Skip to content
Marlbridge

Study Guides

OxfordAQA A-Level Physics (9630): Magnetic flux and flux linkage

Study guide to OxfordAQA 9630 section 3.10.3: Φ = BA, flux linkage NΦ, rotated coils with BANcosθ, reversals and flux linkage graphs for moving coils.

Subject
Physics
Level
A LEVEL
Topic
Section 3.10 – Magnetic fields
Updated

Aligned to OxfordAQA A Level Physics (9630), International AS and A-level. Official specification .

Syllabus page (what it covers and how it is assessed): OxfordAQA A Level Physics.

Syllabus points this page covers

9630 (A Level)

  • 3.10.3 Magnetic flux and flux linkage

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (9630).

This guide goes deeper into one subtopic of OxfordAQA International AS and A-level Physics (9630): section 3.10.3, Magnetic flux and flux linkage, in Section 3.10 Magnetic fields (International A-level only). For a first pass through 3.10.3 and 3.10.4 together, use the flux, flux linkage and electromagnetic induction study guide. After this page, condense it with the flux and flux linkage revision notes and test yourself with the flux and flux linkage practice questions.

What the specification asks for

Statement in 3.10.3 What you must be able to do
Magnetic flux defined by Φ = BA where B is perpendicular to A Define flux, use the weber, calculate Φ
Flux linkage as NΦ where N is the number of turns Calculate flux linkage for coils
Flux and flux linkage passing through a rectangular coil rotated in a magnetic field: NΦ = BANcosθ Use the angle correctly, find changes of flux linkage, and sketch NΦ against angle or time

Flux linkage matters because section 3.10.4 makes it the quantity whose rate of change gives the induced emf. Every induction calculation starts with a flux linkage calculation, so the marks lost here are lost twice.

Magnetic flux

Magnetic flux Φ through an area A is

Φ = BA, with B perpendicular to the area.

Think of B as the number of field lines per square metre, and Φ as the total number of lines passing through the area. Flux is measured in webers (Wb): 1 Wb = 1 T m². This also explains the name of B: flux density, in Wb m⁻².

Only the area that the field actually passes through counts. A large coil placed round a narrow magnetic field, such as the field inside a solenoid, has a flux equal to B × the area of the field, not B × the area of the coil.

Flux linkage

A coil of N turns has the same flux through each turn, so the total flux linkage is NΦ. Its unit is the weber, though “weber-turns” is often written to show that N has been included.

Coil Flux through each turn Flux linkage
1 turn of area A BA BA
N turns of area A BA BAN

The rotated coil: NΦ = BAN cos θ

θ is the angle between the field and the normal to the plane of the coil (the line at right angles to the coil’s face).

  • θ = 0°: the field passes straight through the face. NΦ = BAN, the maximum.
  • θ = 90°: the coil’s plane lies along the field; no lines pass through. NΦ = 0.
  • θ = 180°: the field passes through the face from the other side. NΦ = −BAN.

If a question gives the angle between the field and the plane of the coil, the angle to the normal is 90° minus that, so NΦ = BAN sin(angle to plane). Read which angle you have before substituting.

Worked example 1: a tilted circular coil

A circular coil of radius 2.5 cm and 150 turns sits in a uniform field of 0.040 T. The field makes an angle of 30° with the plane of the coil. Find the flux linkage.

A = π × 0.025² = 1.96 × 10⁻³ m².

The angle to the normal is 90° − 30° = 60°.

NΦ = BAN cos 60° = 0.040 × 1.96 × 10⁻³ × 150 × 0.50 = 5.9 × 10⁻³ Wb.

Using cos 30° by mistake gives 1.0 × 10⁻² Wb, which is wrong by a factor of √3.

Changes of flux linkage

Induced emf depends on how much the flux linkage changes, so questions often ask for Δ(NΦ).

Worked example 2: turning a coil over

The coil in worked example 1 is turned so that its face is perpendicular to the field, and then flipped through 180°.

Face perpendicular to the field (θ = 0°): NΦ = BAN = 0.040 × 1.96 × 10⁻³ × 150 = 1.18 × 10⁻² Wb.

After flipping, θ = 180°: NΦ = −1.18 × 10⁻² Wb.

Change = −1.18 × 10⁻² − (+1.18 × 10⁻²) = −2.4 × 10⁻² Wb, a magnitude of 2BAN.

The flux linkage has not just fallen to zero: it has reversed. Forgetting the reversal halves the change and the emf.

Other common changes:

Movement Change in flux linkage (magnitude)
θ from 0° to 90° BAN
θ from 0° to 60° BAN(1 − cos 60°) = 0.5 BAN
θ from 0° to 180° 2BAN
Coil removed from the field BAN cos θ
Field reversed 2BAN cos θ

Flux linkage graphs for a coil moving through a field

Worked example 3: a coil passing through a field region

A square coil of side 0.10 m and 20 turns moves at a constant 0.050 m s⁻¹ through a region 0.30 m wide where there is a uniform field of 0.20 T perpendicular to the coil. Outside this region there is no field. Describe how the flux linkage changes with time, starting as the leading edge enters.

Maximum flux linkage = BAN = 0.20 × 0.010 × 20 = 0.040 Wb.

  • 0 to 2.0 s: the coil enters. The area inside the field grows steadily (0.10 m of travel at 0.050 m s⁻¹ takes 2.0 s), so NΦ rises linearly from 0 to 0.040 Wb.
  • 2.0 s to 6.0 s: the whole coil is inside the field. The flux linkage is constant at 0.040 Wb. The leading edge reaches the far boundary at 0.30 / 0.050 = 6.0 s.
  • 6.0 s to 8.0 s: the coil leaves. NΦ falls linearly to zero.

The graph is a trapezium. In section 3.10.4, the emf is the gradient of this graph: 0.040 / 2.0 = 0.020 V while entering, zero while fully inside (even though the coil is moving), and 0.020 V in the opposite sense while leaving.

A rotating coil

A coil rotating at angular speed ω has θ = ωt, so NΦ = BAN cos ωt. The graph against time is a cosine curve between +BAN and −BAN, with period 2π/ω. The steepest parts, where the emf will be largest, occur where NΦ passes through zero, that is when the coil’s plane lies along the field.

Worked example 4: the area of the field, not the coil

A long solenoid has a uniform field of 0.012 T inside it and a cross-sectional area of 1.5 × 10⁻³ m². A coil of 200 turns and area 4.0 × 10⁻³ m² is wound round the outside of the solenoid. Find the flux linkage of the coil.

The field exists only inside the solenoid, so the flux through each turn is BA(solenoid) = 0.012 × 1.5 × 10⁻³ = 1.8 × 10⁻⁵ Wb.

NΦ = 200 × 1.8 × 10⁻⁵ = 3.6 × 10⁻³ Wb.

Using the coil’s own area gives an answer 2.7 times too big.

Common mistakes

  • Using the angle to the plane of the coil in BAN cos θ instead of the angle to the normal.
  • Forgetting N when flux linkage is asked for, or including it when flux is asked for.
  • Missing the sign change when a coil turns through 180°, so finding BAN instead of 2BAN.
  • Using the coil’s area when only part of the coil is in the field.
  • Leaving areas in cm²: 1 cm² = 10⁻⁴ m².
  • Thinking a coil moving inside a uniform field has a changing flux linkage. It changes only while the area in the field changes.

Exam technique

  • Define magnetic flux: Φ = BA, the product of flux density and the area perpendicular to the field. Name the weber.
  • Calculate a flux linkage: draw the normal on a sketch, mark θ to it, then write BAN cos θ.
  • Sketch NΦ against time or angle: label the maximum BAN, mark zeros, and keep the time axis to scale.
  • Explain a graph: link each section to what the coil is doing (entering, inside, leaving, or turning).

More resources on this topic

Official syllabus

OxfordAQA International AS and A-level Physics (9630), section 3.10.3 Magnetic flux and flux linkage, published by OxfordAQA. Check the board’s website for the current version of the specification.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.