Cambridge IGCSE Physics (0625): Electrical safety – Practice Questions

Twelve original Cambridge IGCSE Physics 0625 electrical safety questions: hazards, wiring, fuse ratings, trip switches and earthing, with answers.

Subject
Physics
Level
IGCSE
Topic
Electricity and magnetism
Updated

Aligned to Cambridge IGCSE Physics (0625), For examination in 2026, 2027 and 2028. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge IGCSE Physics.

Syllabus points this page covers, with Core and Extended

0625

  • 4.4 Electrical safety · Core

"Core and Extended" means part of that syllabus point is Extended only. The page's own tier notes say which part.

Found an error? Report a correction.

Need help with this topic? Request a free trial class for IGCSE Physics (0625).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – Cambridge International holds copyright in its own papers. Use these alongside the official past papers available from your board.

These questions cover section 4.4 Electrical safety of the Cambridge IGCSE Physics 0625 syllabus for examination in 2026, 2027 and 2028. Take the mains supply as 230 V.

Tier note: all of section 4.4 is Core content, so every question here is for every candidate. The marks shown are indicative only.

Related: electrical safety study guide and electrical safety revision notes.


Section A

1. Name the wire in a mains circuit that is connected to the metal casing of an appliance. [1]

2. State the two dangers that damaged insulation on a mains cable can cause. [2]

3. Explain why using mains appliances in damp conditions is hazardous. [1]

4. State one difference between the way a fuse and a trip switch break a circuit. [1]

5. State what is meant by the rating of a fuse. [1]

Section B

6. An electrician finds that a ceiling lamp has been wired with its switch in the neutral wire.

(a) Explain why the lamp still goes off when the switch is opened. [1]
(b) Explain why this wiring is dangerous. [2]

7. A toaster is rated at 800 W.

(a) Calculate the normal current in the toaster. [2]
(b) Fuses rated at 3 A, 5 A and 13 A are available. Choose the most suitable fuse and explain your choice. [2]
(c) Explain the danger of fitting the 13 A fuse instead. [2]

8. A 2.0 kW heater, a 1.2 kW iron and a 150 W television are all plugged into one extension lead designed for a maximum current of 13 A.

(a) Calculate the total current drawn from the extension lead. [3]
(b) Explain why this is a hazard. [2]

9. A washing machine has a metal case connected to the earth wire. A fault causes the live wire to touch the case.

(a) Describe how the earth wire and the fuse make the washing machine safe. [3]
(b) The earth wire has become disconnected. Explain what would happen if a person touched the case. [2]

10. A hair dryer has a plastic casing and a cable with only two wires.

(a) Name the two wires. [1]
(b) Explain why the hair dryer is safe to use without an earth wire. [2]
(c) State what the fuse protects in this appliance. [1]

11. The appliances on a kitchen circuit have a total power of 5.5 kW when all are on.

(a) Calculate the total current when all the appliances are on. [2]
(b) Trip switch settings of 16 A, 32 A and 45 A are available. Choose the most suitable setting and explain your choice. [2]
(c) Explain how the trip switch protects the circuit if a fault causes a much larger current. [2]

12. This question is about overheating cables.

(a) Explain why a cable carrying too large a current is a fire hazard. [2]
(b) Suggest why an extension cable on a reel should be fully unwound before it is used for a heater. [2]


Answers

1. The earth wire [1]. [1]

2. Electric shock (from touching the exposed live wire) [1]; fire (from a short circuit or sparking) [1]. [2]

3. Water conducts electricity, so current can flow through the water and a person (to earth), causing a shock [1]. [1]

4. A fuse wire melts and must be replaced; a trip switch opens automatically and can be reset [1]. [1]

5. The maximum current that can flow through it without it melting (it melts if this current is exceeded) [1]. [1]

6. (a) Opening the switch breaks the circuit, so there is no current in the lamp [1].
(b) The lamp is still connected to the live wire, so it is at a high p.d. even when switched off [1]; anyone touching the lamp fitting (for example when changing the bulb) could get an electric shock [1]. [3]

7. (a) I = P / V = 800 ÷ 230 [1] = 3.5 A (3.48 A) [1].
(b) 5 A [1]; it is the smallest rating above the normal current (3 A would melt in normal use) [1].
(c) A fault current larger than normal but below 13 A would not melt the fuse [1], so the cable or toaster could overheat and cause a fire (or the toaster is not protected) [1]. [6]

8. (a) Total power = 2000 + 1200 + 150 = 3350 W [1]; I = 3350 ÷ 230 [1] = 14.6 A [1].
(b) 14.6 A is more than the 13 A the lead is designed for (it is overloaded) [1]; the lead’s cable overheats, which could melt the insulation and cause a fire [1]. [5]

Common mistake: calculating the current for each appliance and then choosing the largest. In parallel, the currents add.

9. (a) A large current flows from the live wire through the case and the earth wire to the ground [1]. This current is larger than the fuse rating, so the fuse melts [1], disconnecting the live supply so the case is no longer live [1].
(b) The case would remain at the high mains p.d. with no current and the fuse would not melt [1]; current would flow through the person to earth, giving an electric shock [1]. [5]

10. (a) Live and neutral [1].
(b) The outer casing is made of a non-conducting material (it is double-insulated) [1], so even if a wire inside comes loose the casing cannot become live [1].
(c) The circuit and the cabling [1]. [4]

11. (a) I = P / V = 5500 ÷ 230 [1] = 23.9 A [1].
(b) 32 A [1]; it is the lowest setting above the normal current; 16 A would trip in normal use and 45 A gives less protection [1].
(c) When the current exceeds the setting, the trip switch opens automatically [1], disconnecting the live supply; it can be reset once the fault is fixed [1]. [6]

12. (a) A large current heats the cable [1]; the insulation can melt or burn, causing a fire (and exposing the wires) [1].
(b) A cable wound on a reel cannot transfer thermal energy to the surroundings easily [1], so with the large current a heater draws it gets much hotter and could overheat [1]. [4]

Common mistake: saying a fuse “lowers the current”. It does nothing in normal use; it melts only when the current exceeds its rating.


Where marks are usually lost

  • Explaining the switch position as “so it switches off” rather than “so it is disconnected from the live supply”.
  • Choosing a fuse equal to or below the normal current.
  • Forgetting to add the currents of appliances on the same lead.
  • Explaining earthing without the large current and the fuse melting.
  • Saying a double-insulated appliance does not need a fuse.