Skip to content
Marlbridge

Study Guides

AQA A-Level Chemistry (7405): Calorimetry

AQA 7405 calorimetry in depth: q = mc delta T, molar enthalpy from solution and combustion experiments, units and significant figures, heat loss, uncertainty and improving the method.

Subject
Chemistry
Level
A LEVEL (AS CONTENT)
Topic
Energetics
Updated

Aligned to AQA A Level Chemistry (7405), For teaching from September 2015. Official specification .

Syllabus page (what it covers and how it is assessed): AQA A Level Chemistry.

Syllabus points this page covers

7405 (AS content of the A Level)

  • 3.1.4.2 Calorimetry

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Chemistry (7405).

This guide teaches section 3.1.4.2 Calorimetry of the AQA AS and A-level Chemistry specification (7404/7405), for teaching from September 2015. It is AS content, examined on Papers 1 and 2 (and Paper 3). It also supports Required practical 2, the measurement of an enthalpy change. The equation q = mcΔT is simple. The marks are lost in the setup: using the right mass, the right amount in moles, the right units and sign, and evaluating the errors in the experiment. The Energetics study guide covers the full topic. Recall is in the Calorimetry revision notes, and questions are in the Calorimetry practice questions.

What the specification asks

Content and skills What you must be able to do
q = mcΔT, where m is the mass of the substance that has a temperature change ΔT and a specific heat capacity c Use the equation with correct units
Calculate the molar enthalpy change for a reaction Convert q into kJ mol⁻¹ with the right sign
Use the equation in related calculations For example, find c, a mass, or a temperature rise
You will not be expected to recall the value of c Use the value given in the question
Required practical 2 Plan, carry out and evaluate an enthalpy measurement
Report answers to an appropriate number of significant figures Limit the answer to the least precise measurement

The equation and its units

q = m × c × ΔT
q   heat energy transferred   J
m   mass                      g
c   specific heat capacity    J g⁻¹ K⁻¹  (water: 4.18, given)
ΔT  temperature change        K or °C (the size of a change is the same)

Specific heat capacity is the energy needed to raise the temperature of 1 g of a substance by 1 K.

The most important point is which mass to use. It is the mass of the substance whose temperature is measured, which is usually the water or solution, not the mass of the reactants you weighed (such as the magnesium or the fuel). For dilute aqueous solutions, assume the density is 1.00 g cm⁻³, so 50.0 cm³ of solution has a mass of 50.0 g.

From q to the molar enthalpy change

  1. Calculate q in joules.
  2. Convert to kJ (÷ 1000).
  3. Calculate the amount in moles of the substance that reacted (the limiting reagent, or the substance named in the question).
  4. ΔH = q ÷ n, in kJ mol⁻¹.
  5. Add the sign: negative if the temperature rose (exothermic), positive if it fell (endothermic).

Worked example 1: neutralisation

50.0 cm³ of 1.00 mol dm⁻³ HCl is added to 50.0 cm³ of 1.00 mol dm⁻³ NaOH in a polystyrene cup. The temperature rises by 6.8 °C. Calculate the enthalpy change per mole of water formed. (c = 4.18 J g⁻¹ K⁻¹; density 1.00 g cm⁻³)

m = 100 g (total solution)
q = 100 × 4.18 × 6.8 = 2842 J = 2.842 kJ
n(HCl) = 1.00 × 0.0500 = 0.0500 mol  (equal to n(H₂O) formed)
ΔH = −2.842 ÷ 0.0500 = −56.8 kJ mol⁻¹

The temperature rose, so ΔH is negative. To two significant figures (ΔT is 6.8) the answer is −57 kJ mol⁻¹.

Worked example 2: an endothermic dissolving

4.00 g of ammonium nitrate (Mᵣ = 80.0) is dissolved in 50.0 g of water. The temperature falls by 7.0 °C. Calculate the enthalpy change of solution per mole.

q = 50.0 × 4.18 × 7.0 = 1463 J = 1.463 kJ
n = 4.00 ÷ 80.0 = 0.0500 mol
ΔH = +1.463 ÷ 0.0500 = +29.3 kJ mol⁻¹

The temperature fell, so heat was absorbed and ΔH is positive. The mass used is that of the water (50.0 g). Some courses add the mass of the solid; follow the question.

Worked example 3: a displacement reaction

25.0 cm³ of 1.00 mol dm⁻³ copper(II) sulfate solution is stirred with excess zinc powder, and the temperature rises by 45.0 °C. Calculate ΔH per mole of copper(II) sulfate.

q = 25.0 × 4.18 × 45.0 = 4702 J = 4.702 kJ
n(CuSO₄) = 1.00 × 0.0250 = 0.0250 mol   (zinc is in excess, so CuSO₄ is limiting)
ΔH = −4.702 ÷ 0.0250 = −188 kJ mol⁻¹

The amount in moles comes from the limiting reagent and not from the excess zinc.

Combustion calorimetry

For a fuel such as an alcohol, the heat from burning is transferred to a known mass of water in a metal can (a calorimeter).

Worked example 4: burning ethanol

A spirit burner containing ethanol heats 100 g of water in a copper can. The temperature rises from 21.0 °C to 33.5 °C. The mass of the burner falls by 0.46 g. (Mᵣ of ethanol = 46.0; c = 4.18 J g⁻¹ K⁻¹)

ΔT = 12.5 °C
q = 100 × 4.18 × 12.5 = 5225 J = 5.225 kJ
n(ethanol) = 0.46 ÷ 46.0 = 0.0100 mol
ΔH = −5.225 ÷ 0.0100 = −523 kJ mol⁻¹

The data-book value for the enthalpy of combustion of ethanol is −1367 kJ mol⁻¹, so this result is only about 38 per cent of it. This is typical of simple apparatus, for the reasons below.

Why experimental values are less exothermic than data-book values

Source of error Effect on measured ΔH
Heat lost to the surroundings, the air and the can Temperature rise is too small, so the value is less negative
Incomplete combustion (soot, CO) Less heat released per mole than for complete combustion
Evaporation of the fuel from the wick The mass loss is greater than the mass burned, so n is too large and ΔH too small
Non-standard conditions (not 298 K or 100 kPa; water vapour rather than liquid) The product is not in its standard state, so the value differs
Heat absorbed by the apparatus, such as the can Water receives less heat than was released

Improvements: use a lid or draught shield; put the burner close to the can; stir the water; insulate the can; use a bomb calorimeter for better accuracy; repeat and average.

Solution calorimetry: practical points

  • Use an insulated vessel, such as a polystyrene cup with a lid, to reduce heat loss.
  • Measure the starting temperature for a few minutes first.
  • Add the second reagent, stir, and record temperature at regular intervals.
  • For better results, plot temperature against time and extrapolate the cooling curve back to the time of mixing to find the maximum temperature rise, because the reaction is not instantaneous and heat is lost while it takes place.

Uncertainty and significant figures

Each temperature reading has an uncertainty. A thermometer read to ±0.1 °C used twice (initial and final) gives ΔT an uncertainty of ±0.2 °C. For a rise of 6.8 °C the percentage uncertainty is 0.2 ÷ 6.8 × 100 = 2.9%.

A mass reading on a balance read to ±0.01 g has a percentage uncertainty of 0.01 ÷ 0.46 × 100 = 2.2% for 0.46 g.

Round the final answer to the number of significant figures of the least precise value used, or one more.

Common mistakes

  • Using the mass of the reactant, instead of the mass of the water or solution, in q = mcΔT.
  • Leaving q in joules while ΔH is in kJ mol⁻¹.
  • Forgetting the sign: exothermic needs a negative ΔH.
  • Using the total volume in the n = cV step instead of the volume of the limiting reagent.
  • Saying “heat loss” without saying which direction it affects the answer.
  • Writing “human error” as an improvement or a source of error.
  • Using the temperature, not the temperature change.

Exam technique for the command words

  • Calculate: show q, the amount in moles, the division and the sign, with the units.
  • Suggest a reason for the difference from the data-book value: give heat loss or incomplete combustion and say how it changes the result.
  • Suggest an improvement: name a specific change (lid, insulation, stirring, draught shield) and say what it does.
  • Evaluate: give the percentage uncertainty and compare sources of error.

Frequently asked questions

Does it matter if I use K or °C for ΔT? No. The size of a change is the same. A temperature itself must be in K only when used in equations such as pV = nRT.

Why not use the mass of the acid and alkali separately? Because the temperature change applies to the whole solution. Add the volumes (and assume 1.00 g cm⁻³) unless told otherwise.

Is the specific heat capacity of water always 4.18? It is given in the question. Use the value in the question.

Official syllabus

AQA, AS and A-level Chemistry specification (7404/7405), for AS and A-level exams June 2016 onwards: section 3.1.4.2 Calorimetry.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.