Revision Notes
AQA A-Level Chemistry (7405): pH curves, titrations and indicators – Revision Notes
Condensed AQA 7405 notes on pH curves: the four curve shapes, choosing indicators, titration calculations, Required practical 9, exam traps and a self-test.
- Subject
- Chemistry
- Level
- A LEVEL
- Topic
- Acids and bases
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Nouman Ahmed (what this means)
Aligned to AQA A Level Chemistry (7405), For teaching from September 2015. Official specification .
Syllabus page (what it covers and how it is assessed): AQA A Level Chemistry.
Syllabus points this page covers
7405 (A Level)
- 3.1.12.5 pH curves, titrations and indicators
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Chemistry (7405).
These notes condense section 3.1.12.5 pH curves, titrations and indicators of the AQA AS and A-level Chemistry specification (7404/7405), for teaching from September 2015. It is A-level only content, examined on Paper 1 and Paper 3. Explanations and worked examples are in the pH curves, titrations and indicators study guide, and exam-style questions are in the pH curves, titrations and indicators practice questions. The wider topic is in the Acids and bases revision notes.
What you must be able to do
- Perform titration calculations from experimental results.
- Sketch and explain the pH curves for all combinations of weak and strong monoprotic acids and bases.
- Select an appropriate indicator from a pH curve.
- Describe Required practical 9: pH changes when a weak acid reacts with a strong base and a strong acid with a weak base.
Key terms
| Term | Meaning |
|---|---|
| pH curve | Graph of pH against volume of titrant added |
| Equivalence point | Amounts of acid and base are in the ratio of the equation |
| End point | Where the indicator changes colour |
| Vertical section | Region of rapid pH change around equivalence |
| Buffer region | Part of a weak acid or weak base curve where pH changes slowly |
| Half-equivalence | Half the equivalence volume; pH = pKa for a weak acid |
| Indicator | Weak acid HIn whose colour differs from that of In⁻ |
The four curves at a glance
Flask: 25.0 cm³ of 0.100 mol dm⁻³; titrant 0.100 mol dm⁻³; equivalence at 25.0 cm³.
| Combination | Start pH | Vertical section | pH at equivalence | Suitable indicator |
|---|---|---|---|---|
| Strong acid + strong base | 1 | about 3.7 to 10.3 | 7 | Methyl orange or phenolphthalein |
| Weak acid + strong base | about 2.9 | about 7 to 10 | about 8.7 | Phenolphthalein |
| Strong acid + weak base | about 11 | about 7 to 4 | about 5.3 | Methyl orange |
| Weak acid + weak base | varies | none | about 7 | None; use a pH meter |
Reasons for the equivalence pH:
- Weak acid + strong base: the anion of the weak acid is a base, so the salt solution is alkaline (CH₃COO⁻ + H₂O ⇌ CH₃COOH + OH⁻).
- Strong acid + weak base: the cation is a weak acid, so the salt solution is acidic (NH₄⁺ ⇌ NH₃ + H⁺).
Reading a curve
- Starting pH: strong acid is low (about 1); weak acid is higher (about 3).
- Buffer region (weak acid or weak base only): a gentle slope.
- Half-equivalence: pH = pKa of the weak acid (or of the conjugate acid of the weak base).
- Vertical section: mid-point is the equivalence volume.
- End: the pH approaches that of the excess titrant.
Indicators
| Indicator | Colour change | Range |
|---|---|---|
| Methyl orange | Red to yellow | 3.1 to 4.4 |
| Phenolphthalein | Colourless to pink | 8.3 to 10.0 |
Rule: the indicator range must fall inside the vertical section.
Reasons for the wrong choices:
- Methyl orange with a weak acid and strong base: it changes colour in the buffer region, long before equivalence.
- Phenolphthalein with a strong acid and weak base: it changes colour after the vertical section has ended, in the buffer region.
Titration calculations
- n(titrant) = c × V (V in dm³).
- Use the equation ratio to find n(sample).
- c(sample) = n ÷ V(sample).
- Scale up for any dilution.
Examples:
25.0 cm³ NaOH, mean titre 22.40 cm³ of 0.100 mol dm⁻³ HCl
n(HCl) = 0.100 × 0.02240 = 2.24 × 10⁻³ mol
c(NaOH) = 2.24 × 10⁻³ ÷ 0.0250 = 0.0896 mol dm⁻³
Ba(OH)₂ + 2HCl → BaCl₂ + 2H₂O
18.20 cm³ of 0.100 mol dm⁻³ HCl with 25.0 cm³ Ba(OH)₂
n(HCl) = 1.82 × 10⁻³ mol, n(Ba(OH)₂) = 9.10 × 10⁻⁴ mol
c = 9.10 × 10⁻⁴ ÷ 0.0250 = 0.0364 mol dm⁻³
If the sample was diluted (for example 25.0 to 250 cm³), multiply the final concentration by the dilution factor (10).
Ka from half-equivalence
At half-equivalence [HA] = [A⁻], so Ka = [H⁺] and pH = pKa. If pH = 4.35 at half-equivalence, Ka = 10^(–4.35) = 4.47 × 10⁻⁵ mol dm⁻³.
Required practical 9
- Calibrate the pH meter with buffer solutions before use.
- Add titrant in 1 cm³ portions, then in drops near the vertical section.
- Stir and record the pH after each addition; plot pH against volume.
- Find the equivalence point from the mid-point of the vertical section.
- Rinse the electrode between measurements.
Exam traps
- Same vertical section for every titration.
- Choosing an indicator by colour rather than by pH range.
- Using methyl orange for a weak acid with a strong base.
- Starting a weak acid curve at pH 1.
- Forgetting the buffer region.
- Equivalence pH given as 7 for all combinations.
- Not halving moles for Ba(OH)₂ or doubling for H₂SO₄.
- Ignoring a dilution factor.
- Weak–weak: suggesting an indicator.
- Using pH = pKa at any point, not just at half-equivalence.
Self-test
- What is the pH at equivalence for strong acid + strong base at 298 K?
- Give the approximate pH at equivalence for ethanoic acid + sodium hydroxide, and the reason.
- Which indicator suits strong acid + weak base?
- Which indicator suits weak acid + strong base?
- State the rule for choosing an indicator.
- What is the relationship between pH and pKa at half-equivalence?
- 25.0 cm³ of NaOH needs 20.00 cm³ of 0.100 mol dm⁻³ HCl. Calculate c(NaOH).
- Why is there no suitable indicator for weak acid + weak base?
- Why is the buffer region flat?
- Why is the starting pH of a weak acid higher than for a strong acid of equal concentration?
- What does the equivalence point mean?
- Why add alkali in drops near the vertical section?
Answers
- 7.00.
- About 8.7; ethanoate is a base, so the solution is alkaline.
- Methyl orange.
- Phenolphthalein.
- The indicator’s pH range must lie within the vertical section of the curve.
- They are equal.
- n(HCl) = 2.00 × 10⁻³ mol; c = 2.00 × 10⁻³ ÷ 0.0250 = 0.0800 mol dm⁻³.
- There is no vertical section, so no sharp colour change.
- The flask contains a weak acid and its salt, which resist pH change.
- A weak acid is only partly dissociated, so [H⁺] is lower.
- The moles of acid and base are in the ratio in the balanced equation.
- The pH changes rapidly there, so small additions are needed to locate the mid-point.
Official syllabus
AQA, AS and A-level Chemistry specification (7404/7405), for AS and A-level exams June 2016 onwards: section 3.1.12.5 pH curves, titrations and indicators, and Required practical 9.
Related resources
-
Study guides
AQA A-Level Chemistry (7405): The ionic product of water, Kw
AQA 7405 Kw in depth: deriving Kw from the dissociation of water, calculating the pH of strong bases, the effect of temperature and what neutral means at other temperatures.
Chemistry · AQA · A Level
Read guide -
Practice questions
AQA A-Level Chemistry (7405): The ionic product of water, Kw – Practice Questions
Original AQA 7405 questions with marked answers on Kw: the expression and units, pH of strong bases, concentration from pH, temperature effects and neutral water.
Chemistry · AQA · A Level
Try questions -
Revision notes
AQA A-Level Chemistry (7405): The ionic product of water, Kw – Revision Notes
Condensed AQA 7405 notes on Kw: definition and units, pH of strong bases, temperature effects, neutral water at other temperatures, exam traps and a self-test.
Chemistry · AQA · A Level
Revise topic
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.