OxfordAQA A-Level Physics (9630): Energy transfer by conduction – Practice Questions

Original practice questions with mark-scheme answers on OxfordAQA 9630 section 3.11.2: conduction rates, lagged rods, U-values and building heat loss.

Subject
Physics
Level
A LEVEL
Topic
Section 3.11 – Thermal physics
Updated

Aligned to OxfordAQA A Level Physics (9630), International AS and A-level. Official specification .

Syllabus page (what it covers and how it is assessed): OxfordAQA A Level Physics.

Syllabus points this page covers

9630 (A Level)

  • 3.11.2 Energy transfer by conduction

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (9630).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers from your board or school.

These questions cover section 3.11.2, Energy transfer by conduction, of OxfordAQA International AS and A-level Physics (9630), which is International A-level only content. Learn the content first with the conduction study guide and the conduction revision notes. Assume steady-state conditions unless a question says otherwise. Take the specific latent heat of fusion of ice as 3.34 × 10⁵ J kg⁻¹.

Questions

Section A: short questions

1. Write down the equation for the rate of energy transfer by conduction through a slab, and state the unit of thermal conductivity. [2]

2. Use the relationship U = k/L to show that the unit of U is W m⁻² K⁻¹. [2]

3. A glass pane measures 0.80 m by 1.2 m and is 6.0 mm thick. The thermal conductivity of the glass is 0.96 W m⁻¹ K⁻¹ and its two faces differ in temperature by 0.80 K. Calculate the rate of energy transfer through the pane. [2]

4. Two lagged rods are made of the same metal and have the same temperature difference between their ends. Rod Y is twice as long as rod X and has twice its diameter. Calculate the ratio rate through Y : rate through X. [2]

5. Explain why metals are much better thermal conductors than non-metals. [2]

6. Explain why a jacket filled with loose fibres keeps a person warm, even though the fibres themselves are not especially poor conductors. [2]

Section B: structured questions

7. An aluminium bar of length 0.30 m and cross-sectional area 4.0 cm² is well lagged. One end is held at 95 °C and the other at 15 °C. The thermal conductivity of aluminium is 210 W m⁻¹ K⁻¹.

(a) Calculate the rate of energy transfer along the bar. [2]

(b) Calculate the temperature at a point 0.10 m from the hot end. [1]

(c) Explain why the answer to (b) would be wrong if the bar were not lagged. [2]

8. A room is kept at 18 K above the outside temperature. Its outer surfaces are a wall of area 30 m² (U = 0.35 W m⁻² K⁻¹), a window of area 6.0 m² (U = 2.0 W m⁻² K⁻¹) and a ceiling of area 20 m² (U = 0.25 W m⁻² K⁻¹).

(a) Calculate the total rate of energy loss through these surfaces. [3]

(b) Calculate the energy lost in 8.0 hours, in joules and in kWh. [2]

(c) The owner can either halve the U-value of the window or halve the U-value of the wall. Determine which gives the larger reduction in the rate of loss. [2]

9. A builder fills a wall cavity with foam of thermal conductivity 0.030 W m⁻¹ K⁻¹.

(a) Calculate the minimum thickness of foam needed for a U-value no greater than 0.25 W m⁻² K⁻¹. [2]

(b) The builder uses 80 mm of foam instead. Calculate the rate of energy loss through 40 m² of this layer when the temperature difference is 20 K. [2]

10. A student measures the thermal conductivity of a sheet of plastic. The sheet, of area 0.040 m² and thickness 5.0 ± 0.1 mm, is clamped between a heater plate and a cold plate. In the steady state the heater supplies 12.0 W and thermometers in the two plates read 34.5 °C and 22.5 °C, each with an uncertainty of ±0.2 °C.

(a) Calculate the thermal conductivity of the plastic. [2]

(b) Calculate the percentage uncertainty in the thickness and in the temperature difference, and hence the absolute uncertainty in k. Ignore uncertainties in the area and power. [3]

(c) Some energy escapes from the edges of the heater plate. State and explain the effect on the calculated value of k. [1]

11. A polystyrene cool box has a total surface area of 0.60 m² and walls 2.5 cm thick. The thermal conductivity of polystyrene is 0.033 W m⁻¹ K⁻¹. The box contains melting ice at 0 °C and the air outside is at 30 °C.

(a) Calculate the rate of energy transfer into the box. [2]

(b) Calculate the mass of ice that melts in 6.0 hours. [2]

(c) Suggest two changes to the box that would reduce this mass, and explain each using the conduction equation. [2]

12. A hot-water tank has a surface area of 2.4 m² and is kept 60 K above its surroundings. Two lagging jackets are available: jacket A is 50 mm thick with k = 0.040 W m⁻¹ K⁻¹; jacket B is 80 mm thick with k = 0.050 W m⁻¹ K⁻¹.

(a) Calculate the U-value of each jacket and state which is the better insulator. [2]

(b) Calculate the energy lost in one day through the better jacket, in kWh. [2]

Answers

1. Rate of energy transfer = kAΔθ/L [1]; unit of k is W m⁻¹ K⁻¹ [1] [2]

Examiner insight: Define the symbols if the question does not; A is the area at right angles to the flow and L the thickness.

2. k has unit W m⁻¹ K⁻¹ and L has unit m [1]; W m⁻¹ K⁻¹ ÷ m = W m⁻² K⁻¹ [1] [2]

Examiner insight: Show the division explicitly; quoting the answer alone does not “show” anything.

3. A = 0.80 × 1.2 = 0.96 m² and L = 6.0 × 10⁻³ m [1]; rate = 0.96 × 0.96 × 0.80 / 6.0 × 10⁻³ = 1.2 × 10² W [1] [2]

Examiner insight: A small temperature difference across glass still gives a large rate because the pane is so thin.

4. Area of Y is 4 times that of X; length is 2 times [1]; rate ∝ A/L, so ratio = 4/2 = 2 : 1 [1] [2]

Examiner insight: Doubling the diameter multiplies the area by four, not two.

5. Metals contain free (delocalised) electrons that move through the lattice [1] and carry energy quickly from hot to cold regions, in addition to energy passed on by lattice vibrations [1] [2]

Examiner insight: Lattice vibrations alone occur in all solids, so they cannot explain the difference.

6. The fibres trap a large volume of still air, which has a very low thermal conductivity [1]; trapped air cannot circulate, so energy is not carried away by convection [1] [2]

Examiner insight: Credit needs both ideas: air conducts poorly and the fibres stop it moving.

7. (a) A = 4.0 × 10⁻⁴ m² and Δθ = 80 K [1]; rate = 210 × 4.0 × 10⁻⁴ × 80 / 0.30 = 22 W (22.4 W) [1]

(b) The temperature falls by 80 K over 0.30 m, so by 26.7 K over 0.10 m: 95 − 26.7 = 68 °C [1]

(c) Energy would escape through the sides of the bar [1], so the rate would fall along the bar and the temperature gradient would not be uniform; the temperature profile would not be linear [1] [5]

Examiner insight: In (c) state the consequence for the gradient; “energy is lost” alone earns only the first mark.

8. (a) Wall 0.35 × 30 × 18 = 189 W; window 2.0 × 6.0 × 18 = 216 W [1]; ceiling 0.25 × 20 × 18 = 90 W [1]; total = 495 W, about 5.0 × 10² W [1]

(b) Energy = 495 × 8.0 × 3600 = 1.4 × 10⁷ J [1]; 0.495 kW × 8.0 h = 4.0 kWh [1]

(c) Halving the window U saves 216/2 = 108 W; halving the wall U saves 189/2 = 94.5 W [1]; the window change gives the larger reduction [1] [7]

Examiner insight: Compare the UA (or rate) of each surface; the one with the larger product gives the bigger saving for the same fractional change.

9. (a) L = k/U [1] = 0.030/0.25 = 0.12 m (120 mm) [1]

(b) U = 0.030/0.080 = 0.375 W m⁻² K⁻¹ [1]; rate = 0.375 × 40 × 20 = 300 W [1] [4]

Examiner insight: A thinner layer than required gives a larger U-value; checking that 0.375 exceeds 0.25 confirms the answer makes sense.

10. (a) Δθ = 12.0 K and L = 5.0 × 10⁻³ m [1]; k = 12.0 × 5.0 × 10⁻³ / (0.040 × 12.0) = 0.125 W m⁻¹ K⁻¹ [1]

(b) Thickness: 0.1/5.0 = 2.0% [1]; temperature difference uncertainty = 0.2 + 0.2 = 0.4 K, so 0.4/12.0 = 3.3% [1]; total 5.3%, so k = 0.125 ± 0.007 W m⁻¹ K⁻¹ [1]

(c) Less than 12.0 W passes through the sheet, so the true rate is smaller than the value used and the calculated k is too large [1] [6]

Examiner insight: A difference of two readings takes the sum of their absolute uncertainties.

11. (a) L = 0.025 m [1]; rate = 0.033 × 0.60 × 30 / 0.025 = 24 W (23.8 W) [1]

(b) Energy = 23.8 × 6.0 × 3600 = 5.1 × 10⁵ J [1]; mass = 5.13 × 10⁵ / 3.34 × 10⁵ = 1.5 kg [1]

(c) Any two, each with its reason: thicker walls, because the rate is inversely proportional to L [1]; a material of lower k, because the rate is proportional to k; or a smaller surface area for the same contents, because the rate is proportional to A [1] [6]

Examiner insight: Each suggestion must name the factor in the equation that it changes.

12. (a) U(A) = 0.040/0.050 = 0.80 W m⁻² K⁻¹; U(B) = 0.050/0.080 = 0.625 W m⁻² K⁻¹ [1]; B is the better insulator because it has the lower U-value [1]

(b) Rate = 0.625 × 2.4 × 60 = 90 W [1]; energy = 0.090 kW × 24 h = 2.2 kWh [1] [4]

Examiner insight: B is made of a better conductor than A but is thick enough to insulate better, which is why U, not k, decides.

Where marks are usually lost

  • Leaving thicknesses in mm or areas in cm².
  • Doubling the area when the diameter doubles.
  • Adding U-values instead of the products UA.
  • Giving a rate when the question asks for energy.
  • Stating that a material with a high U-value is a good insulator.
  • Suggesting improvements without linking them to k, A, Δθ or L.