OxfordAQA A-Level Physics (9630): Limitation of physical measurements – Practice Questions
Twelve original OxfordAQA 9630 questions on 3.1.2: error types, repeat readings, combined uncertainties and gradient and intercept limits, with answers.
- Subject
- Physics
- Level
- AS LEVEL
- Topic
- Section 3.1 – Measurements and Their Errors
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Iftikhar Azeemi (what this means)
Aligned to OxfordAQA A Level Physics (9630), International AS and A-level. Official specification .
Syllabus page (what it covers and how it is assessed): OxfordAQA A Level Physics.
Syllabus points this page covers
9630 (AS Level)
- 3.1.2 Limitation of physical measurements
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Physics (9630).
These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers from your board or school.
These questions cover 3.1.2 Limitation of physical measurements of the OxfordAQA International AS and A-level Physics (9630) specification. It is International AS content, assessed in Unit 1 and used throughout Unit 5. Section A has short questions; Section B has longer, structured questions. All experimental data are invented for practice. If a point is unfamiliar, read the limitation of physical measurements study guide or the limitation of physical measurements revision notes first.
Questions
Section A
1. Explain the difference between an accurate set of measurements and a precise set of measurements. [2]
2. A student repeats a measurement several times and calculates the mean. Which type of error does this reduce?
A: a zero error
B: random error
C: systematic error from a miscalibrated meter
D: parallax error made the same way every time
[1]
3. A digital stopwatch displays times to 0.01 s. State its resolution, and explain why the uncertainty in a time measured by hand with this stopwatch is larger than its resolution. [2]
4. Five measurements of a wire’s diameter are 0.52 mm, 0.50 mm, 0.53 mm, 0.51 mm and 0.49 mm. Calculate the mean diameter, its absolute uncertainty and its percentage uncertainty. [3]
5. A quantity Z = X/Y². The percentage uncertainty in X is 2% and in Y is 3%. What is the percentage uncertainty in Z?
A: 1%
B: 5%
C: 8%
D: 11%
[1]
6. A calculated speed is 3.4167 m s⁻¹ with an absolute uncertainty of 0.0836 m s⁻¹. Write the result to an appropriate number of significant figures. [1]
7. Theory predicts that a straight-line graph should pass through the origin. A student’s best-fit line has an intercept that is well outside its uncertainty range from zero. Explain what this suggests. [2]
Section B
8. A student finds the thickness of one sheet of paper by measuring a stack of 200 sheets with vernier calipers. The stack is 19.6 ± 0.1 mm thick.
(a) Calculate the thickness of one sheet and its absolute uncertainty. [2]
(b) Measuring a single sheet with a micrometer gives 0.10 ± 0.01 mm. Use percentage uncertainties to explain why the stack method is better. [2]
(c) Suggest one systematic error that could affect the stack measurement and state its effect on the result. [2]
9. A trolley of mass 0.850 ± 0.005 kg passes through a light gate. A card of length 50.0 ± 0.5 mm on the trolley blocks the beam for 0.0625 ± 0.0005 s.
(a) Calculate the speed of the trolley and its absolute uncertainty. [3]
(b) Calculate the kinetic energy of the trolley and its absolute uncertainty. [3]
(c) State which measurement contributes most to the uncertainty in the kinetic energy. [1]
10. A spring has an unstretched length of 52 ± 1 mm. With a load of 4.00 ± 0.02 N it is 87 ± 1 mm long.
(a) Calculate the extension and its percentage uncertainty. [2]
(b) Calculate the spring constant and its absolute uncertainty. [3]
(c) Suggest one change to the method that would reduce the percentage uncertainty in the extension. [1]
11. A trolley is released from rest on a ramp. A student plots a graph of v² against distance travelled s; theory gives v² = 2as. From the graph (data invented for this question):
- best-fit line: gradient 1.36 m s⁻², intercept 0.004 m² s⁻²
- steepest acceptable line: gradient 1.45 m s⁻², intercept −0.010 m² s⁻²
- shallowest acceptable line: gradient 1.28 m s⁻², intercept 0.018 m² s⁻²
(a) Calculate the uncertainty in the gradient. [1]
(b) Determine the acceleration of the trolley with its absolute uncertainty. [2]
(c) Determine the uncertainty in the intercept and state what it shows about systematic error. [2]
12. A student measures the density of a small stone. The balance reads 45.62 g (resolution 0.01 g). The water level in a measuring cylinder, which has 1 cm³ divisions, rises from 50 cm³ to 67 cm³ when the stone is lowered in.
(a) Calculate the density of the stone in g cm⁻³ with its absolute uncertainty. [3]
(b) Evaluate the method and suggest two specific improvements. [3]
Answers
Section A
1. Accurate: the measurements (or their mean) are close to the true value [1]; precise: the measurements have very little spread about their mean [1] [2]
2. B [1] [1] Examiner insight: A, C and D are all systematic: they shift every reading the same way, so the mean is shifted too.
3. Resolution 0.01 s [1]; the experimenter’s reaction time in starting and stopping the watch varies and is much larger than 0.01 s [1] [2]
4. Mean = 2.55 ÷ 5 = 0.51 mm [1]; uncertainty = (0.53 − 0.49) ÷ 2 = ±0.02 mm [1]; percentage = 0.02 ÷ 0.51 × 100 = 3.9% [1] [3]
5. C [1] [1] Examiner insight: 2% + 2 × 3% = 8%. Option B forgets the square; dividing does not mean subtracting uncertainties.
6. 3.42 ± 0.08 m s⁻¹ [1] [1]
7. Every reading has been shifted by the same amount [1], which suggests a systematic error such as a zero error in one of the measured quantities [1] [2]
Section B
8.
(a) 19.6 ÷ 200 = 0.0980 mm [1]; 0.1 ÷ 200 = ±0.0005 mm [1]
(b) Stack: 0.1 ÷ 19.6 = 0.51% [1]; single sheet: 0.01 ÷ 0.10 = 10%, so the stack has a much smaller percentage uncertainty [1]
(c) Squeezing the stack with the calipers (or a zero error on the calipers) [1]; every measured thickness would be too small (or shifted by the zero error), so the result is inaccurate however often it is repeated [1] [6]
9.
(a) v = 0.0500 ÷ 0.0625 = 0.800 m s⁻¹ [1]; % uncertainty = 1.0% + 0.8% = 1.8% [1]; absolute = ±0.01 m s⁻¹ (0.014) [1]
(b) Ek = ½ × 0.850 × 0.800² = 0.272 J [1]; % uncertainty = 0.59% + 2 × 1.8% = 4.2% [1]; absolute = 0.011, so 0.27 ± 0.01 J [1]
(c) The card length (its 1.0% is doubled because v is squared) [1] [7]
Examiner insight: The mass uncertainty is the smallest term. Improving the balance would barely change the answer; a longer card would.
10.
(a) Extension = 87 − 52 = 35 mm, uncertainty 1 + 1 = ±2 mm [1]; percentage = 2 ÷ 35 × 100 = 5.7% [1]
(b) k = 4.00 ÷ 0.035 = 114 N m⁻¹ [1]; % uncertainty = 5.7% + 0.5% = 6.2% [1]; absolute = 7.1, so k = 114 ± 7 N m⁻¹ [1]
(c) Use a larger load to produce a larger extension (or use a pointer fixed to the spring and read the scale at eye level) [1] [6]
Examiner insight: Absolute uncertainties add for the difference even though the lengths are subtracted.
11.
(a) (1.45 − 1.28) ÷ 2 = 0.09 m s⁻² (0.085) [1]
(b) Gradient = 2a, so a = 1.36 ÷ 2 = 0.68 m s⁻² [1]; % uncertainty = 0.085 ÷ 1.36 = 6.3%, giving a = 0.68 ± 0.04 m s⁻² [1]
(c) (0.018 − (−0.010)) ÷ 2 = ±0.014 m² s⁻² [1]; the range 0.004 ± 0.014 includes zero, so there is no evidence of a systematic error [1] [5]
12.
(a) Volume = 67 − 50 = 17 cm³ with uncertainty ±2 cm³ (two readings) [1]; ρ = 45.62 ÷ 17 = 2.68 g cm⁻³ [1]; % uncertainty = 0.02% + 11.8% ≈ 12%, so ρ = 2.7 ± 0.3 g cm⁻³ [1]
(b) The volume dominates the uncertainty; the mass uncertainty is negligible [1]. Improvement 1: use a narrower measuring cylinder with finer divisions, or a larger stone, so the volume change is a larger number of divisions [1]. Improvement 2: read the bottom of the meniscus at eye level to avoid parallax, and check for trapped air bubbles, which would make the volume too large [1] [6]
Examiner insight: “Use a more accurate balance” scores nothing here. An improvement must target the measurement that controls the uncertainty.
Where marks are usually lost
- Treating zero errors and consistent parallax as random errors.
- Adding percentage uncertainties when lengths are subtracted.
- Forgetting the factor of 2 for a squared quantity.
- Quoting results with more significant figures than the uncertainty supports.
- Suggesting improvements to a measurement that is already precise.
- SI units and prefixes practice questions
- Estimation of physical quantities practice questions
- Measurements and their errors practice questions for the whole of Section 3.1
Specification reference
OxfordAQA International AS and A-level Physics (9630), for International AS and A-level exams May/June 2020 onwards: Section 3.1 Measurements and their errors (International AS), subtopic 3.1.2 Limitation of physical measurements.
Related resources
-
Revision notes
OxfordAQA A-Level Physics (9630): Limitation of physical measurements – Revision Notes
Condensed OxfordAQA 9630 notes on 3.1.2: error types, five precise measurement terms, uncertainty rules, worst-fit lines and a 12-question self-test.
Physics · OxfordAQA · AS Level
Revise topic -
Study guides
OxfordAQA A-Level Physics (9630): Use of SI units and their prefixes
OxfordAQA 9630 subtopic 3.1.1 in depth: SI base and derived units, the ten prefixes, standard form, and converting J to eV and J to kW h.
Physics · OxfordAQA · AS Level
Read guide -
Practice questions
OxfordAQA A-Level Physics (9630): Use of SI units and their prefixes – Practice Questions
Twelve original OxfordAQA 9630 questions on 3.1.1: base and derived units, prefix and area conversions, J to eV and J to kW h, with full answers.
Physics · OxfordAQA · AS Level
Try questions
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.