Skip to content
Marlbridge

Revision Notes

Cambridge O Level Chemistry (5070): Acid–base titrations – Revision Notes

Revision notes for Cambridge O Level Chemistry 5070 section 12.2: titration method, indicators, end-point, concordant results, exam traps and a self-test.

Subject
Chemistry
Level
O LEVELS
Topic
Topic 12 – Experimental techniques and chemical analysis
Updated

Aligned to Cambridge O Level Chemistry (5070), 2026-2028. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge O Level Chemistry.

Syllabus points this page covers

5070

  • 12.2 Acid–base titrations

Found an error? Report a correction.

Need help with this topic? Request a free trial class for O Level Chemistry (5070).

These notes condense section 12.2, Acid–base titrations, of the Cambridge O Level Chemistry 5070 syllabus (2026–2028). Both outcomes are required for every candidate. For full explanations and worked examples, use the acid–base titrations study guide; then try the acid–base titrations practice questions.

The two outcomes in one line each

  1. Describe an acid–base titration using a burette, a volumetric pipette and a suitable indicator.
  2. Describe how to identify the end-point using an indicator: the first permanent colour change.

The method in eight steps

  1. Rinse the volumetric pipette with the alkali; fill to the line with a pipette filler.
  2. Run the 25.0 cm³ of alkali into a conical flask.
  3. Add 2–3 drops of indicator.
  4. Rinse the burette with acid; fill through a funnel; remove the funnel; fill the tip.
  5. Read the burette at eye level, bottom of the meniscus.
  6. Add acid while swirling over a white tile; dropwise near the end-point.
  7. Stop at the first permanent colour change; read the burette.
  8. Rough titration first, then repeat until results are concordant (within 0.10 cm³).

Why each technique point matters

Technique What goes wrong without it
Rinse pipette and burette with the solution they will hold water left inside dilutes the solution
Flask rinsed with distilled water only (no problem: water does not change the moles of alkali added)
Remove the funnel drips from the funnel change the reading
Fill the tip below the tap an air bubble leaving the tip is recorded as liquid added
Eye level, bottom of meniscus parallax error; reading too high or too low
White tile colour change harder to see
Swirl acid and alkali do not mix, so the colour change appears early
Dropwise near the end-point end-point overshot
Few drops of indicator colour change blurred

Indicators

Indicator Acid Alkali End-point (acid added to alkali)
Methyl orange red yellow yellow → orange
Thymolphthalein colourless blue blue → colourless
Universal indicator not used not used gradual change, no sharp end-point

Memory hook: “Methyl orange ends orange.”

Processing results

titre = final reading − initial reading
ignore the rough titre
choose concordant titres (within 0.10 cm³)
mean = sum of concordant titres ÷ number used

Burette readings: two decimal places, ending in 0 or 5, unit cm³.

Titration in salt preparation

To make a soluble salt from an acid and an alkali: titrate with indicator to find the volume, then repeat with the same volumes but no indicator, so the salt is not contaminated. Evaporate and crystallise. Details are in Acids, Bases and Salts.

Key terms

Term Meaning
Titration adding one solution from a burette to a measured volume of another until they react exactly
End-point the point at which the indicator changes colour permanently, showing exact neutralisation
Titre the volume of solution added from the burette to reach the end-point
Rough titration a fast first run to find the approximate end-point
Concordant results titres that agree closely, usually within 0.10 cm³
Volumetric pipette apparatus that delivers one fixed volume precisely
Burette graduated tube with a tap, for adding and measuring variable volumes
Meniscus the curved liquid surface; read at the bottom

Exam traps

  • “Until neutral” scores nothing: name the colours.
  • Methyl orange is yellow in alkali, not orange; orange is the end-point colour.
  • Do not average the rough titre or a result that is not concordant.
  • A conical flask, not a beaker, so it can be swirled.
  • Rinse with the solution, except the conical flask, which is rinsed with distilled water.
  • Two decimal places for every burette reading: 0.00, not 0.
  • A measuring cylinder is not a substitute for the pipette in a titration.

Self-test

  1. Name the apparatus used to measure 25.0 cm³ of alkali into the flask.
  2. Why is a pipette filler used?
  3. State the colour change at the end-point when acid is added from a burette to alkali containing thymolphthalein.
  4. Why is universal indicator not used in titrations?
  5. Why is the burette rinsed with the acid before it is filled?
  6. Why does it not matter if the conical flask is wet with distilled water?
  7. Why is a white tile placed under the flask?
  8. A burette reads 1.20 cm³ at the start and 24.65 cm³ at the end. Calculate the titre.
  9. Titres: rough 25.4 cm³; then 24.60, 24.95, 24.70 cm³. Which are concordant, and what is the mean?
  10. How do you know you have overshot the end-point using methyl orange?
  11. Why is the funnel removed before taking the initial reading?
  12. When a titration is used to make a salt, why is it repeated without indicator?

Answers

  1. Volumetric pipette.
  2. To fill the pipette safely, without sucking solution into the mouth.
  3. Blue to colourless.
  4. It changes colour gradually over a range of pH, so there is no sharp end-point.
  5. So that water left in the burette does not dilute the acid.
  6. Water does not change the amount (moles) of alkali delivered by the pipette.
  7. To make the colour change easier to see.
  8. Titre = 24.65 − 1.20 = 23.45 cm³.
  9. 24.60 and 24.70 cm³ are concordant; mean = (24.60 + 24.70) ÷ 2 = 24.65 cm³. The rough titre and 24.95 cm³ are left out.
  10. The solution turns red instead of orange.
  11. Liquid dripping from the funnel would change the reading, and the funnel can block a clear view of the scale.
  12. So the salt is not contaminated by the indicator.

Related resources

Related articles

Get free revision emails (optional)