Cambridge A Level Information Technology (9626): Monitoring and measurement technologies – Revision Notes

Revision notes for Cambridge 9626 IT section 3.1: sensors, weather and water monitoring, patient monitoring, humidity and calibration methods, with a self-test.

Subject
ICT
Level
AS LEVEL
Topic
Topic 3 – Monitoring and control
Updated

Aligned to Cambridge A Level Information Technology (9626), 2025-2027. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge A Level Information Technology.

Syllabus points this page covers

9626 (AS Level)

  • 3.1 Monitoring and measurement technologies

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Information Technology (9626).

These notes condense section 3.1 Monitoring and measurement technologies (Topic 3 Monitoring and control) of the Cambridge International AS & A Level Information Technology 9626 syllabus for 2025, 2026 and 2027. AS Level content, examined in Paper 1 Theory. Worked calibration examples are in the monitoring and measurement study guide; test yourself with the monitoring and measurement practice questions.

The monitoring chain

Sensor → analogue-to-digital converter → computer stores, displays and compares readings with limits → warning to a person. No automatic action: that would be control (3.2).

Choose a sampling interval (time between readings) and a period (how long monitoring lasts).

Sensors named in 3.1

Sensor Measures Monitoring example
Light/UV Light intensity; UV level Sunlight at weather stations
Temperature Heat Ambient air; body temperature; river water
Pressure Force Atmospheric pressure; blood pressure
Humidity Water vapour in air Weather stations; museums
pH Acidity River and lake pollution
Gas Oxygen, carbon dioxide, carbon monoxide, oxides of nitrogen Dissolved oxygen in rivers; air quality; roadside pollution
Sound Noise level Airports, building sites
Infrared Infrared radiation, body heat Contact-free temperature; detecting people
Touch Contact Checking a probe is in contact
(Electro)magnetic field Field strength Detecting vehicles or metal objects
Proximity Closeness without contact How near an object is

Key terms

Term Meaning
Monitoring Measuring and recording values for people to review, with warnings but no automatic action
Analogue-to-digital converter Turns a sensor’s continuous signal into digital data
Sampling interval Time between readings
Ambient temperature Temperature of the surrounding air
Atmospheric pressure Pressure exerted by the air
Absolute humidity Mass of water vapour in a volume of air, such as g/m³
Relative humidity Water vapour as a percentage of the maximum the air could hold at that temperature
Calibration Checking readings against known reference values and adjusting so they are accurate
Drift Gradual change in a sensor’s accuracy over time
Offset A constant amount by which all readings are wrong
Slope (gain) error Error that grows as the measured value rises

Environmental monitoring: recall

  • Water pollution: pH (chemical pollution), temperature (warm discharges), dissolved oxygen (sewage, fertiliser). Logs day and night, catching short events with exact times.
  • Weather stations: ambient temperature (shaded, ventilated sensor), atmospheric pressure (falling: unsettled; rising: settled), humidity (absolute and relative), light (sunshine strength and hours). Data sent to a central computer.
  • Warmer air can hold more water, so the same absolute humidity gives lower relative humidity on a warmer day.

Patient monitoring: recall

  • Measures heart rate, blood pressure, body temperature, blood oxygen, breathing rate.
  • Displays, stores and alarms when a value leaves the limits set for that patient.
  • Advantages: continuous, instant alarms, frees nurses, no human error or tiredness, one nurse watches many patients.
  • Disadvantages: cost, false alarms and alarm fatigue, over-reliance, misleading readings from faulty or uncalibrated sensors.

Calibration: recall

Method Reference points Corrects Use when
One-point 1 Offset only Constant error, or used near one value
Two-point 2 (low and high) Offset and slope Straight-line response over a wide range
Multipoint 3 or more Non-linear errors Curved response, or high accuracy across the range

Formulas.

  • One-point: corrected = raw + offset.
  • Two-point: corrected = low reference + (raw − raw at low) × (high reference − low reference) ÷ (raw at high − raw at low).

Quick example: pH sensor. Buffer solutions of pH 4.00 and 7.00 read 4.20 and 7.10. A raw reading of 6.00 is corrected to 4 + (6.00 − 4.20) × 3 ÷ 2.90 = 5.86.

Temperature references: ice and water (0 °C) and boiling water (100 °C at standard atmospheric pressure).

Exam traps

  • Monitoring answers that describe automatic actions.
  • Mixing up absolute and relative humidity.
  • Saying calibration increases sensitivity rather than accuracy.
  • One-point calibration for a sensor with a slope error.
  • Forgetting the analogue-to-digital converter in a system description.
  • Generic sensors: “a sensor detects the weather” earns nothing.

Self-test

  1. What is the difference between monitoring and control?
  2. Why is an analogue-to-digital converter needed?
  3. Name three sensors used in a weather station and what each measures.
  4. Distinguish absolute and relative humidity.
  5. Which three readings would show pollution in a river?
  6. Give two advantages of computerised patient monitoring.
  7. Give one disadvantage of computerised patient monitoring.
  8. Why must sensors be calibrated regularly?
  9. What does one-point calibration correct, and what does it not?
  10. A sensor reads 2 at 0 °C and 96 at 100 °C. What is the corrected value of a raw reading of 50?
  11. When is multipoint calibration needed?
  12. Why is a weather station’s temperature sensor shaded?

Answers

  1. Monitoring records values and warns a person; control acts automatically on the readings.
  2. Sensors give analogue signals, but the computer can only process digital data.
  3. Any three: temperature (ambient air), pressure (atmospheric), humidity (water vapour), light (sunlight).
  4. Absolute: mass of water vapour per volume of air. Relative: water vapour as a percentage of the maximum the air could hold at that temperature.
  5. pH, temperature and dissolved oxygen.
  6. Any two: continuous readings, instant alarms, frees nurses, no human error, one nurse can watch several patients.
  7. Any one: false alarms, cost, over-reliance, misleading readings from faulty sensors.
  8. Sensors drift over time, and decisions depend on accurate readings.
  9. It corrects a constant offset; it does not correct a slope error.
  10. (50 − 2) × 100 ÷ 94 = 51.1 °C.
  11. When the sensor’s response is not a straight line, or high accuracy is needed across the full range.
  12. So direct sunlight does not heat the sensor and it measures the air temperature, not the sun’s heating.