Skip to content
Marlbridge

Revision Notes

Edexcel International A Level Physics (YPH11): Unit 6 Planning – Revision Notes

Recall notes for Edexcel IAL Physics Unit 6 planning: apparatus details, Unit 4 and 5 core practical controls and hazards, log graph forms and a self-test.

Subject
Physics
Level
A LEVELS
Topic
Unit 6: Practical Skills in Physics II
Updated

Aligned to Pearson Edexcel A Level Physics (YPH11), Issue 3. Official specification .

Syllabus page (what it covers and how it is assessed): Pearson Edexcel A Level Physics.

Syllabus points this page covers

YPH11

  • 6.3 Planning

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (YPH11).

Condensed notes for section 6.3 Planning, Unit 6: Practical Skills in Physics II, Pearson Edexcel IAL Physics (YPH11), Issue 3. Full teaching with two complete plans is in the Unit 6 planning study guide; questions are in the Unit 6 planning practice questions.

The seven 6.3 points in one line each

  1. Apparatus with details: the most appropriate items, with range, resolution and relevant dimensions or values.
  2. Calibration: zero check, or check against a known value.
  3. Measurement: the most appropriate instrument(s) and the technique for each variable.
  4. Controls: every other variable, and how it is kept constant.
  5. Repeats: whether appropriate, and why.
  6. Safety: a specific hazard and how it is dealt with.
  7. Data use: what is calculated, what is plotted, and how the answer comes from the graph.

Not on the 6.3 list (unlike Unit 3): implications and context; sources of uncertainty and systematic error (these are assessed in 6.5 Analysis).

Details that earn the apparatus marks

Choice Detail to give Reason
Time constant for hand timing RC of tens of seconds, for example 470 µF with 100 kΩ (47 s) Readings every 10 s are practical
Time constant below about 1 s Data logger or oscilloscope Too fast to read by eye
Mass–spring period At least 0.5 s; time 20 oscillations Reaction-time uncertainty becomes 2% or less
Heating experiment Temperature rise of at least 10 °C Thermometer uncertainty becomes a small fraction
Pendulum or spring amplitude Small, a few centimetres or under about 10° Keeps motion simple harmonic
Lead absorber Range of thicknesses up to about 20 mm, measured by micrometer Enough change in count rate to see the pattern
Light gates Card length measured with Vernier calipers Speed = card length ÷ time

Unit 4 and 5 core practicals: planning points

Core practical Key controls Hazard and precaution
9 Force and change of momentum Track tilted to compensate for friction; same trolley mass Falling masses: sand tray, feet clear
10 Collisions of small spheres analysed with ICT Level surface; camera fixed and perpendicular; scale in the frame Rolling balls: keep floor clear
11 Capacitor charge and discharge Same R and C; supply p.d. constant Electrolytic capacitor: connect with correct polarity, do not exceed its voltage rating
12 Thermistor calibrated in a potential divider as a thermostat Same supply p.d. and fixed resistor; stir water bath; wait for steady readings Hot water: scalding; keep electrical connections dry
13 Specific latent heat Same heater power; a control funnel without heater to measure melting from surroundings Hot heater: let it cool before handling
14 Pressure and volume of a gas Same mass of gas; wait after each change so temperature returns to room value Pressurised apparatus: eye protection, do not exceed the stated pressure
15 Absorption of gamma radiation by lead Fixed source-to-tube distance; same source and tube Ionising radiation: tongs, distance, short exposure, return to lead box; wash hands after lead
16 Unknown mass from oscillations Same spring; same small amplitude; vertical motion Falling masses or toppling stand: G-clamp, soft mat

Repeats

Situation Repeats appropriate? Why
Hand timing of oscillations Yes, about 3 Reaction time causes random error
Counting radioactive decays Yes, or count for longer Decay is random
Data logger recording many points Repeat runs rather than readings Each run already contains many readings
Reading a steady digital meter No Reading does not vary
Correcting a zero error No Systematic: correct it instead

Turning the equation into a graph

Relationship Plot Gradient Intercept
T = 2π√(m/k) T² against m 4π²/k Near zero (spring mass)
V = V₀e^(−t/RC) ln V against t −1/RC ln V₀
C = C₀e^(−μx) ln C against x −μ ln C₀
pV = constant p against 1/V The constant Zero
y = kxⁿ lg y against lg x n lg k
ΔE = mcΔθ (heater) Δθ against t P/mc Zero

Write the log form in the plan; it shows the examiner exactly what you will calculate.

Key terms

Term Meaning
Most appropriate apparatus The item whose range and resolution suit the size of the quantity
Relevant dimensions Sizes of apparatus that affect the result, such as string length or card length
Fiducial marker Fixed reference point used for timing oscillations
Background count Count from sources other than the one being studied
Corrected count rate Measured count rate minus background count rate
Time constant RC: time for a discharging capacitor’s p.d. to fall to 1/e of its initial value
Log graph A graph of ln y or lg y used to turn a curve into a straight line
Random process One whose outcome varies unpredictably, such as decay

Exam traps

  • Naming apparatus without values: Unit 6 asks for details.
  • Starting oscillation timing at the turning point instead of the equilibrium position.
  • Subtracting a background count recorded over a different time from a count; convert both to rates first.
  • Plotting V against t for a discharge and “finding RC from the curve” without a log graph.
  • Ignoring capacitor polarity or voltage rating in the safety section.
  • Writing a context or uncertainty paragraph instead of the data-use paragraph the marks are for.

Self-test

1. Which two Unit 3 planning points are not on the 6.3 list? 2. Why time 20 oscillations rather than one? 3. Where should the fiducial marker be placed for a mass on a spring, and why? 4. RC = 0.22 s. How should the discharge be recorded? 5. What graph tests whether count rate falls exponentially with lead thickness? 6. Background: 270 counts in 600 s. Reading: 1,350 counts in 100 s. Find the corrected count rate. 7. Why are repeats important in radioactivity experiments? 8. State two precautions when handling a sealed gamma source. 9. What is plotted to find k from a mass–spring experiment? 10. In the gas-law practical, why wait after each change of volume? 11. For y = kxⁿ, what does the gradient of lg y against lg x give? 12. Give one hazard specific to capacitor experiments.

Answers

1. Implications and context; sources of uncertainty and systematic error. 2. The reaction-time uncertainty becomes a small fraction of the total time. 3. At the equilibrium position, where the mass moves fastest, so the timing point is definite. 4. With a data logger or oscilloscope; it is too fast for hand timing. 5. ln (corrected count rate) against thickness. 6. Background 0.45 s⁻¹; reading 13.5 s⁻¹; corrected 13.05 s⁻¹, about 13.1 s⁻¹. 7. Decay is random, so counts in equal times vary. 8. Any two: tongs; hold at arm’s length pointing away from people; minimise time; return to its lead box. 9. T² against m; k = 4π² ÷ gradient. 10. Compression warms the gas; the temperature must return to the fixed value. 11. n. 12. An electrolytic capacitor can fail if connected the wrong way round or above its voltage rating.

Official syllabus

Pearson Edexcel International Advanced Subsidiary/Advanced Level in Physics, Issue 3, Unit 6, section 6.3 Planning.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.