Skip to content
Marlbridge

Revision Notes

OxfordAQA A-Level Physics (9630): The operation of a transformer – Revision Notes

Revision notes for OxfordAQA 9630 section 3.10.6: transformer action, turns ratio, efficiency, losses, line losses and Required practical 7, with a self-test.

Subject
Physics
Level
A LEVEL
Topic
Section 3.10 – Magnetic fields
Updated

Aligned to OxfordAQA A Level Physics (9630), International AS and A-level. Official specification .

Syllabus page (what it covers and how it is assessed): OxfordAQA A Level Physics.

Syllabus points this page covers

9630 (A Level)

  • 3.10.6 The operation of a transformer

Found an error? Report a correction.

Need help with this topic? Request a free trial class for A Level Physics (9630).

These notes condense section 3.10.6, The operation of a transformer, of OxfordAQA International AS and A-level Physics (9630), in Section 3.10 Magnetic fields (International A-level only), including Required practical 7. Full explanations and worked examples are in the transformer study guide; test yourself with the transformer practice questions. Rms values are summarised in the alternating currents revision notes.

Equations

Equation Use Notes
Ns/Np = Vs/Vp Turns and voltages Ideal transformer
IpVp = IsVs Ideal transformer currents So Is/Ip = Np/Ns
Efficiency = IsVs/IpVp Real transformer Fraction; × 100 for %
I = P/V Transmission line current P is the power sent
Power lost = I²R Line heating R is the line resistance
P.d. lost = IR Voltage drop along the line Not the supply voltage

Key terms

Term What to write
Primary coil Coil connected to the ac supply
Secondary coil Coil connected to the load, in which the emf is induced
Step-up transformer More secondary turns than primary turns; Vs > Vp
Step-down transformer Fewer secondary turns than primary turns; Vs < Vp
Ideal transformer No energy losses: power in equals power out
Efficiency Output power divided by input power
Laminated core Core made of thin insulated sheets, to reduce eddy currents

How it works, in four steps

  1. Alternating current in the primary.
  2. Alternating flux in the soft-iron core, which links the secondary.
  3. Changing flux linkage in the secondary.
  4. Alternating emf induced in the secondary (Faraday’s law), same frequency.

DC gives a steady flux: no change of flux linkage, no output.

Causes of inefficiency

Cause Remedy
Coil resistance (I²R heating) Thick copper wire
Eddy currents in the core Laminated core, insulated layers
Hysteresis (repeated magnetising and demagnetising) Soft iron core
Flux leakage Closed core; coils wound close together

Coil heating grows with load current squared. Eddy currents and hysteresis arise from the changing flux and occur even with no load.

High-voltage transmission

  • For a fixed power, raising V by n divides I by n.
  • Power lost I²R falls by n²; p.d. lost IR falls by n.
  • Step-up at the power station, step-down near the user. Transformers need ac.
  • Overall efficiency of a chain = product of the separate efficiencies.

Method box: line-loss calculation

  1. Line current: I = P/V, using the power sent and the transmission voltage.
  2. Power lost: I²R, with R the total resistance of both cables.
  3. Percentage lost: I²R ÷ P × 100.
  4. P.d. lost: IR; the voltage reaching the user is V − IR.
  5. Never put the transmission voltage into V²/R with the line resistance: that p.d. is not across the line.

Required practical 7

  • Low-voltage ac supply only, never the mains.
  • AC ammeter and voltmeter on each coil; variable resistor as load.
  • Calculate IsVs/IpVp for each load.
  • Independent: load current (or turns, or core). Controlled: supply voltage, frequency, transformer.
  • Efficiency usually falls at high load current, as coil heating rises with I².
  • Repeat readings; let the coils cool between runs.

Worked reminders

  • Np = 2000 on 230 V, Vs = 11.5 V: Ns = 100.
  • 230 V at 0.30 A in, 24 V at 2.6 A out: efficiency = 62.4/69.0 = 0.90; wasted 6.6 W.
  • 120 kW through 0.80 Ω at 6.0 kV: I = 20 A, loss 320 W, p.d. lost 16 V.

Exam traps

  • Inverting the turns ratio, giving a step-up answer for a step-down transformer.
  • Efficiency from voltages only, or above 100%.
  • “Energy is lost as heat” with no cause named.
  • “Laminations stop eddy currents.”
  • Using the transmission voltage in I²R or V²/R.
  • Saying a transformer increases power.

Self-test

  1. Why does a transformer not work on a steady dc supply?
  2. Why is the core made of soft iron?
  3. A transformer has 2000 primary turns on 230 V. How many secondary turns give 11.5 V?
  4. An ideal transformer steps 12 V up to 240 V and the secondary current is 0.50 A. Find the primary current.
  5. Find the efficiency: 69 W in, 62.4 W out.
  6. Why are the coils wound one on top of the other?
  7. A transformer is 88% efficient and delivers 150 W. Find the input power.
  8. Power is sent at 600 V instead of 6.0 kV through the same line. By what factor does the power loss change?
  9. Find the line current for 120 kW sent at 600 V.
  10. Find the p.d. lost in 0.80 Ω carrying the current from question 9.
  11. Three stages have efficiencies 96%, 97% and 98%. Find the overall efficiency.
  12. Give one safety rule for Required practical 7.

Answers

  1. A steady current gives a steady flux, so there is no change of flux linkage in the secondary and no emf is induced.
  2. Soft iron is easily magnetised and demagnetised, reducing hysteresis losses, and it concentrates the flux through both coils.
  3. Ns = 2000 × 11.5/230 = 100.
  4. Ip = 240 × 0.50 / 12 = 10 A.
  5. 62.4/69 = 0.90 (90%).
  6. To reduce flux leakage, so that almost all the primary’s flux links the secondary.
  7. 150/0.88 = 170 W.
  8. The current is 10 times larger, so the loss is 100 times larger.
  9. 120 000/600 = 200 A.
  10. 200 × 0.80 = 160 V.
  11. 0.96 × 0.97 × 0.98 = 0.91 (91%).
  12. Use a low-voltage ac supply; never connect a laboratory transformer to the mains.