Cambridge A Level Physics (9702): Production and use of X-rays – Practice Questions

Original practice questions with mark-scheme answers on Cambridge A Level Physics 9702 24.2 X-rays: minimum wavelength, attenuation, contrast and CT scanning.

Subject
Physics
Level
A LEVEL
Topic
Medical physics
Updated

Aligned to Cambridge A Level Physics (9702), 2025-2027. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge A Level Physics.

Syllabus points this page covers

9702 (A Level)

  • 24.2 Production and use of X-rays

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (9702).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs — examination boards hold copyright in their own papers. Use these alongside the official past papers available free from your board.

Related: X-rays study guide · X-rays revision notes

Use h = 6.63 × 10⁻³⁴ J s, c = 3.00 × 10⁸ m s⁻¹ and e = 1.60 × 10⁻¹⁹ C. Attenuation coefficients are illustrative values: soft tissue 20 m⁻¹, bone 60 m⁻¹.


Section A

1. State how the electrons in an X-ray tube are released from the cathode. [1]

2. An X-ray tube operates with an accelerating p.d. of 30 kV.

(a) Calculate the maximum energy of an X-ray photon produced, in joules. [1]

(b) Calculate the minimum wavelength of the X-rays. [1]

3. Explain why the minimum wavelength of the X-rays from a tube does not change when the tube current is increased. [2]

4. State what is meant by contrast in an X-ray image. [1]

5. Calculate the fraction of the intensity of an X-ray beam that is transmitted through 4.0 cm of soft tissue. [1]

6. Calculate the thickness of bone that reduces the intensity of an X-ray beam to half its initial value. [2]


Section B

7. An X-ray tube operates at 90 kV with a tube current of 8.0 mA.

(a) Calculate the number of electrons striking the target each second. [1]

(b) Calculate the power delivered to the target by the electron beam. [1]

(c) About 1 % of this power is emitted as X-rays. Calculate the power emitted as X-rays. [1]

(d) Suggest why the anode of the tube is made to rotate. [1]

8. The operator of an X-ray tube can change the accelerating p.d. and the filament current.

(a) The p.d. is increased from 40 kV to 80 kV. State the effect on the minimum wavelength. [1]

(b) Explain the effect of increasing the filament current on the X-ray beam, at constant p.d. [2]

9. An X-ray beam passes through a limb. Beam A passes through 10.0 cm of soft tissue only. Beam B passes through 7.0 cm of soft tissue and 3.0 cm of bone.

(a) Calculate the fraction of the incident intensity transmitted along path A. [1]

(b) Calculate the fraction of the incident intensity transmitted along path B. [2]

(c) Calculate the ratio of the two transmitted intensities, and comment on the contrast in the image. [1]

10. Blood vessels are difficult to see on an ordinary X-ray image.

(a) Explain why. [1]

(b) Explain how injecting a contrast medium containing iodine allows the blood vessels to be seen. [2]

11. (a) Describe how a CT scanner produces a three-dimensional image of an internal structure. [4]

(b) State one advantage of a CT image over a single X-ray image. [1]

12. The intensity of an X-ray beam falls to 25 % of its initial value after passing through 2.3 cm of a material. Calculate the attenuation coefficient of the material. [2]

13. Calculate the accelerating p.d. needed to produce X-rays with a minimum wavelength of 3.1 × 10⁻¹¹ m. [2]


Answers

1. By thermionic emission from a heated filament [1].

2. (a) E = eV = 1.60 × 10⁻¹⁹ × 30 × 10³ = 4.8 × 10⁻¹⁵ J [1].

(b) λ_min = hc/E = 6.63 × 10⁻³⁴ × 3.00 × 10⁸ ÷ 4.8 × 10⁻¹⁵ = 4.1 × 10⁻¹¹ m [1].

3. The minimum wavelength is set by the maximum photon energy, which equals the kinetic energy eV of one electron [1]; increasing the current increases the number of electrons per second, but not the energy of each, which depends only on the p.d. [1].

4. The difference in degree of blackening (brightness) between different areas of the image [1].

5. I/I₀ = e^(−20 × 0.040) = 0.45 [1].

6. ½ = e^(−60x) [1]; x = ln 2 ÷ 60 = 0.012 m (1.2 cm) [1].

7. (a) 8.0 × 10⁻³ ÷ 1.60 × 10⁻¹⁹ = 5.0 × 10¹⁶ [1].

(b) P = VI = 90 × 10³ × 8.0 × 10⁻³ = 720 W [1].

(c) 0.01 × 720 = 7.2 W [1].

(d) About 99 % of the power becomes thermal energy in the target; rotating the anode spreads the heating over a larger area so the target does not melt [1].

8. (a) The minimum wavelength halves [1].

(b) More electrons are released per second, so more electrons strike the target per second [1]; the beam has a greater intensity (more photons per second), but the photon energies and minimum wavelength are unchanged [1].

9. (a) e^(−20 × 0.100) = e^(−2.0) = 0.14 [1].

(b) I/I₀ = e^(−(20 × 0.070 + 60 × 0.030)) [1] = e^(−3.2) = 0.041 [1].

(c) 0.135 ÷ 0.041 = 3.3; the intensities behind the two paths are very different, so the bone gives good contrast against the soft tissue [1].

10. (a) Blood and the surrounding soft tissue have similar attenuation coefficients, so they transmit similar intensities and there is little contrast [1].

(b) Iodine has a large attenuation coefficient [1], so blood containing it absorbs X-rays much more than the surrounding tissue, giving a large difference in transmitted intensity (high contrast) [1].

11. (a) X-ray images of the same thin section are taken from many different angles as the source and detectors rotate around the patient [1]. A computer combines these to produce a 2D image of that section [1]. The process is repeated for further sections along an axis through the body [1]. The 2D images of the sections are combined to give a 3D image [1].

(b) Any one [1]: structures do not overlap as they do in a single image; the image can be viewed from any angle or as any slice; soft tissues with similar attenuation can be distinguished more easily.

12. 0.25 = e^(−μ × 0.023) [1]; μ = ln 4 ÷ 0.023 = 60 m⁻¹ [1].

13. V = hc/(eλ_min) [1] = 6.63 × 10⁻³⁴ × 3.00 × 10⁸ ÷ (1.60 × 10⁻¹⁹ × 3.1 × 10⁻¹¹) = 4.0 × 10⁴ V (40 kV) [1].


Where marks are usually lost

  • Forgetting to convert kilovolts to volts before using λ_min = hc/(eV).
  • Linking the minimum wavelength to the tube current or the target metal.
  • Using thickness in cm with an attenuation coefficient in m⁻¹.
  • Multiplying attenuation coefficients for two layers instead of adding the μx terms.
  • Describing contrast as the sharpness or clarity of the image.
  • CT descriptions that omit “same section from different angles” or “repeated along an axis”.