing connected; adjust or subtract the offset.
- Newton-meter: hang a known mass; compare reading with mg.
- Signal generator: compare displayed frequency with f = 1/T from an oscilloscope trace.
- Thermometer: melting ice should read 0 °C.
Calibration removes systematic error. Repeats reduce random error. Neither does the other’s job.
Unit 1 and 2 core practicals: planning points
| Core practical | Key control | Main uncertainty and fix | Hazard and precaution |
|---|---|---|---|
| 1 Free fall | Same ball, same release method | Timing a short fall: use light gates or an electromagnet release and timer | Falling ball: catch box or sand tray |
| 2 Viscosity, falling ball | Liquid temperature, ball size and material | Ball not yet at terminal velocity: start timing well below the surface; parallax at markers | Spilt liquid: wipe up, slip risk |
| 3 Young modulus | Same wire, constant temperature | Small extension: long wire, fixed marker against a scale; diameter by micrometer at several places | Wire snapping: eye protection; masses falling: sand tray |
| 4 Speed of sound | Constant signal frequency | Locating in-phase positions: move through several wavelengths and divide | Loud sound: keep amplitude low |
| 5 Vibrating string | Length between bridges, same wire | Judging resonance: approach from above and below | Snapping wire: eye protection |
| 6 Laser and grating | Grating-to-screen distance | Locating spot centres: measure between orders on both sides | Laser: never look into the beam; remove reflective objects |
| 7 Resistivity | Wire temperature: small current, switch off between readings | Diameter: micrometer at several places and orientations | Hot wire: low current |
| 8 E.m.f. and internal resistance | Cell temperature: switch off between readings | Meter resolution: use the most sensitive range | Short circuit heating: include a protective resistor |
Repeats: when they help
- Help: readings that scatter randomly, such as hand timing, judging resonance, reading a swinging pointer.
- Do not help: a zero error; a digital reading that does not change; a length set by you with a rule (the set value is not a random measurement).
- With repeats: mean, then uncertainty = half the range.
Using the data
| Relationship | Plot | Answer from |
|---|---|---|
| s = ½gt² | s against t² | Gradient = g/2 |
| R = ρl/A | R against l | Gradient × A = ρ |
| f = (1/2l)√(T/μ) | f against √T | Gradient = 1/(2l√μ) |
| V = ε − Ir | V against I | Intercept = ε; gradient = −r |
| F = kx | F against x | Gradient = k |
Key terms
| Term | Meaning |
|---|---|
| Resolution | The smallest measuring interval of an instrument |
| Range (instrument) | The span of values an instrument can measure |
| Range (data) | Lowest to highest values of a variable used |
| Calibration | Checking an instrument against a known reference |
| Zero error | A non-zero reading when the true value is zero |
| Systematic error | An error that shifts every reading the same way |
| Random error | Unpredictable scatter about the true value |
| Control variable | A variable kept constant to make a fair test |
| Accuracy | How close a result is to the true value |
| Precision | How closely repeated values agree |
Exam traps
- Quoting resolution as uncertainty: the uncertainty of a single reading is half the resolution.
- “Repeat to remove systematic error”: wrong; calibrate instead.
- A safety line that names no hazard.
- Plotting y against x when the equation needs y against x² or √x.
- Forgetting the context point: it is on the Unit 3 list, not the Unit 6 list.
- Choosing a micrometer for a quantity larger than its range.
Self-test
1. State the resolution of a micrometer screw gauge. 2. What is the uncertainty in a single Vernier reading? 3. Which instrument is best for a 0.40 mm wire, and what percentage uncertainty does it give? 4. Why do repeat readings not remove a zero error? 5. How could you calibrate a newton-meter? 6. Give the control that matters most in a resistivity experiment, and how it is kept. 7. What graph gives g from a free-fall experiment with s and t measured? 8. Why are at least five or six values of the independent variable planned? 9. Give a hazard and precaution for the laser diffraction grating practical. 10. Repeated times are 2.46 s, 2.52 s and 2.49 s. Give the mean and its uncertainty. 11. Which planning point appears in Unit 3 but not in Unit 6? 12. In the vibrating-wire plan, why is f plotted against √T rather than T?
Answers
1. 0.01 mm. 2. Half of 0.1 mm, so 0.05 mm. 3. Micrometer: 0.005 ÷ 0.40 × 100% = 1.25%, about 1.3%. 4. A zero error shifts every reading by the same amount, so the mean is shifted too. 5. Hang a known mass and check the reading equals mg (for 0.200 kg, 1.96 N). 6. Wire temperature: use a small current and switch off between readings. 7. s against t²; the gradient is g/2. 8. So a line of best fit can be drawn with confidence and an anomalous point can be seen. 9. The beam can damage the eye: never look along it and remove reflective surfaces. 10. Mean 2.49 s; uncertainty (2.52 − 2.46) ÷ 2 = 0.03 s. 11. Implications and context of the physics; identifying sources of uncertainty and systematic error. 12. f ∝ √T, so f against √T is a straight line through the origin, which is easy to test.
Official syllabus
Pearson Edexcel International Advanced Subsidiary/Advanced Level in Physics, Issue 3, Unit 3, section 3.3 Planning.
Related resources
-
Practice questions
Edexcel IAL Physics: Electric Circuits — Practice Questions
Original practice questions with worked answers on drift velocity, resistivity, internal resistance and potential dividers for Edexcel IAL Physics (YPH11).
Physics · Pearson Edexcel · A Level
Try questions -
Study guides
Edexcel International A Level Physics (YPH11): Unit 3 Implementation and Measurements
Checking an inexperienced student's experiment for Edexcel IAL Physics Unit 3 section 3.4: readings, range, significant figures, anomalies and improvements.
Physics · Pearson Edexcel · A Level
Read guide -
Practice questions
Edexcel International A Level Physics (YPH11): Unit 3 Implementation and Measurements – Practice Questions
Twelve original questions on checking an inexperienced student's experiment, with mark-scheme answers, for Edexcel IAL Physics Unit 3 section 3.4.
Physics · Pearson Edexcel · A Level
Try questions
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.