Skip to content
Marlbridge

Revision Notes

OCR A Level Chemistry A (H432): Use of apparatus and techniques – Revision Notes

Condensed OCR H432 1.2.2 notes: apparatus uncertainties, heat sources, pH methods, fault-and-effect tables for titrations, purification checks and a self-test.

Subject
Chemistry
Level
A LEVELS
Topic
Module 1: Development of practical skills in chemistry
Updated

Aligned to OCR A Level Chemistry (H432), Version 3.1 (May 2026), for first assessment in 2017. Official specification .

Syllabus page (what it covers and how it is assessed): OCR A Level Chemistry.

Syllabus points this page covers

H432

  • 1.2.2 Use of apparatus and techniques

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Chemistry (H432).

These notes condense 1.2.2 Use of apparatus and techniques from OCR A Level Chemistry A (H432), Version 3.1 (May 2026). Statement 1.2.2 lists twelve groups of apparatus and techniques, (a) to (l), used across the minimum of 12 assessed practicals in the Practical Endorsement. The written papers test the same techniques, usually by asking you to choose apparatus, justify a step or predict the effect of a fault.

The explanations and worked examples are in the 1.2.2 study guide, and the 1.2.2 practice questions test them. Standard methods for every PAG are in the practical endorsement revision notes.

Key terms

Term Meaning
Resolution Smallest change a piece of apparatus can show
Uncertainty Range either side of a reading within which the true value lies
Percentage uncertainty Uncertainty ÷ quantity measured × 100
Mass by difference Weigh container with solid, transfer solid, reweigh container
Titre Volume delivered from the burette: final reading minus initial reading
Concordant titres Titres that agree closely, usually within 0.10 cm³
Standard solution Solution of accurately known concentration, made in a volumetric flask
Calibration Setting an instrument against standards of known value, such as pH buffers
Continuous monitoring Following one property through a single run of a reaction
Initial rate method Measuring rate at the start of each run, for example with a clock reaction

Statement (a): uncertainties to recall

  • Single analogue reading: half the smallest division.
  • Any difference of two readings (titre, mass by difference, temperature change): double the single-reading uncertainty.
Measurement Uncertainty
Burette reading / titre ±0.05 cm³ / ±0.10 cm³
Mass by difference, 2 d.p. balance ±0.01 g
Mass by difference, 3 d.p. balance ±0.001 g
Temperature change, 1 °C thermometer ±1.0 °C
Temperature change, 0.1 °C thermometer ±0.10 °C
Measuring cylinder, 1 cm³ divisions ±0.5 cm³
Pipette, volumetric flask Tolerance printed on the glass

Reducing a percentage uncertainty. Either measure a larger quantity (more solid, longer titre, bigger temperature rise) or use apparatus with finer resolution. Aim the improvement at the measurement with the largest percentage.

Worked reminder

A titre of 12.50 cm³ has 0.10 ÷ 12.50 × 100 = 0.80% uncertainty. Doubling the concentration of the solution in the flask would double the titre to 25.00 cm³ and halve the percentage to 0.40%.

Statements (b) and (c): heating and pH

Heat source Use it when Avoid it when
Water bath Gentle, even warming below 100 °C Mixture must exceed 100 °C
Electric heater (mantle) Flammable mixture must boil (reflux, distillation) Gentle warming of test-tubes
Sand bath Even heating above 100 °C Rapid temperature changes are needed
pH method Precision Key point
pH chart About 1 unit Colour judged by eye
pH meter About 0.01 unit Calibrate with buffers; rinse between samples
Probe on data logger About 0.01 unit Records pH continuously, e.g. a pH curve

Statements (d)(i), (e), (f): faults and their effects

Learn each line as fault → effect on titre → effect on calculated result.

Fault Effect on titre If the titrant concentration is being found
Burette rinsed with water only Too large (titrant diluted) Concentration too low
Pipette rinsed with water only Too small (less analyte delivered) Concentration too high
Conical flask rinsed with analyte Too large (extra analyte) Concentration too low
Air bubble in burette tip escapes Too large Concentration too low
Funnel left in burette drips in Level rises, so recorded titre too small Concentration too high
End point overshot Too large Concentration too low

Standard solution checks (e). Rinse beaker, rod and funnel into the flask; make up to the mark with the bottom of the meniscus on the line at eye level; stopper and invert. Lost washings make the solution too dilute.

Indicator (f). Strong acid–weak base: methyl orange. Weak acid–strong base: phenolphthalein. Weak–weak: no sharp end point.

Statements (d)(ii)–(iv), (g)–(i): preparation and purification

  • Reflux: condenser vertical, open top, water in at the bottom; never heat a closed system.
  • Distillation: thermometer bulb at the side arm; collect the fraction at the expected boiling point.
  • Retort stand and clamps: clamp the flask neck and the condenser.
  • Qualitative tests (d)(iii): warm with a water bath, add reagents dropwise, record colours and precipitates exactly.
  • Fluted filter paper: fast gravity filtration, keep the filtrate.
  • Reduced pressure (Büchner): keep the solid; drier crystals.
  • Separating funnel: denser layer at the bottom; identify the aqueous layer by adding water; vent pressure often.
  • Recrystallisation: minimum hot solvent, cool, filter, wash with ice-cold solvent, dry.
  • Melting point: impure or damp solid melts lower and over a wider range.
  • Chromatography: pencil baseline above the solvent; mark the front at once; Rf = spot distance ÷ solvent front distance.

Statements (j)–(l): cells, safety and rates

  • Cell: two half-cells, salt bridge (ions carry charge), high-resistance voltmeter (no current drawn), clean electrodes.
  • Hazards (k): corrosive, irritant, flammable, toxic. Name the hazard, then a matching control.
  • Rates (l): at least two methods. Initial rate, e.g. clock reaction (rate ∝ 1/t). Continuous monitoring: gas volume, mass loss or colour against time in one run.

Exam traps

  • A titre uncertainty is ±0.10 cm³, not ±0.05 cm³.
  • “Inaccurate” earns nothing: give the direction of the error.
  • Mass loss in an open flask: acid spray exaggerates the loss; use cotton wool.
  • A water bath cannot reach 120 °C.
  • A wire is not a salt bridge.
  • Fluted paper is for filtrates; Büchner filtration is for solids.

Quick self-test

  1. What is the uncertainty of a temperature change measured with a thermometer graduated every 1 °C?
  2. Give the percentage uncertainty in a titre of 20.00 cm³.
  3. 0.150 g is weighed by difference on a three-decimal-place balance. What is the percentage uncertainty?
  4. Which heat source would you use to boil a flammable organic mixture under reflux?
  5. Why must a pH meter be calibrated before use?
  6. A pipette is rinsed with distilled water but not with the solution. What happens to the titre?
  7. The burette is not rinsed with the titrant. Is the calculated titrant concentration too high or too low?
  8. Why is the stoppered volumetric flask inverted several times?
  9. When would you choose fluted filter paper?
  10. How can you tell which layer in a separating funnel is aqueous?
  11. Why is a high-resistance voltmeter used?
  12. Name the two types of method for measuring rates required by 1.2.2(l).

Answers

  1. ±1.0 °C (two readings of ±0.5 °C).
  2. 0.10 ÷ 20.00 × 100 = 0.50%.
  3. 0.001 ÷ 0.150 × 100 = 0.67%.
  4. An electric heater, such as a heating mantle.
  5. So its readings match buffers of known pH; otherwise every reading carries a systematic error.
  6. The aliquot is diluted, fewer moles are delivered, and the titre is too small.
  7. Too low: the titrant is diluted, so the titre is too large.
  8. To mix the solution so every aliquot has the same concentration.
  9. When you need the filtrate quickly, for example removing insoluble impurities from a hot solution.
  10. Add a few drops of water and see which layer increases.
  11. It draws almost no current, so the reading is the cell potential.
  12. An initial rate method (such as a clock reaction) and a continuous monitoring method.

Official syllabus

OCR A Level Chemistry A (H432) specification, Version 3.1 (May 2026), for first assessment in 2017, section 1.2.2 Use of apparatus and techniques, statements (a) to (l). Published by OCR.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.