Revision Notes
Cambridge A Level Physics (9702): Production and use of X-rays – Revision Notes
Revision notes for Cambridge A Level Physics 9702 24.2 X-rays: the X-ray tube, λ_min = hc/eV, contrast, attenuation and CT, with a self-test.
- Subject
- Physics
- Level
- A LEVEL
- Topic
- Medical physics
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Hassan (what this means)
Aligned to Cambridge A Level Physics (9702), 2025-2027. Official specification .
Syllabus page (what it covers and how it is assessed): Cambridge A Level Physics.
Syllabus points this page covers
9702 (A Level)
- 24.2 Production and use of X-rays
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Physics (9702).
Subtopic 24.2 of Cambridge International AS & A Level Physics 9702 (2025–2027) covers the production of X-rays by electron bombardment, the minimum wavelength, contrast in X-ray images, exponential attenuation and computed tomography. These notes are condensed for recall. For full explanations and worked examples, read the X-rays study guide; to apply the ideas, try the X-rays practice questions.
Equations
kinetic energy of each electron = eV
λ_min = hc / (eV) (one electron → one photon, all its energy)
I = I₀ e^(−μx) (recall)
layers: I = I₀ e^(−(μ₁x₁ + μ₂x₂))
number of electrons per second = I_tube / e
The X-ray tube
| Part | Function |
|---|---|
| Heated cathode (filament) | Releases electrons by thermionic emission; filament current sets beam intensity |
| High p.d. | Accelerates electrons; sets maximum photon energy |
| Metal target (e.g. tungsten) | Electrons decelerate in it and emit X-ray photons |
| Cooling / rotating anode | Removes heat: about 99 % of the electron energy becomes thermal energy |
| Vacuum | No collisions with gas molecules |
Minimum wavelength: the reasoning
- Electrons lose energy in one or many interactions, so photon energies form a continuous range.
- The most energetic photon takes all of one electron’s kinetic energy eV.
- So hc/λ_min = eV.
- λ_min depends only on the accelerating p.d.
| p.d. / kV | λ_min / m |
|---|---|
| 25 | 4.97 × 10⁻¹¹ |
| 50 | 2.49 × 10⁻¹¹ |
| 80 | 1.55 × 10⁻¹¹ |
| 100 | 1.24 × 10⁻¹¹ |
Contrast
- Contrast = difference in degree of blackening (brightness) between areas of the image.
- Good when neighbouring structures have very different μ (bone and soft tissue).
- Poor between soft tissues with similar μ.
- Improve it with a contrast medium of high μ (barium compound swallowed; iodine compound injected) or a suitable choice of X-ray energy.
Attenuation reminders
- μ depends on the material and the photon energy; bone has larger μ than soft tissue.
- For several layers, add the μx terms in the exponent (or multiply the separate factors).
- Thickness halving the intensity = ln 2 / μ (for μ = 20 m⁻¹: 3.5 cm; for μ = 60 m⁻¹: 1.2 cm).
CT scanning in four stages
- X-ray source and detectors rotate; many images of one section taken from different angles.
- Computer combines them into a 2D image of that section.
- Patient moved along an axis; repeated for many sections.
- 2D images of all sections combined into a 3D image.
Key terms
| Term | Meaning |
|---|---|
| Electron bombardment | Firing high-energy electrons at a metal target |
| Thermionic emission | Release of electrons from a heated metal |
| Minimum wavelength | Shortest X-ray wavelength produced; set by accelerating p.d. |
| Hard X-rays | High photon energy, short wavelength, more penetrating |
| Attenuation coefficient μ | Constant in I = I₀e^(−μx) for a given material and photon energy |
| Contrast | Difference in degree of blackening between regions of the image |
| Contrast medium | Substance with large μ introduced into the body to improve contrast |
| Computed tomography | Building a 3D image from 2D section images, each from many X-ray images |
Exam traps
- Leaving the p.d. in kV in λ_min = hc/(eV).
- Using the power of the tube instead of eV as the photon energy.
- Saying λ_min depends on the target material or tube current.
- Mixing up contrast and sharpness.
- Using x in cm with μ in m⁻¹.
- Describing CT without the “same section, different angles” and “repeated along an axis” stages.
- Claiming X-rays are reflected by bone; they are attenuated (absorbed and scattered).
Self-test
- How are the electrons in an X-ray tube released?
- What happens to most of the energy of the electrons hitting the target?
- Explain why the X-ray spectrum has a minimum wavelength.
- Calculate λ_min for a tube operating at 120 kV.
- What p.d. gives λ_min = 2.0 × 10⁻¹¹ m?
- A tube current is 4.0 mA. How many electrons hit the target each second?
- Define contrast in an X-ray image.
- Why is a barium compound used when imaging the stomach?
- X-rays pass through 1.5 cm of bone with μ = 60 m⁻¹. What fraction is transmitted?
- How is the intensity transmitted through two different layers calculated?
- List the stages by which CT produces a 3D image.
- Why do two soft tissues show poor contrast on an X-ray image?
Answers: 1. Thermionic emission from a heated filament (cathode). 2. It becomes thermal energy in the target. 3. The highest-energy photon is produced when an electron gives all its kinetic energy eV to one photon, so no photon can have a shorter wavelength than hc/(eV). 4. 6.63 × 10⁻³⁴ × 3.00 × 10⁸ / (1.60 × 10⁻¹⁹ × 1.20 × 10⁵) = 1.04 × 10⁻¹¹ m. 5. V = hc/(eλ) = 6.2 × 10⁴ V (62 kV). 6. 4.0 × 10⁻³ / 1.60 × 10⁻¹⁹ = 2.5 × 10¹⁶. 7. The difference in degree of blackening between different areas of the image. 8. It has a large attenuation coefficient, so it shows the outline of the stomach clearly against surrounding soft tissue. 9. e^(−60 × 0.015) = 0.41. 10. I = I₀e^(−(μ₁x₁ + μ₂x₂)), or multiply the two transmitted fractions. 11. Many images of one section from different angles; combined into a 2D image of the section; repeated for sections along an axis; 2D images combined into 3D. 12. Their attenuation coefficients are similar, so similar intensities pass through each.
More resources on this topic
- Medical Physics revision notes — the whole of Topic 24
- X-rays practice questions
- Ultrasound revision notes — subtopic 24.1
- PET scanning revision notes — subtopic 24.3
Related resources
-
Study guides
Medical Physics
Ultrasound and acoustic impedance, X-ray production and attenuation, CT scanning and PET annihilation photons: Topic 24 of Cambridge A Level Physics 9702.
Physics · Cambridge · A Level
Read guide -
Practice questions
A Level Physics: Medical Physics — Practice Questions
Original exam-style practice questions with full worked answers on ultrasound, X-rays, attenuation and PET scanning for A Level Physics.
Physics · Cambridge · A Level
Try questions -
Revision notes
A Level Physics: Medical Physics — Revision Notes
Condensed recall notes on ultrasound, X-rays, attenuation, CT scanning and PET for Cambridge AS & A Level Physics 9702.
Physics · Cambridge · A Level
Revise topic
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.