Revision Notes
Cambridge O Level Physics (5054): Electromagnetic effects – Revision Notes
Quick recall for 5054 subtopic 4.5: induction, Lenz's law, generators, fields of currents, relays, loudspeakers, motors and transformers, with a self-test.
- Subject
- Physics
- Level
- O LEVELS
- Topic
- Electricity and magnetism
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Hassan (what this means)
Aligned to Cambridge O Level Physics (5054), 2026-2028. Official specification .
Syllabus page (what it covers and how it is assessed): Cambridge O Level Physics.
Syllabus points this page covers
5054
- 4.5 Electromagnetic effects
Found an error? Report a correction.
Need help with this topic? Request a free trial class for O Level Physics (5054).
Condensed notes for subtopic 4.5 Electromagnetic effects in Cambridge O Level Physics 5054. For full explanations and worked examples, use the Electromagnetic effects study guide; for exam-style questions, use the Electromagnetic effects practice questions.
Induction (4.5.1)
- E.m.f. induced when the field through a coil changes, or a wire cuts field lines.
- No relative movement (or no change) → no e.m.f.
- Bigger e.m.f.: faster change (faster movement, stronger magnet); more turns.
- Reverse the motion or the pole → induced current reverses.
Lenz’s law: the induced current opposes the change producing it.
| Action | Pole induced at the near end of the coil |
|---|---|
| N pole pushed in | N (repels) |
| N pole pulled out | S (attracts) |
| S pole pushed in | S (repels) |
| S pole pulled out | N (attracts) |
a.c. generator (4.5.2)
- Coil rotates in a magnetic field; slip rings and brushes keep contact without twisting wires.
- Rotating-magnet type: fixed coil, no slip rings.
| Coil plane relative to field | E.m.f. |
|---|---|
| Parallel (sides cutting lines fastest) | Maximum |
| Perpendicular (sides moving along lines) | Zero |
One turn: 0 → max → 0 → min → 0. Faster rotation → taller peaks and higher frequency.
Magnetic effect of a current (4.5.3)
| Conductor | Field pattern | Direction rule |
|---|---|---|
| Straight wire | Concentric circles, weaker further out | Right-hand grip: thumb = current, fingers = field |
| Solenoid | Bar-magnet pattern outside; strong, uniform inside | Fingers = current; thumb = N pole |
More current → stronger field. Reverse current → field reverses.
Relay: coil current → soft-iron core magnetised → armature attracted → contacts close (or open) in a second circuit. Small current controls a large or mains current (car starter motor, mains switching).
Loudspeaker: a.c. in a coil in a permanent magnet’s field → force reverses with the current → coil and cone vibrate → sound at the signal frequency.
Force on a conductor (4.5.4)
- Current at right angles to a field → force.
- Reverse current or field → force reverses; reverse both → unchanged.
- Fleming’s left-hand rule: First finger = Field, seCond = Current, thuMb = Motion.
- Parallel wires: same direction currents attract; opposite directions repel.
d.c. motor (4.5.5)
Turning effect increased by:
- more turns
- more current
- stronger field
Split-ring commutator + brushes: reverses the current in the coil every half turn, so the coil keeps turning the same way.
Transformer (4.5.6)
Vp / Vs = Np / Ns
- Primary and secondary coils on a soft-iron core.
- a.c. in primary → changing field in core → alternating e.m.f. induced in secondary.
- Step-up: Ns > Np. Step-down: Ns < Np.
- Does not work on steady d.c.
High-voltage transmission: same power, higher V → lower I → much smaller heating losses in cables (loss = I × p.d. across cable, and that p.d. = I × R).
Key terms
| Term | Meaning |
|---|---|
| Electromagnetic induction | Producing an e.m.f. by changing the magnetic field through a conductor |
| Lenz’s law | The induced current opposes the change producing it |
| Slip rings | Continuous rings connecting a generator coil to the circuit |
| Split-ring commutator | Divided ring that reverses the coil current every half turn in a d.c. motor |
| Solenoid | A long coil of wire |
| Armature (relay) | Iron piece attracted by the relay’s electromagnet, moving the contacts |
| Step-up transformer | Increases the alternating p.d.; more secondary turns |
| Step-down transformer | Decreases the alternating p.d.; fewer secondary turns |
Exam traps
- Motor force: left hand. Grip rule for fields: right hand.
- Slip rings → generator (a.c.); split ring → motor (d.c.).
- Generator e.m.f. is zero when the coil is perpendicular to the field.
- Faster rotation changes both amplitude and frequency.
- Transformers need a.c.
- High-voltage transmission reduces the current, and so the losses, not the power delivered.
- Lenz’s law answers must name the pole and say “opposes”.
Self-test
- A magnet rests inside a coil. Is an e.m.f. induced?
- Give two ways of increasing the e.m.f. induced by moving a magnet into a coil.
- State Lenz’s law.
- An S pole is pushed into a coil. Which pole forms at the near end?
- What is the purpose of slip rings in an a.c. generator?
- At what coil position is the generator e.m.f. zero?
- Describe the magnetic field around a straight current-carrying wire.
- Two parallel wires carry currents in the same direction. Do they attract or repel?
- Name the three factors that increase the turning effect on a motor coil.
- What does the split-ring commutator do?
- A transformer has 600 primary turns on 240 V; the output is 12 V. Find the secondary turns.
- Why are power cables operated at high voltage?
Answers
- No — the field is not changing.
- Move the magnet faster; use a stronger magnet; use more turns (any two).
- The induced current opposes the change producing it.
- An S pole (repelling the approaching S pole).
- They connect the rotating coil to the external circuit without twisting the wires.
- When the plane of the coil is perpendicular to the field.
- Concentric circles centred on the wire, further apart with distance; direction from the right-hand grip rule.
- Attract.
- More turns, larger current, stronger magnetic field.
- Reverses the current in the coil every half turn so it keeps rotating in the same direction.
- Ns = 600 × 12 ÷ 240 = 30 turns.
- For the same power, the current is smaller, so less energy is lost heating the cables.
Written against Cambridge O Level Physics 5054, 2026–2028 series.
Related resources
-
Study guides
Cambridge O Level Physics (5054): Practical electricity
Electrical power, energy, the kilowatt-hour and cost, lighting circuits, fuses, trip switches, earthing and mains wiring for Cambridge O Level Physics 5054.
Physics · Cambridge · O Level
Read guide -
Practice questions
Cambridge O Level Physics (5054): Practical electricity – Practice Questions
Original 5054 questions with full answers on electrical power and energy, kW h and cost, parallel lighting, fuse ratings, trip switches, earthing and wiring.
Physics · Cambridge · O Level
Try questions -
Revision notes
Cambridge O Level Physics (5054): Practical electricity – Revision Notes
Quick recall for 5054 subtopic 4.4: P = IV, E = IVt, kW h and cost, lamps in parallel, hazards, fuses, trip switches, earthing and live-wire switching.
Physics · Cambridge · O Level
Revise topic
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.