Skip to content
Marlbridge

Practice Questions

Cambridge A Level Information Technology (9626): Control technologies – Practice Questions

Twelve original Cambridge 9626 IT section 3.2 questions with answers: control sensors, actuators, named systems, a control algorithm and a trace table.

Subject
ICT
Level
AS LEVEL
Topic
Topic 3 – Monitoring and control
Updated

Aligned to Cambridge A Level Information Technology (9626), 2025-2027. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge A Level Information Technology.

Syllabus points this page covers

9626 (AS Level)

  • 3.2 Control technologies

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Information Technology (9626).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs; examination boards hold copyright in their own papers. Use these alongside the official past papers available free from your board.

Related: Control technologies study guide | Control technologies revision notes

These questions are for section 3.2 Control technologies (Topic 3, AS Level) of Cambridge International AS & A Level Information Technology (9626), 2025–2027. Algorithms use the pseudocode style of section 4.1. All organisations and figures are invented.


Section A

1. State the function of an actuator and give one example. [2]

2. Explain how an induction loop is used in a car park barrier system. [2]

3. Explain why touch sensors are used in devices that detect the cooling water level in a nuclear power plant. [2]

4. Identify the type of actuator used in each case: bus doors opened by compressed air; road bollards raised by pressurised oil; a door held shut by an electromagnet. [3]

5. Explain what is meant by feedback in a control system. [2]

6. Explain one advantage of using a Wireless Sensor and Actuator Network to water a large orchard. [2]

Section B

7. A central heating system keeps a room at 20 °C.

(a) Describe how the system does this. [4]

(b) Explain one disadvantage of computer-controlled central heating. [2]

8. An office air-conditioning system switches cooling on when the temperature is above 25 °C and off when it is below 23 °C. Fans run when the humidity is above 60% and stop otherwise. The system runs until it is switched off. Write an algorithm for this system. [6]

9. A greenhouse checks soil moisture five times a day using this algorithm.

Minutes ← 0
FOR Check ← 1 TO 5
    READ Moisture from moisture sensor
    IF Moisture < 35 THEN
        Open water valve for 10 minutes
        Minutes ← Minutes + 10
    ENDIF
NEXT Check
PRINT Minutes

The readings are 40, 30, 33, 36 and 20. Complete a trace table and state the output. [4]

10. Describe how a computer-controlled burglar alarm uses sensors to protect a house. [5]

11. Explain how sensors and computer control are used on a smart motorway. [4]

12. Evaluate the use of computer control in a large commercial greenhouse. [6]


Answers

1. An actuator turns a signal from the microprocessor into physical movement or action [1], for example a motor that opens a greenhouse vent [1]. [2]

2. A loop of wire is buried in the road in front of the barrier, and the car’s metal body changes its magnetic field [1]; the microprocessor detects this change, knows a car is waiting, and raises the barrier [1]. [2]

3. The probe detects whether water is touching it at a set level [1]; if the water falls below the probe, the system immediately starts pumps or raises an alarm, preventing overheating without needing a person to check [1]. [2]

4. Pneumatic [1]; hydraulic [1]; magnetic [1]. [3]

5. The result of the system’s action changes the next sensor reading [1], and the system uses that reading to decide its next action, for example switching the heater off once the room warms [1]. [2]

6. Sensors and actuators communicate without cables, so they can be spread across the whole orchard cheaply [1], and each area can be watered only when its own soil is dry, saving water [1]. [2]

7. (a) A temperature sensor measures the room temperature continuously [1]. The reading is converted to digital and compared by the microprocessor with the preset 20 °C [1]. If it is below 20 °C, a signal switches the boiler and pump on; if above, they are switched off [1]. The sensor keeps reading, so the system responds to the effect of its own action [1].

(b) If the sensor fails or is badly placed, for example near a sunny window, the system acts on wrong readings [1], so the room could become too cold or waste energy [1]. [6]

8. Example algorithm:

REPEAT
    READ Temp from temperature sensor
    IF Temp > 25 THEN
        Switch cooling on
    ELSE
        IF Temp < 23 THEN
            Switch cooling off
        ENDIF
    ENDIF
    READ Humidity from humidity sensor
    IF Humidity > 60 THEN
        Switch fans on
    ELSE
        Switch fans off
    ENDIF
    INPUT Power
UNTIL Power = 0

Marking: a loop with a way to end [1]; temperature read inside the loop [1]; cooling on above 25 [1]; cooling off below 23, with no change in between [1]; humidity read and fans switched on above 60 and off otherwise [1]; correct structure with each IF closed by ENDIF [1]. [6]

9. Trace:

Check Moisture Valve opened? Minutes
1 40 No 0
2 30 Yes 10
3 33 Yes 20
4 36 No 20
5 20 Yes 30

Checks 1 and 4 correct [1]; checks 2 and 3 correct [1]; check 5 correct [1]; output 30 [1]. [4]

10. When the alarm is set, the microprocessor reads its sensors continuously [1]. Infrared sensors detect the body heat of a person moving in a room [1]; magnetic field sensors on doors and windows detect when a magnet moves away as they open [1]; sound sensors detect breaking glass [1]. If any sensor is triggered, the system starts an entry delay and, if the code is not entered, sounds the siren or alerts a monitoring company [1]. [5]

11. Sensors such as induction loops in the road measure traffic speed and flow [1]. The data is sent to a control centre computer [1], which compares it with preset values and sets variable speed limits on overhead signs to smooth traffic [1]. After an incident it can close a lane by displaying a closure sign, keeping traffic away from the hazard [1]. [4]

12. Advantages: conditions are kept within precise limits day and night, improving crop growth [1]; watering and heating happen only when needed, saving water and energy [1]; fewer staff are needed for routine checks [1]. Disadvantages: high installation and maintenance cost [1]; a faulty sensor could cause over-watering or overheating that damages a whole crop [1]. Conclusion: worthwhile for a large commercial greenhouse because savings and better yields over many crops outweigh the cost, provided sensors are maintained and an alarm warns staff of faults [1]. [6]

Where marks are usually lost

  • Reading the sensor once, before the loop starts.
  • Using one threshold when the question gives two values.
  • Leaving out the actuator signal, so the algorithm decides but never acts.
  • Skipping rows in a trace table or recording values that did not change.
  • Describing a monitoring system when asked about control.