Skip to content
Marlbridge

Practice Questions

OxfordAQA A-Level Physics (9630): Safety aspects of nuclear reactors – Practice Questions

Original practice questions with mark-scheme answers on OxfordAQA 9630 section 3.12.4: fuel handling, shielding, shut-down, decay heat, waste and risk.

Subject
Physics
Level
A LEVEL
Topic
Section 3.12 – Nuclear energy
Updated

Aligned to OxfordAQA A Level Physics (9630), International AS and A-level. Official specification .

Syllabus page (what it covers and how it is assessed): OxfordAQA A Level Physics.

Syllabus points this page covers

9630 (A Level)

  • 3.12.4 Safety aspects nuclear reactors

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (9630).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers from your board or school.

These questions cover section 3.12.4, Safety aspects of nuclear reactors, of OxfordAQA International AS and A-level Physics (9630), which is International A-level only content. Learn the content first with the reactor safety study guide and the reactor safety revision notes. Use 1 MeV = 1.60 × 10⁻¹³ J and take the specific heat capacity of water as 4200 J kg⁻¹ K⁻¹.

Questions

Section A: short questions

1. Explain why spent fuel is moved by remote handling. [2]

2. State two reasons why spent fuel is kept under water in a cooling pond. [2]

3. The control rods of a reactor are held above the core by electromagnets. Explain why this arrangement makes the reactor safer. [2]

4. The γ intensity from a small source is 5000 units at 1.0 m. Calculate the distance at which the intensity falls to 50 units. [2]

5. α particles are stopped by a sheet of paper. Explain why α-emitting waste is still treated as hazardous. [2]

6. Explain how the steel structure of a reactor becomes radioactive. [2]

Section B: structured questions

7. A container of high-level waste has an activity of 1.2 × 10¹⁶ Bq. Each decay deposits on average 0.60 MeV in the container.

(a) Calculate the rate at which thermal energy is produced in the container. [2]

(b) Suggest why the container must be kept in a cooled store. [1]

(c) The activity is mainly due to a nuclide of half-life 30.1 years. Calculate the activity after 10 years. [2]

(d) Calculate the heating power after 10 years. [1]

8. A reactor operating at 2.0 GW of thermal power is shut down in an emergency. Just after shut-down, decay heating is 5.0% of the operating power.

(a) Calculate the decay heating power. [1]

(b) Calculate the mass of cooling water needed each second if the water may warm by 25 K. [2]

(c) Explain why the control rods are designed to fall into the core under gravity. [2]

(d) State a second, independent way of stopping the chain reaction. [1]

9. (a) Name the three categories of radioactive waste and give one example of each. [3]

(b) Explain why high-level waste is stored for several years before any long-term disposal. [2]

(c) Suggest why deep underground storage in stable rock is planned for long-lived waste. [1]

10. Spent fuel contains strontium-90 (half-life 28.8 years) and plutonium-239 (half-life 24 100 years).

(a) Calculate the fraction of the strontium-90 that remains after 100 years. [2]

(b) Calculate the time for the activity of the plutonium-239 to fall to 1.0% of its initial value. [2]

(c) State what your answers suggest about how the two nuclides must be stored. [1]

11. (a) Explain why the thick concrete shield around a reactor core is not needed to stop α and β particles. [2]

(b) Explain why reactor shielding uses both dense materials and materials containing light nuclei. [2]

(c) A worker 2.0 m from a small γ source is exposed to an intensity I. Calculate the distance at which the intensity would be I/25. [1]

12. A country must choose between building a new nuclear power station and a new coal-fired power station to supply continuous electricity. Discuss the risks and benefits of the nuclear option compared with the coal option, and reach a conclusion. [6]

Answers

1. Spent fuel emits intense β and γ radiation (and is hot) [1]; workers close to it would receive a dangerous dose, so machines controlled from behind shielding move it [1] [2]

2. The water absorbs the radiation, shielding workers [1]; the water removes the heat produced by radioactive decay [1] [2]

3. If electrical power fails, the electromagnets release the rods [1], which fall into the core under gravity, absorbing neutrons and stopping the chain reaction without needing any power supply [1] [2]

4. I ∝ 1/r², so r² = 1.0² × 5000/50 = 100 [1]; r = 10 m [1] [2]

5. If α-emitting material escapes and is breathed in or swallowed [1], the α particles deposit their energy in a small volume of tissue inside the body, causing severe damage [1] [2]

6. Neutrons from the core are absorbed by nuclei in the steel [1], producing unstable (radioactive) isotopes [1] [2]

7. (a) Power = activity × energy per decay = 1.2 × 10¹⁶ × 0.60 × 1.60 × 10⁻¹³ [1] = 1.2 × 10³ W [1]

(b) The decay heat is produced continuously and would raise the temperature of the container and its contents until they were damaged [1]

(c) A = A₀e^(−λt) with λ = ln 2/30.1 y⁻¹ [1]; A = 1.2 × 10¹⁶ × e^(−0.693 × 10/30.1) = 9.5 × 10¹⁵ Bq [1]

(d) 9.5 × 10¹⁵ × 0.60 × 1.60 × 10⁻¹³ = 9.2 × 10² W [1] [6]

Examiner insight: Ten years is not a whole number of half-lives, so the exponential equation is needed.

8. (a) 0.050 × 2.0 × 10⁹ = 1.0 × 10⁸ W [1]

(b) Δm/Δt = P/(cΔθ) [1] = 1.0 × 10⁸/(4200 × 25) = 9.5 × 10² kg s⁻¹ [1]

(c) The shut-down then works even if electrical power or control systems fail [1]; gravity always acts, so the rods enter the core and absorb neutrons automatically [1]

(d) Inject a neutron-absorbing liquid (for example a boron solution) into the coolant [1] [6]

9. (a) Low-level, for example protective clothing or tools [1]; intermediate-level, for example fuel cladding or reactor components [1]; high-level, for example spent fuel or separated fission products [1]

(b) Its activity and heat output are very high at first [1]; many fission products have short half-lives, so storage allows the activity and heating to fall before the waste is sealed for disposal [1]

(c) Stable rock deep underground isolates the waste from people and from groundwater for the very long times over which it remains hazardous [1] [6]

10. (a) A/A₀ = e^(−λt) = e^(−0.693 × 100/28.8) [1] = 0.090 [1]

(b) t = ln(A₀/A)/λ = ln 100 × 24 100/0.693 [1] = 1.6 × 10⁵ years [1]

(c) Strontium-90 needs secure storage for centuries; plutonium-239 needs isolation for hundreds of thousands of years [1] [5]

11. (a) α and β particles have short ranges and are stopped by the fuel cladding and the steel pressure vessel [1]; the concrete is needed for the penetrating radiations, neutrons and γ rays [1]

(b) Dense materials (steel, concrete) absorb γ rays [1]; light nuclei (in water and concrete) slow neutrons by collisions so they can be absorbed [1]

(c) I ∝ 1/r², so the distance must be multiplied by 5: 10 m [1] [5]

12. Marking points, one mark each, up to 6 [6]:

  • Benefit: nuclear fuel releases far more energy per kilogram, so fuel quantities and transport are small [1]
  • Benefit: no carbon dioxide is released by the reactor during operation, unlike burning coal [1]
  • Benefit: coal combustion also releases air pollutants; nuclear generation does not [1]
  • Risk: a rare accident could release radioactive material over a wide area [1]
  • Risk: long-lived high-level waste must be isolated for thousands of years; decommissioning is costly [1]
  • Conclusion weighing these, for example: both give continuous output, but nuclear power avoids the certain, continuing harm from carbon dioxide and pollution in exchange for a low-probability but severe risk that can be reduced by design, shielding and waste management, so nuclear is preferred (another reasoned conclusion is accepted) [1]

Examiner insight: The final mark requires a conclusion that follows from the points made; a list without a judgement cannot reach full marks.

Where marks are usually lost

  • Saying control rods cool the reactor.
  • Forgetting that decay heat continues after shut-down.
  • Using the inverse-square law with r instead of r².
  • Treating 10 years as a whole number of half-lives.
  • Listing risks and benefits without reaching a conclusion.

More on this topic

Official syllabus

OxfordAQA International AS and A-level Physics (9630), section 3.12.4 Safety aspects of nuclear reactors, published by OxfordAQA.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.