Cambridge A Level Information Technology (9626): Monitoring and measurement technologies – Practice Questions

Twelve original Cambridge 9626 IT section 3.1 questions with answers: sensors, humidity, water and patient monitoring, and calibration calculations.

Subject
ICT
Level
AS LEVEL
Topic
Topic 3 – Monitoring and control
Updated

Aligned to Cambridge A Level Information Technology (9626), 2025-2027. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge A Level Information Technology.

Syllabus points this page covers

9626 (AS Level)

  • 3.1 Monitoring and measurement technologies

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Information Technology (9626).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs; examination boards hold copyright in their own papers. Use these alongside the official past papers available free from your board.

Related: Monitoring and measurement study guide | Monitoring and measurement revision notes

These questions are for section 3.1 Monitoring and measurement technologies (Topic 3, AS Level) of Cambridge International AS & A Level Information Technology (9626), 2025–2027. All organisations and figures are invented.


Section A

1. State what a pH sensor measures and give one use of it in environmental monitoring. [2]

2. Identify two gases that a gas sensor may detect and give a reason for monitoring each. [4]

3. Define relative humidity. [2]

4. Explain what is meant by the sampling interval, and suggest a suitable interval for monitoring a patient’s heart rate in intensive care. [2]

5. Explain why calibration is important for sensors used in patient monitoring. [2]

6. State what is meant by ambient temperature. [1]

Section B

7. A humidity sensor in a museum reads 47% relative humidity when an accurate reference instrument reads 45%.

(a) State the offset that should be applied to the sensor’s readings. [1]

(b) The sensor later reads 62%. Calculate the corrected reading. [1]

(c) Explain one limitation of using one-point calibration for this sensor. [2]

8. A temperature sensor is calibrated using two reference points. It reads 2.4 in a mixture of ice and water and 101.6 in boiling water at standard atmospheric pressure.

(a) Explain why these two references are used. [2]

(b) Calculate the corrected value of a raw reading of 40.0, to one decimal place. Show your working. [3]

9. A gas sensor is checked at four reference values.

True value 0 20 40 60
Raw reading 1.0 19.0 38.5 61.0

(a) Calculate the corrected value of a raw reading of 30.0, to one decimal place. [3]

(b) Explain why multipoint calibration is more suitable than two-point calibration for this sensor. [2]

10. An environment agency wants to monitor a river downstream of a factory. Describe how a computerised monitoring system would do this. [6]

11. A hospital plans to replace hourly manual checks of patients’ vital signs with computerised monitoring. Evaluate this plan. [6]

12. A weather station is installed on a remote mountain. Explain how its sensors are used and why the readings are collected automatically. [4]


Answers

1. The acidity or alkalinity of a liquid [1]; for example, detecting chemical pollution in a river or lake [1]. [2]

2. Any two, each with a reason: carbon monoxide [1], because it is poisonous and has no smell, so dangerous levels in homes or car parks must be detected [1]; oxides of nitrogen [1], to measure roadside air pollution from vehicle exhausts [1]; also accept oxygen (dissolved oxygen for fish health) or carbon dioxide (air quality in classrooms). [4]

3. The amount of water vapour in the air as a percentage [1] of the maximum it could hold at that temperature [1]. [2]

4. The time between one reading and the next [1]; for example, every second, because heart rate can change dangerously within seconds [1]. [2]

5. Sensors drift over time, so readings become inaccurate [1]; inaccurate readings could cause wrong treatment or a missed alarm, putting the patient at risk [1]. [2]

6. The temperature of the surrounding air [1]. [1]

7. (a) −2 percentage points (subtract 2 from every reading) [1].

(b) 62 − 2 = 60% [1].

(c) It assumes the error is the same at every humidity [1]; if the sensor has a slope error, readings far from 45% will still be wrong, so two-point or multipoint calibration would be better [1]. [4]

8. (a) Their true temperatures are known accurately and are easy to reproduce: 0 °C and 100 °C [1]; they sit at the low and high ends of the range, so both offset and slope can be corrected [1].

(b) Raw range = 101.6 − 2.4 = 99.2 [1]; corrected = (40.0 − 2.4) × 100 ÷ 99.2 [1] = 37.9 °C [1]. [5]

9. (a) 30.0 lies between 19.0 (true 20) and 38.5 (true 40) [1]; corrected = 20 + (30.0 − 19.0) × 20 ÷ (38.5 − 19.0) [1] = 31.3 [1].

(b) The sensor’s errors are not consistent: it under-reads in the middle of the range and over-reads at the top [1], so its response is not a straight line and a line through only two points would leave errors elsewhere [1]. [5]

10. Sensors for pH, temperature and dissolved oxygen are placed in the river below the factory outflow [1]. Readings are taken automatically at a set interval, such as every 15 minutes, day and night [1]. Analogue signals are converted to digital by an analogue-to-digital converter [1] and sent, for example wirelessly, to a computer [1]. The computer stores the readings with the time and displays them as graphs [1], and compares them with preset limits, alerting staff if a reading shows pollution [1]. [6]

11. Advantages: readings are continuous rather than hourly, so a sudden change is spotted at once [1]; alarms sound immediately [1]; nurses spend less time taking readings and more on care [1]. Disadvantages: equipment is costly to buy and maintain [1]; false alarms when sensors slip can cause staff to ignore alarms [1]. Conclusion: worthwhile for patients whose condition can change quickly, provided staff still observe patients and sensors are calibrated regularly [1]. [6]

12. Temperature, pressure, humidity and light sensors take readings of the air, atmospheric pressure, water vapour and sunlight [1] at regular intervals and store them [1]. Collection is automatic because the site is remote and hard to reach, especially in bad weather [1], and readings are needed continuously, day and night, which people could not provide [1]. [4]

Where marks are usually lost

  • Describing an automatic response when the question is about monitoring.
  • Leaving out the analogue-to-digital converter in a system description.
  • Applying an offset with the wrong sign.
  • Using the two end points when the reading falls between two closer calibration points.
  • Confusing absolute and relative humidity.