Original practice questions with mark-scheme answers on transformer action, turns ratio, efficiency, losses, line losses and Required practical 7 for 9630.

Subject
Physics
Level
A LEVEL
Topic
Section 3.10 – Magnetic fields
Updated

Aligned to OxfordAQA A Level Physics (9630), International AS and A-level. Official specification .

Syllabus page (what it covers and how it is assessed): OxfordAQA A Level Physics.

Syllabus points this page covers

9630 (A Level)

  • 3.10.6 The operation of a transformer

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (9630).

These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs – examination boards hold copyright in their own papers. Use these alongside the official past papers from your board or school.

These questions cover section 3.10.6, The operation of a transformer, of OxfordAQA International AS and A-level Physics (9630), including Required practical 7. It is International A-level content. Section A has short questions; Section B has longer, structured questions. If a point is unfamiliar, read the transformer study guide or the transformer revision notes first.

All voltages and currents are rms values. All data are invented for practice.

Questions

Section A

1. Explain why a transformer gives no output when its primary is connected to a steady dc supply. [2]

2. An ideal step-up transformer has a turns ratio Np : Ns of 1 : 20. The primary is connected to 12 V and the secondary delivers 0.50 A. What is the primary current?

A: 0.025 A

B: 0.50 A

C: 10 A

D: 20 A

[1]

3. A transformer has 2000 turns on its primary, which is connected to 230 V. Calculate the number of secondary turns needed for an output of 11.5 V. [2]

4. A transformer takes 0.30 A from a 230 V supply and delivers 2.6 A at 24 V.

(a) Calculate its efficiency. [2]

(b) Calculate the power wasted. [1]

5. Explain why transformer cores are laminated. [2]

6. Explain why transformer cores are made of soft iron. [2]

Section B

7. Explain how a transformer produces an alternating output voltage from an alternating input voltage. [4]

8. An ideal transformer at a substation steps 11 kV down to 230 V. The secondary current is 150 A.

(a) Calculate the turns ratio Np : Ns. [1]

(b) Calculate the power delivered. [1]

(c) Calculate the primary current. [2]

9. A power of 120 kW is transmitted through cables with a total resistance of 0.80 Ω.

(a) Calculate the current, the power lost and the p.d. lost in the cables when the power is sent at 6.0 kV. [3]

(b) Repeat the calculation for 600 V. [1]

(c) Use your answers to explain why power is transmitted at high voltage. [2]

10. A transformer is 88% efficient. It delivers 150 W at 12 V from a 230 V supply.

(a) Calculate the input power. [1]

(b) Calculate the primary current. [1]

(c) Calculate the secondary current. [1]

11. In Required practical 7, a student keeps the primary p.d. at 12.0 V and changes the load on the secondary.

Ip / A Vs / V Is / A
0.15 5.8 0.29
0.52 5.6 1.02
0.95 5.3 1.80

(a) Calculate the efficiency for each row. [3]

(b) Describe and explain the trend. [2]

(c) State one safety precaution and one control variable for this investigation. [2]

12. Electrical power passes through a step-up transformer of efficiency 96%, a transmission line that wastes 3% of the power entering it, and a step-down transformer of efficiency 98%. Calculate the percentage of the original power that reaches the consumers. [2]

Answers

1. A steady current produces a steady flux in the core [1]; the flux linkage of the secondary does not change, so no emf is induced (Faraday’s law) [1]. [2]

2. C [1]. Vs = 240 V, so power = 240 × 0.50 = 120 W and Ip = 120/12 = 10 A. [1]

3. Ns = Np × Vs/Vp = 2000 × 11.5/230 [1] = 100 turns [1]. [2]

4. (a) Input = 230 × 0.30 = 69.0 W; output = 24 × 2.6 = 62.4 W [1]; efficiency = 62.4/69.0 = 0.90 (90%) [1]. [2]

(b) 69.0 − 62.4 = 6.6 W [1]. [1]

5. The changing flux induces eddy currents in the core, which heat it and waste energy [1]; thin sheets insulated from each other break up the current paths, so the eddy currents and the heating are reduced [1]. [2]

6. The core is magnetised and demagnetised every cycle, which wastes energy (hysteresis) [1]; soft iron is easily magnetised and demagnetised, so this loss is small [1]. [2]

7. The alternating current in the primary [1] produces an alternating magnetic flux in the iron core [1]. The core carries this flux through the secondary, so the flux linkage of the secondary changes continuously [1]. By Faraday’s law an alternating emf is induced in the secondary, at the same frequency [1]. [4]

8. (a) Np : Ns = 11 000 : 230 = 48 : 1 (47.8 : 1) [1]. [1]

(b) P = 230 × 150 = 3.45 × 10⁴ W (34.5 kW) [1]. [1]

(c) IpVp = IsVs [1]; Ip = 34 500 / 11 000 = 3.1 A [1]. [2]

9. (a) I = 120 000/6000 = 20 A [1]; loss = 20² × 0.80 = 320 W [1]; p.d. lost = 20 × 0.80 = 16 V [1]. [3]

(b) I = 200 A; loss = 32 kW; p.d. lost = 160 V [1]. [1]

(c) At the higher voltage the current is ten times smaller [1], so the power lost (∝ I²) is a hundred times smaller: 0.27% of the power instead of 27%, and the voltage drop is also much smaller [1]. [2]

10. (a) 150/0.88 = 170 W [1]. [1]

(b) 170.5/230 = 0.74 A [1]. [1]

(c) 150/12 = 12.5 A [1]. [1]

11. (a) Row 1: 5.8 × 0.29 / (12.0 × 0.15) = 1.68/1.80 = 93% [1]. Row 2: 5.71/6.24 = 92% [1]. Row 3: 9.54/11.4 = 84% [1]. [3]

(b) Efficiency falls as the load current rises [1]; the heating of the coils is proportional to I², so a larger fraction of the input power is wasted at high current [1]. [2]

(c) Safety: use a low-voltage ac supply and never connect the transformer to the mains (or switch off between readings to avoid overheated coils) [1]. Control: keep the primary voltage, the supply frequency or the transformer (turns and core) the same [1]. [2]

12. Fraction delivered = 0.96 × 0.97 × 0.98 [1] = 0.913, so 91% [1]. [2]

Where marks are usually lost

  • Inverting the turns ratio.
  • Calculating efficiency from voltages without the currents.
  • Writing “heat loss” without naming the cause.
  • Saying laminations stop eddy currents completely.
  • Using the transmission voltage instead of the line current to find the power lost.
  • Adding percentage losses through a chain instead of multiplying efficiencies.

More on this topic

Official syllabus

OxfordAQA International AS and A-level Physics (9630), section 3.10.6 The operation of a transformer and Required practical 7, published by OxfordAQA. Check the board’s website for the current version of the specification.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.