Skip to content
Marlbridge

Practice Questions

Cambridge O Level Chemistry (5070): Experimental design – Practice Questions

Original practice questions with mark-scheme answers on Cambridge O Level Chemistry 5070 section 12.1: apparatus, judging methods and solution terms.

Subject
Chemistry
Level
O LEVELS
Topic
Topic 12 – Experimental techniques and chemical analysis
Updated

Aligned to Cambridge O Level Chemistry (5070), 2026-2028. Official specification .

Syllabus page (what it covers and how it is assessed): Cambridge O Level Chemistry.

Syllabus points this page covers

5070

  • 12.1 Experimental design

Found an error? Report a correction.

Need help with this topic? Request a free trial class for O Level Chemistry (5070).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers from your board or school.

These questions cover section 12.1, Experimental design, of the Cambridge O Level Chemistry 5070 syllabus (2026–2028). Learn the content first with the experimental design study guide and the experimental design revision notes.

Section A

1. Name the most suitable apparatus to measure each of the following.

(a) the time taken for a piece of magnesium ribbon to disappear in acid [1]

(b) 25.0 cm³ of sodium carbonate solution, to be placed in a conical flask [1]

(c) the mass of a sample of copper(II) oxide [1]

2. Which apparatus is most suitable for adding hydrochloric acid gradually to an alkali and measuring the volume added?

A: gas syringe

B: burette

C: volumetric pipette

D: 100 cm³ measuring cylinder

[1]

3. Define the term solute. [1]

4. A student writes: “A saturated solution is a solution that cannot dissolve any more solid.” State what is missing from this definition. [1]

5. Sea water is filtered through filter paper.

(a) Name the liquid that passes through the filter paper. [1]

(b) State why this liquid is not pure water. [1]

6. A thermometer has a scale marked every 1 °C. A student records three temperatures: 24 °C, 26.5 °C and 27.3 °C. Rewrite each reading correctly, or state that it is already correct. [3]

Section B

7. A student investigates the rate of reaction between calcium carbonate chips and dilute hydrochloric acid. The flask is placed on a balance and the mass is recorded every 30 seconds.

(a) Explain why the mass of the flask and contents decreases. [1]

(b) A cotton wool plug is placed in the neck of the flask. Explain why. [2]

(c) The student repeats the experiment using magnesium ribbon and dilute hydrochloric acid, which produces hydrogen. Suggest why the mass-loss method is unsuitable for this reaction. [2]

(d) Suggest a better apparatus for following the magnesium reaction. [1]

8. Two methods are suggested for measuring the volume of carbon dioxide produced in a reaction.

Method 1: collect the gas in an upturned measuring cylinder full of water.

Method 2: collect the gas in a gas syringe.

(a) Suggest one disadvantage of Method 1. [2]

(b) Suggest one disadvantage of Method 2. [1]

9. A student measures the temperature rise when two solutions react in a glass beaker. The measured rise is smaller than the value in a data book.

(a) Suggest a reason for the smaller rise. [1]

(b) Suggest two improvements to the apparatus or method. [2]

10. A student must measure 7.0 cm³ of dilute acid. Measuring cylinders of 10 cm³, 25 cm³ and 100 cm³ are available. State which cylinder should be used and explain the choice. [2]

11. A mixture of potassium chloride and charcoal is stirred with water at 20 °C and then filtered. The liquid collected is heated to evaporate the water completely.

(a) Name the solvent in this experiment. [1]

(b) Identify the residue left on the filter paper. [1]

(c) Identify the residue left after evaporation. [1]

(d) The student uses only a small volume of water and some potassium chloride is left undissolved. State the term for the solution formed. [1]

12. The time for a reaction is measured four times: 41 s, 43 s, 58 s and 42 s.

(a) Identify the anomalous result. [1]

(b) Calculate the mean time, leaving out the anomalous result. Give your answer to the nearest second. [2]

(c) State why repeating the measurement does not correct an error caused by a stop-watch that runs slow. [1]

13. A student uses a balance that reads to 0.1 g to find the mass of 0.25 g of zinc powder. Suggest a disadvantage of using this balance and suggest an improvement. [2]

Answers

1. (a) Stop-watch [1]

(b) Volumetric pipette [1]

(c) Balance [1]

[3]

2. B [1]. [1]

Examiner insight: C is the common wrong choice. A volumetric pipette delivers one fixed volume only, so it cannot add acid gradually.

3. A substance that is dissolved in a solvent [1]. [1]

4. The temperature must be specified / it is the maximum concentration of solute at a specified temperature [1]. [1]

5. (a) The filtrate [1]

(b) Dissolved substances (such as salt) pass through the filter paper, so they are still in the filtrate [1].

[2]

6. 24 °C should be 24.0 °C [1]; 26.5 °C is correct [1]; 27.3 °C should be 27.5 °C, as the scale can only be read to the nearest half division, 0.5 °C [1]. [3]

7. (a) Carbon dioxide gas is produced and escapes from the flask [1].

(b) It lets the gas escape [1] but stops acid spray escaping, which would cause an extra, false loss in mass [1].

(c) Hydrogen has a very low mass / is a very light gas [1], so the loss in mass is too small to measure on the balance / to see a pattern [1].

(d) Gas syringe [1].

[6]

8. (a) Carbon dioxide is soluble in water / some carbon dioxide dissolves [1], so the volume measured is too low [1].

(b) The syringe has a limited capacity / the plunger may stick [1].

[3]

9. (a) Energy was lost to the surroundings through the glass [1].

(b) Any two [2]: use a polystyrene cup; add a lid; stir the mixture; read the highest temperature reached.

[3]

10. The 10 cm³ cylinder [1]. The volume is a larger fraction of its scale / it has smaller divisions, so the reading is more precise [1]. [2]

11. (a) Water [1]

(b) Charcoal [1]

(c) Potassium chloride [1]

(d) Saturated solution [1]

[4]

12. (a) 58 s [1]

(b) (41 + 43 + 42) ÷ 3 [1] = 42 s [1]

(c) The error is in the same direction every time / it is a systematic error, so every repeat is affected equally [1].

[4]

13. Disadvantage: 0.25 g cannot be measured precisely because the balance reads only to 0.1 g / the reading would be 0.2 g or 0.3 g [1]. Improvement: use a balance that reads to 0.01 g, or use a larger mass so that the 0.1 g scale division is a smaller fraction of the reading [1]. [2]

Where marks are usually lost

  • Naming a measuring cylinder when a fixed or precisely variable volume is required.
  • Writing “it is more accurate” with no reason.
  • Forgetting that a filtrate may contain dissolved solutes.
  • Leaving the temperature out of the definition of a saturated solution.
  • Including an anomalous result in a mean.
  • Recording readings with the wrong number of decimal places for the scale.

More on this topic