Skip to content
Marlbridge

Study Guides

Pearson Edexcel International GCSE Physics (4PH1): Electromagnetic induction

Induced voltage, generators, transformer structure, the turns ratio, VpIp = VsIs and high-voltage transmission for Edexcel IGCSE Physics 4PH1 sub-topic 6d.

Subject
Physics
Level
IGCSE
Topic
Magnetism and electromagnetism
Updated

Aligned to Pearson Edexcel IGCSE Physics (4PH1), Issue 4. Official specification .

Syllabus page (what it covers and how it is assessed): Pearson Edexcel IGCSE Physics.

Syllabus points this page covers

4PH1

  • 6d Electromagnetic induction

Found an error? Report a correction.

Need help with this topic? Request a free trial class for IGCSE Physics (4PH1).

This guide covers sub-topic 6(d) Electromagnetic induction of the Pearson Edexcel International GCSE in Physics (4PH1), Issue 4 specification: statements 6.15 to 6.20. Statements 6.15 and 6.16 are core; 6.17P to 6.20P, all on transformers, are Physics-only and assessed on Paper 2P. A shorter overview of the whole topic is in the Magnetism and Electromagnetism study guide. It helps to know the field patterns from the Electromagnetism study guide and P = I × V from Electricity.

What the specification asks for

  • 6.15 know that a voltage is induced in a conductor or a coil when it moves through a magnetic field or when a magnetic field changes through it, and describe the factors that affect the size of the induced voltage
  • 6.16 describe the generation of electricity by the rotation of a magnet within a coil of wire and of a coil of wire within a magnetic field, and describe the factors that affect the size of the induced voltage
  • 6.17P describe the structure of a transformer and understand that a transformer changes the size of an alternating voltage by having different numbers of turns on the input and output sides
  • 6.18P explain the use of step-up and step-down transformers in the large-scale generation and transmission of electrical energy
  • 6.19P know and use the turns-ratio relationship
  • 6.20P know and use input power = output power, VpIp = VsIs, for 100% efficiency

Both transformer equations are on the specification’s list of relationships that are not given in the exam, so learn them.

Inducing a voltage (6.15)

A voltage is induced across a conductor when there is relative movement between it and a magnetic field, so that the conductor “cuts” field lines, or when the magnetic field passing through a coil changes. If the conductor is part of a complete circuit, the induced voltage drives an induced current.

The classic demonstration uses a coil connected to a sensitive centre-zero meter:

Action Meter reading
Push the N pole of a magnet into the coil Deflects one way
Hold the magnet still inside the coil Zero
Pull the magnet out Deflects the opposite way
Push the S pole in Deflects the opposite way to the N pole going in
Push the magnet in faster Larger deflection

The key word is change. A strong magnet sitting still inside a coil induces nothing.

Factors that increase the induced voltage:

  • moving the magnet or conductor faster (a faster rate of change)
  • using a stronger magnet
  • using more turns on the coil
  • (for a coil) winding it on an iron core, which strengthens the field through it

Reversing the direction of motion, or the pole used, reverses the induced voltage.

A magnet and a coil joined to a centre-zero meter in five cases: pushing the N pole in deflects the needle one way, holding still gives zero, pulling out deflects it the other way, pushing the S pole in reverses it, and moving faster gives a larger deflection.
A voltage is induced only while the field through the coil is changing.

Generators (6.16)

A generator turns kinetic energy into electrical energy by keeping the field through a coil continually changing.

A magnet rotating inside a coil. As the magnet turns, each pole in turn sweeps past the coil, so the field through the coil keeps rising, falling and reversing. The induced voltage therefore keeps reversing: the output is alternating. Bicycle dynamos and large power-station generators work this way.

A coil rotating in a magnetic field. As the coil rotates between the poles of a magnet, its sides cut the field lines, first moving one way through the field and then, half a turn later, the other way. The induced voltage reverses every half turn, again giving an alternating output. The voltage is greatest when the sides of the coil move at right angles to the field lines (coil horizontal in the usual diagram) and zero for the instant they move along them (coil vertical).

Factors that increase the induced voltage in a generator:

  • faster rotation: this also increases the frequency of the a.c., since there are more turns per second
  • a stronger magnetic field
  • more turns on the coil
  • (for a rotating coil) a larger area of coil, and a soft iron core inside it

A common exam point: rotating faster changes both the peak voltage and the frequency, while a stronger magnet or more turns change only the peak voltage.

Left: a bar magnet rotates inside a coil connected to a voltmeter. Right: a coil rotating between N and S poles, seen end-on; when the coil is horizontal its sides move at right angles to the field and the voltage is greatest, and when vertical they move along the field and the voltage is zero.
Rotation keeps the field through the coil changing, so an alternating voltage is induced.
Voltage against time for a rotating coil: a wave that is greatest when the coil is horizontal, zero when it is vertical, and reverses every half turn. Small graphs: faster rotation gives a bigger peak and more cycles; a stronger field or more turns gives a bigger peak at the same frequency.
Faster rotation raises both peak voltage and frequency; a stronger field or more turns raises only the peak.

Transformers (6.17P)

A transformer has three parts:

  • a primary (input) coil, connected to an alternating supply
  • a secondary (output) coil, connected to the load
  • a soft iron core linking the two coils (in practice made of thin insulated sheets, called laminations, to reduce energy losses)

The coils are not electrically connected to each other. The alternating current in the primary coil produces a magnetic field in the core that is continually changing in size and direction. The core carries this changing field through the secondary coil, so an alternating voltage is induced in the secondary.

A transformer does not work with d.c.: a steady current gives a steady field, and a steady field induces no voltage.

Step-up transformers have more turns on the secondary than on the primary, so the output voltage is larger. Step-down transformers have fewer secondary turns, so the output voltage is smaller.

A soft iron core with a primary coil on one side connected to an a.c. supply and a secondary coil with more turns on the other side connected to a load. Step-up transformers have more secondary turns; step-down have fewer.
Alternating current in the primary makes a changing field that induces a voltage in the secondary.

The equations (6.19P, 6.20P)

input (primary) voltage / output (secondary) voltage = primary turns / secondary turns
Vp / Vs = Np / Ns

input power = output power (100% efficiency)
Vp × Ip = Vs × Is

The second equation means that a transformer that steps the voltage up steps the current down by the same factor, and the other way round.

Transmission of electrical energy (6.18P)

Power stations generate at a voltage of tens of kilovolts. A step-up transformer raises this to hundreds of kilovolts for the transmission lines. Because P = V × I, transmitting the same power at a higher voltage needs a smaller current. A smaller current causes less heating of the cables, so less energy is wasted. Step-down transformers near towns and homes then reduce the voltage to a safer value for consumers.

A power station generates at tens of kilovolts; a step-up transformer raises this to hundreds of kilovolts for the lines; a step-down transformer lowers it for homes. Sending 100 MW at 25 kV needs 4000 A, but at 400 kV only 250 A.
Same power at a higher voltage means a smaller current and less heating in the cables.

Worked examples

Example 1 (turns ratio). A charger’s transformer has 2000 primary turns and runs from a 230 V supply. It must give an output of 11.5 V. Calculate the number of secondary turns.

Vp / Vs = Np / Ns
230 / 11.5 = 2000 / Ns
Ns = 2000 × 11.5 / 230 = 100 turns

Example 2 (power and current). A transformer, assumed 100% efficient, supplies 2.0 A to a device at 12 V from a 230 V primary. Calculate the primary current.

Vp × Ip = Vs × Is
230 × Ip = 12 × 2.0 = 24 W
Ip = 24 / 230 = 0.10 A (2 s.f.)

Example 3 (why step up?). Illustrative figures. A power station sends 100 MW. At 25 kV, the current would be I = P / V = 100 000 000 / 25 000 = 4000 A. Stepped up to 400 kV (a turns ratio of 1 : 16), the current is 100 000 000 / 400 000 = 250 A, sixteen times smaller, so the cables are heated far less.

Example 1: with 2000 primary turns, 230 V in and 11.5 V out, Ns = 2000 × 11.5 / 230 = 100 turns. Example 2: 12 V at 2.0 A is 24 W, so the primary current from 230 V is 24 / 230 = 0.10 A.
Use the turns ratio for voltages and power in = power out for currents.

Common mistakes

  • Saying a voltage is induced by a magnet “being near” a coil. It needs movement or a changing field.
  • Writing that a transformer “makes more power” when it steps up voltage. Power out cannot exceed power in.
  • Inverting the ratio: check that the larger voltage is on the side with more turns.
  • Stating that high-voltage transmission reduces resistance. It reduces the current; the cables’ resistance is unchanged.
  • Claiming the coils of a transformer are connected by wire. The link is the changing magnetic field in the core.
  • Forgetting that faster rotation raises the frequency as well as the voltage.

Exam technique

  • Calculate: write the equation, substitute with units, and give the answer with a unit and sensible significant figures.
  • Explain (transmission): chain three links: higher voltage → lower current for the same power → less heating, less energy wasted.
  • Describe (transformer structure): name all three parts and say what each is connected to.
  • Describe the factors (6.15, 6.16): use comparatives (“faster”, “stronger”, “more turns”) linked to “larger induced voltage”.

More resources on this topic

Written against the Pearson Edexcel International GCSE in Physics (4PH1) specification, Issue 4. Always check the current specification for your examination year.

Related resources

Related articles

Get free revision emails (optional)

Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.