OxfordAQA A-Level Physics (9630): Energy transfer by conduction – Revision Notes
Revision notes for OxfordAQA 9630 section 3.11.2: conduction equation, k and U units, parallel-surface heat loss, exam traps and a 12-question self-test.
- Subject
- Physics
- Level
- A LEVEL
- Topic
- Section 3.11 – Thermal physics
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Iftikhar Azeemi (what this means)
Aligned to OxfordAQA A Level Physics (9630), International AS and A-level. Official specification .
Syllabus page (what it covers and how it is assessed): OxfordAQA A Level Physics.
Syllabus points this page covers
9630 (A Level)
- 3.11.2 Energy transfer by conduction
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Physics (9630).
These notes condense section 3.11.2, Energy transfer by conduction, of OxfordAQA International AS and A-level Physics (9630). It sits in Section 3.11 Thermal physics, which is International A-level only. For full explanations and worked examples, read the conduction study guide, then test yourself with the conduction practice questions. Internal energy, the first law and specific heat capacity are summarised in the first law of thermodynamics, heating and conduction revision notes.
The two equations
Rate of energy transfer by conduction = kAΔθ/L
Rate of energy transfer = UAΔθ, where U = k/L
| Symbol | Quantity | Unit | Watch for |
|---|---|---|---|
| Rate | energy transferred per second | W | multiply by time for energy |
| k | thermal conductivity of the material | W m⁻¹ K⁻¹ | material property only |
| A | area at right angles to the flow | m² | cm² × 10⁻⁴; mm² × 10⁻⁶ |
| Δθ | temperature difference across the layer | K or °C | a difference, so either unit |
| L | thickness of slab or length of rod | m | mm × 10⁻³ |
| U | U-value of one layer | W m⁻² K⁻¹ | low U = good insulator |
Rearranged forms: k = (rate × L)/(AΔθ); L = kAΔθ/rate; Δθ = (rate × L)/(kA); L = k/U.
Condensed recall
- Conduction transfers energy through a material without bulk movement of the material. Vibrating particles pass energy to neighbours; in metals free electrons carry energy too, so metals conduct far better.
- Gases conduct poorly because their particles are widely spaced. Insulators work by trapping still air so that convection cannot occur.
- The equation holds in the steady state, when temperatures no longer change. The same rate then passes every cross-section.
- In a lagged rod or uniform slab in the steady state, temperature falls linearly from hot to cold. Δθ/L is the temperature gradient.
- An unlagged rod loses energy from its sides, so the rate falls along the rod and the profile curves.
- k belongs to a material; U belongs to a layer of a given thickness. Doubling the thickness halves U.
- Parallel surfaces only: walls, windows, roof and door at the same Δθ. Total rate = (U₁A₁ + U₂A₂ + …)Δθ. Layers in series are not required.
- The surface with the largest UA contributes most to the total loss and is the best one to improve.
Key terms
| Term | Meaning |
|---|---|
| Conduction | Energy transfer through a material from hotter to colder regions without bulk movement |
| Thermal conductivity, k | Rate of energy transfer per unit area per unit temperature gradient; unit W m⁻¹ K⁻¹ |
| Temperature gradient | Temperature difference divided by thickness, Δθ/L; unit K m⁻¹ |
| Steady state | Condition in which the temperature at every point stays constant with time |
| U-value | Rate of energy transfer per unit area per kelvin difference for one layer; U = k/L |
| Lagging | Insulation round the sides of a rod or pipe that stops energy escaping sideways |
| Parallel surfaces | Separate surfaces sharing the same inside and outside temperatures, whose losses add |
Proportional reasoning
| Change (all else fixed) | Effect on rate |
|---|---|
| Double the area | × 2 |
| Double the thickness | × 1/2 |
| Double the diameter of a rod | × 4 |
| Double the temperature difference | × 2 |
| Material with three times the k | × 3 |
| Double length and double diameter of a rod | × 4/2 = × 2 |
Exam traps
- Diameter used as radius, or area left in cm².
- Thickness left in mm. A 6.0 mm pane has L = 6.0 × 10⁻³ m.
- k and U confused. Check the unit before substituting.
- “High U-value is a good insulator”: wrong, it is a poor one.
- A rate in W given when the question asked for energy in J or kWh.
- U-values added directly instead of the products UA.
- Assuming a linear temperature profile for an unlagged rod.
- Converting a temperature difference by adding 273. A difference of 15 °C is 15 K.
Quick self-test
- State what is meant by thermal conductivity.
- Derive the unit of k from the conduction equation.
- A slab of area 10 m² and thickness 0.20 m has k = 0.80 W m⁻¹ K⁻¹ and a temperature difference of 12 K. Find the rate of energy transfer.
- Find the U-value of a 0.15 m layer of material with k = 0.045 W m⁻¹ K⁻¹.
- A wall of area 25 m² has U = 0.40 W m⁻² K⁻¹. Find the rate of loss when Δθ = 15 K.
- A lagged rod is replaced by one of the same material with twice the length and three times the cross-sectional area. Δθ is unchanged. By what factor does the rate change?
- A window of area 4.0 m² (U = 2.5 W m⁻² K⁻¹) and a wall of area 20 m² (U = 0.50 W m⁻² K⁻¹) share a temperature difference of 10 K. Find the total rate of loss.
- How much energy passes in 1.0 hour at a steady 150 W?
- Explain why the temperature falls linearly along a lagged rod in the steady state.
- Material P has U = 0.20 W m⁻² K⁻¹ and material Q has U = 0.50 W m⁻² K⁻¹ for the same thickness. Which is the better insulator?
- What thickness of foam with k = 0.030 W m⁻¹ K⁻¹ gives U = 0.20 W m⁻² K⁻¹?
- Explain why fibreglass insulation is a poor conductor even though glass itself conducts better.
Answers
- The rate of energy transfer by conduction per unit area per unit temperature gradient through a material.
- k = rate × L/(AΔθ), so unit = W × m/(m² × K) = W m⁻¹ K⁻¹.
- Rate = 0.80 × 10 × 12/0.20 = 480 W.
- U = 0.045/0.15 = 0.30 W m⁻² K⁻¹.
- Rate = 0.40 × 25 × 15 = 150 W.
- Rate ∝ A/L = 3/2, so it rises by a factor of 1.5.
- Window: 2.5 × 4.0 × 10 = 100 W; wall: 0.50 × 20 × 10 = 100 W; total 200 W.
- Energy = 150 × 3600 = 5.4 × 10⁵ J.
- No energy leaves through the sides and no point is gaining energy, so the same rate passes every cross-section; with constant k and A, the temperature gradient must be the same everywhere.
- P, because a lower U-value means a smaller rate of loss per square metre per kelvin.
- L = k/U = 0.030/0.20 = 0.15 m.
- Most of its volume is still air trapped between the fibres. Air has a very low conductivity, and the fibres stop it circulating, so convection cannot carry energy across.
Official syllabus
OxfordAQA International AS and A-level Physics (9630), section 3.11.2 Energy transfer by conduction, published by OxfordAQA.
Related resources
-
Study guides
OxfordAQA A-Level Physics (9630): Energy transfer by heating and doing work
Study guide to OxfordAQA 9630 section 3.11.1: internal energy, the first law, change of state, multi-stage, mixing and flow problems, and Required practical 8.
Physics · OxfordAQA · A Level
Read guide -
Practice questions
OxfordAQA A-Level Physics (9630): Energy transfer by heating and doing work – Practice Questions
Original practice questions with mark-scheme answers on internal energy, the first law, mcΔθ, ml, mixing, flow and Required practical 8 for OxfordAQA 9630.
Physics · OxfordAQA · A Level
Try questions -
Revision notes
OxfordAQA A-Level Physics (9630): Energy transfer by heating and doing work – Revision Notes
Revision notes for OxfordAQA 9630 section 3.11.1: internal energy, ΔU = Q + W, change of state, mcΔθ, ml, flow and Required practical 8, with a self-test.
Physics · OxfordAQA · A Level
Revise topic
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.