Revision Notes
OxfordAQA A-Level Physics (9630): Hydroelectric power and pumped storage – Revision Notes
Revision notes for OxfordAQA 9630 section 3.13.4: turbine and generator, energy chain, water turbines, base and back-up stations and pumped storage.
- Subject
- Physics
- Level
- A LEVEL
- Topic
- Section 3.13 – Energy sources
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Iftikhar Azeemi (what this means)
Aligned to OxfordAQA A Level Physics (9630), International AS and A-level. Official specification .
Syllabus page (what it covers and how it is assessed): OxfordAQA A Level Physics.
Syllabus points this page covers
9630 (A Level)
- 3.13.4 Hydroelectric power and pumped storage
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Physics (9630).
These notes condense section 3.13.4, Hydroelectric power and pumped storage, of OxfordAQA International AS and A-level Physics (9630), part of Section 3.13 Energy sources (International A-level only). For explanations and worked examples, read the hydroelectric power study guide, then test yourself with the hydroelectric power practice questions. The wider unit is summarised in the wind, solar and hydroelectric energy revision notes.
Equations to know
| Equation | Use |
|---|---|
| mgh = ½mv², so v = √(2gh) | Speed of water after falling through head h, ignoring losses |
| Power available = ρQgh | Water at volume flow rate Q falling through head h |
| Maximum power = ½πr²ρv³ (ρ of water) | Turbine of blade length r in a stream of speed v |
| Energy stored = ρVgh | Volume V of water raised through head h |
| Energy to pump = stored energy ÷ pumping efficiency | Electrical input to fill the upper reservoir |
| Energy returned = stored energy × generating efficiency | Electrical output when emptying it |
| Round-trip efficiency = pumping efficiency × generating efficiency | Overall performance of pumped storage |
Density of water 1000 kg m⁻³; g = 9.81 N kg⁻¹.
Condensed recall
- Turbine: turned by moving water; kinetic energy of the water → kinetic energy of the shaft.
- Generator: coils rotate relative to a magnetic field; changing flux linkage induces an emf; kinetic energy → electrical energy.
- Energy chain: gravitational potential energy → kinetic energy of water → kinetic energy of turbine → electrical energy, with losses to friction, turbulence and heating.
- The kinetic energy delivered per second equals the potential energy lost per second when losses are ignored.
- ½πr²ρv³ is the same expression as for wind, with water’s density, about 800 times that of air: water turbines can be smaller for the same power.
- Base-power stations: run continuously at steady output to meet the constant minimum demand.
- Back-up stations: started when demand rises; must respond quickly. Hydroelectric stations reach full output within minutes.
- Pumped storage: at low demand, spare electricity pumps water uphill (stores gravitational potential energy); at high demand, water flows back through turbines to generate.
- Pumped storage is a store, not a source: it returns less energy than it uses. It lets base stations run steadily and can absorb surplus from intermittent sources.
Key terms
| Term | Meaning |
|---|---|
| Head | Vertical height through which the water falls |
| Penstock | Pipe carrying water from the reservoir to the turbine |
| Turbine | Machine turned by moving water |
| Generator | Machine that converts rotational kinetic energy into electrical energy by electromagnetic induction |
| Base-power station | Station run continuously to meet the minimum demand |
| Back-up power station | Station brought into use quickly when demand rises |
| Pumped storage | System that pumps water uphill to store energy and releases it to generate later |
| Round-trip efficiency | Electrical energy returned divided by electrical energy used for pumping |
Two kinds of water calculation
| Situation | Clue in the question | Equation |
|---|---|---|
| Water falling from a reservoir | Head h and flow rate Q (or mass per second) | ρQgh |
| Turbine in a river or tidal stream | Blade length r and current speed v | ½πr²ρv³ |
Exam traps
- Air density used for water, or the reverse.
- ρQgh and ½πr²ρv³ confused.
- Pumped storage called an energy source.
- Pumping energy found by multiplying by the efficiency instead of dividing.
- The turbine said to produce electricity; the generator does.
- Volumes left in litres; 1 m³ = 1000 litres.
Quick self-test
- State the function of the turbine and of the generator.
- Write the energy chain for a hydroelectric station.
- Find the speed of water after falling 20 m, ignoring losses.
- Find the power available from 12 m³ s⁻¹ of water falling through 50 m.
- Find the maximum power from a river turbine with 1.5 m blades in a 2.0 m s⁻¹ current.
- Why can a water turbine be much smaller than a wind turbine of the same power?
- What is a base-power station?
- Why are hydroelectric stations suitable as back-up stations?
- When does a pumped storage station pump, and when does it generate?
- Pumping is 80% efficient and generating 90% efficient. Find the round-trip efficiency.
- Find the energy stored when 2.0 × 10⁵ m³ of water is raised through 150 m.
- Why is pumped storage not an energy source?
Answers
- The turbine is turned by the moving water; the generator converts the turbine’s rotation into electrical energy.
- Gravitational potential energy → kinetic energy of water → kinetic energy of turbine → electrical energy.
- v = √(2 × 9.81 × 20) = 20 m s⁻¹ (19.8 m s⁻¹).
- P = 1000 × 12 × 9.81 × 50 = 5.9 × 10⁶ W.
- P = ½ × π × 1.5² × 1000 × 2.0³ = 2.8 × 10⁴ W.
- Water is about 800 times denser than air, so far more kinetic energy passes through each square metre each second at a given speed.
- A station that runs continuously at steady output to meet the minimum demand.
- They reach full output within minutes by opening valves; no fuel or boiler has to be heated.
- It pumps when demand is low and spare electricity is available; it generates when demand is high.
- 0.80 × 0.90 = 0.72, or 72%.
- E = 1000 × 2.0 × 10⁵ × 9.81 × 150 = 2.9 × 10¹¹ J.
- It only stores energy that was generated elsewhere, and returns less than it uses because of losses.
Official syllabus
OxfordAQA International AS and A-level Physics (9630), section 3.13.4 Hydroelectric power and pumped storage, published by OxfordAQA.
Related resources
-
Study guides
OxfordAQA A-Level Physics (9630): Solar energy
Study guide to OxfordAQA 9630 section 3.13.3: solar intensity, I = P/4πr², solar cell V-I curves, maximum power, arrays and Required practical 10.
Physics · OxfordAQA · A Level
Read guide -
Practice questions
OxfordAQA A-Level Physics (9630): Solar energy – Practice Questions
Original practice questions with mark-scheme answers on OxfordAQA 9630 section 3.13.3: inverse square law, V-I curves, arrays and Required practical 10.
Physics · OxfordAQA · A Level
Try questions -
Revision notes
OxfordAQA A-Level Physics (9630): Solar energy – Revision Notes
Revision notes for OxfordAQA 9630 section 3.13.3: solar intensity, I = P/4πr², V-I curves, arrays, Required practical 10 and a 12-question self-test.
Physics · OxfordAQA · A Level
Revise topic
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.