Study Guides
Cambridge IGCSE Chemistry (0620): Experimental design
Choosing apparatus for time, temperature, mass and volume, judging methods, and the solution and separation terms in Cambridge IGCSE Chemistry 0620 (12.1).
- Subject
- Chemistry
- Level
- IGCSE
- Topic
- Experimental techniques and chemical analysis
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Nouman Ahmed (what this means)
Aligned to Cambridge IGCSE Chemistry (0620), 2026-2028. Official specification .
Syllabus page (what it covers and how it is assessed): Cambridge IGCSE Chemistry.
Syllabus points this page covers, with Core and Extended
0620
- 12.1 Experimental design · Core
"Core and Extended" means part of that syllabus point is Extended only. The page's own tier notes say which part.
Found an error? Report a correction.
Need help with this topic? Request a free trial class for IGCSE Chemistry (0620).
This guide covers subtopic 12.1 Experimental design of Topic 12, Experimental techniques and chemical analysis, in the Cambridge IGCSE Chemistry 0620 syllabus for 2026–2028. All of 12.1 is Core. It underpins the practical papers (Paper 5, the Practical Test, and Paper 6, the Alternative to Practical), and its terms also appear on the theory papers. For quick recall use the experimental design revision notes, and practise with the experimental design practice questions. The broader overview of Topic 12 is in Practical Techniques: Titrations, Chromatography and Separation.
What 12.1 asks you to do
- Name appropriate apparatus for measuring time, temperature, mass and volume, including stop-watches, thermometers, balances, burettes, volumetric pipettes, measuring cylinders and gas syringes.
- Suggest advantages and disadvantages of experimental methods and apparatus.
- Describe six terms: solvent, solute, solution, saturated solution, residue and filtrate.
The practical-assessment section of the syllabus adds the skills that use this knowledge: identifying variables, choosing apparatus and justifying the choice, taking readings to an appropriate precision, recording results and suggesting improvements.
Matching apparatus to the quantity
| Quantity | Apparatus | Typical use and reading |
|---|---|---|
| Time | stop-watch | timing a reaction; the syllabus apparatus list specifies stop-watches that measure to 1 s |
| Temperature | thermometer | the listed thermometers have 1 °C graduations, so read to the nearest 0.5 °C (half a division) |
| Mass | balance | listed balances have a precision of at least 0.1 g |
| Volume of liquid (fixed amount, accurate) | volumetric pipette | delivers one exact volume, such as 25.0 cm³ |
| Volume of liquid (variable amount, accurate) | burette | 50 cm³ burettes; read to the nearest half division |
| Volume of liquid (approximate) | measuring cylinder | quick; sizes from 10 cm³ to 100 cm³ |
| Volume of gas | gas syringe | collects and measures gas produced in a reaction |
Why the choice matters
Each piece of volume apparatus is a compromise between accuracy and convenience:
- A measuring cylinder is fast and can measure many volumes, but its readings are less accurate. Use it when the volume does not need to be exact, such as adding “about 20 cm³” of acid in excess.
- A volumetric pipette is very accurate but measures only one volume. Use it when an exact, fixed volume is needed, such as the solution in the flask in a titration.
- A burette is accurate for any volume within its range, and lets liquid be added a drop at a time. Use it when the volume needed is not known in advance, such as the titre.
- A gas syringe measures gas volume directly. Collecting gas by displacing water from an inverted measuring cylinder is an alternative, but it cannot be used for gases that dissolve readily in water.
Choosing a smaller measuring cylinder for a small volume improves accuracy: 8 cm³ is measured more accurately in a 10 cm³ cylinder than in a 100 cm³ one, because the graduations are finer.
Taking readings
- Read at eye level to avoid parallax error.
- For liquids, read the bottom of the meniscus.
- Read to the nearest half-scale division where required: a thermometer with 1 °C divisions is read to 0.5 °C, so record 23.5 °C, not “about 23 °C”.
- Record readings with consistent precision in a table, with the unit in the column heading, not after each number.
- Burettes read from the top down: 0.00 cm³ is at the top, and the volume added is final reading minus initial reading.
Suggesting advantages and disadvantages
Outcome 2 asks you to judge methods and apparatus, usually in an unfamiliar context. A useful set of headings:
| Heading | Questions to ask |
|---|---|
| Accuracy | Does the apparatus give a reading close to the true value? |
| Precision | Are readings recorded with enough decimal places? |
| Losses | Could gas escape, or solid be lost on transfer? |
| Speed | Will the reading be taken quickly enough as things change? |
| Safety | Is there a hazard, and how is it reduced? |
| Suitability | Can the apparatus measure the size of quantity expected? |
Worked example 1: comparing two methods
A student measures the rate of reaction between marble chips and dilute hydrochloric acid. Method A: measure the volume of carbon dioxide every 30 s with a gas syringe. Method B: measure the loss in mass of the flask every 30 s on a balance, with cotton wool in the neck. Give one advantage and one disadvantage of each.
- Method A, advantage: the gas volume is measured directly; the gas syringe gives clear readings at each time.
- Method A, disadvantage: gas can escape while the bung is put in at the start, and the syringe can stick or reach its maximum volume if too much gas is made.
- Method B, advantage: the flask is not sealed, so there is no delay at the start; the balance gives a reading continuously.
- Method B, disadvantage: the mass of carbon dioxide lost can be small, so a balance reading to only 0.1 g gives imprecise readings. (The cotton wool lets the gas out but stops acid spray escaping, so the mass lost is due to the gas alone.)
The structure is the skill: each point names a specific feature and its effect on the results.
Planning: variables
When you plan an investigation:
- the independent variable is the one you change;
- the dependent variable is the one you measure;
- control variables are kept the same, so the test is fair.
Worked example 2: identifying variables and apparatus
Plan an experiment to find how temperature affects the time for magnesium ribbon to react completely with dilute hydrochloric acid.
- Independent variable: temperature of the acid, measured with a thermometer. Choose about five values across a sensible range, for example from room temperature up to about 60 °C.
- Dependent variable: time for the magnesium to disappear, measured with a stop-watch.
- Control variables: volume of acid (measured with a measuring cylinder), concentration of acid, length or mass of magnesium ribbon.
- Repeats: repeat each temperature and calculate a mean to reduce the effect of random errors.
The six terms in outcome 3
Learn the syllabus wording:
| Term | Description |
|---|---|
| Solvent | a substance that dissolves a solute |
| Solute | a substance that is dissolved in a solvent |
| Solution | a mixture of one or more solutes dissolved in a solvent |
| Saturated solution | a solution containing the maximum concentration of a solute dissolved in the solvent at a specified temperature |
| Residue | a substance that remains after evaporation, distillation, filtration or any similar process |
| Filtrate | a liquid or solution that has passed through a filter |
Two common slips: a saturated solution is defined at a specified temperature, because most solids dissolve more at higher temperatures; and the residue stays in the filter paper while the filtrate passes through.
Applied example: when sand and salt solution are filtered, sand is the residue and salt solution is the filtrate. In that filtrate, salt is the solute and water is the solvent.
Common mistakes
- Choosing a measuring cylinder when the question needs an exact volume for a titration.
- Recording a thermometer reading as a whole number when it should be read to 0.5 °C.
- Writing units in every cell rather than in the column heading.
- Defining a saturated solution without “at a specified temperature”.
- Swapping residue and filtrate.
- Vague evaluations such as “human error” or “more accurate” with no reason.
Exam technique
- Name: give the specific apparatus: “volumetric pipette”, not “pipette” or “measuring device”.
- Suggest (advantage or disadvantage): link a feature to its effect on the result.
- Describe (a term): use the syllabus wording.
- Explain (a choice): say why the alternative is worse.
More resources on this topic
- Experimental design revision notes – condensed recall and self-test
- Experimental design practice questions – original exam-style questions with answers
- Acid–base titrations study guide – burettes and pipettes in use
- Separation and purification study guide – where residue and filtrate come from
Written against the Cambridge IGCSE Chemistry 0620 syllabus for 2026–2028. Always check the current syllabus for your examination year.
Related resources
-
Practice questions
Cambridge IGCSE Chemistry (0620): Experimental design – Practice Questions
Original 0620 practice questions with full answers on choosing apparatus, taking readings, judging methods, variables and solution and filtration terms.
Chemistry · Cambridge · IGCSE
Try questions -
Revision notes
Cambridge IGCSE Chemistry (0620): Experimental design – Revision Notes
Condensed recall for 0620 subtopic 12.1: apparatus for time, temperature, mass and volume, judging methods, variables and the six solution terms.
Chemistry · Cambridge · IGCSE
Revise topic -
Study guides
Cambridge IGCSE Chemistry (0620): Identification of ions and gases
Why each anion, cation, gas and flame test works, how to tell similar results apart and how to deduce an unknown salt for Cambridge IGCSE Chemistry 0620.
Chemistry · Cambridge · IGCSE
Read guide
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.