Revision Notes
OCR A Level Chemistry A (H432): Evaluation – Revision Notes
Condensed OCR H432 1.1.4 revision notes: precision and accuracy, percentage error and uncertainty, anomalies, limitations and improvements, with a self-test.
- Subject
- Chemistry
- Level
- A LEVELS
- Topic
- Module 1: Development of practical skills in chemistry
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Nouman Ahmed (what this means)
Aligned to OCR A Level Chemistry (H432), Version 3.1 (May 2026), for first assessment in 2017. Official specification .
Syllabus page (what it covers and how it is assessed): OCR A Level Chemistry.
Syllabus points this page covers
H432
- 1.1.4 Evaluation
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Chemistry (H432).
These notes condense 1.1.4 Evaluation in OCR A Level Chemistry A (H432), Version 3.1 (May 2026). The five learning outcomes are (a) evaluating results and drawing conclusions (HSW6); (b) identifying anomalies; (c) limitations in experimental procedures; (d) precision and accuracy, including margins of error, percentage errors and uncertainties in apparatus (M1.3); and (e) refining a design by suggesting improvements to procedures and apparatus (HSW3). Section 1.1 is assessed in the written papers.
Worked evaluations are in the 1.1.4 study guide. Exam-style questions are in the 1.1.4 practice questions. For all four written-paper skills together, use the practical skills revision notes.
Key terms
| Term | Meaning |
|---|---|
| Accurate | Close to the true or accepted value |
| Precise | Repeated results close to one another |
| Uncertainty | The range, ± a value, within which the true value is expected to lie |
| Margin of error | The absolute uncertainty of a result, giving its range |
| Percentage uncertainty | Absolute uncertainty ÷ measured value × 100 |
| Percentage error | (Experimental − accepted) ÷ accepted × 100 |
| Random error | Unpredictable scatter either side of the true value; reduced by repeats |
| Systematic error | A shift in the same direction every time; not reduced by repeats |
| Anomaly | A result that does not fit the pattern of the others |
| Limitation | A specific weakness of the procedure that affects the result |
| Constant mass | Heating, cooling and weighing repeated until two masses agree |
1.1.4(a): evaluating a result in four steps
- Calculate the percentage error against the accepted value.
- Calculate the total percentage uncertainty from the apparatus.
- Compare them: error within uncertainty means the result agrees within its margin of error; error larger than uncertainty points to a systematic error.
- Name the limitation that explains the direction of the error, and an improvement that fixes it.
1.1.4(b): anomalies
- Spot it: a repeat far from the others, or a point well off a graph’s trend.
- Leave it out of the mean and the best-fit line; say that you have.
- Repeat the measurement if possible.
- A cause you suggest must fit the direction: a time that is too long needs a reason the reaction was slower or the timing longer.
1.1.4(d): uncertainties
Per reading.
- Use the value given for the apparatus if one is stated.
- Otherwise ± half the smallest division for an analogue scale, or as stated for a digital display.
Combining.
quantity from two readings (titre, ΔT, mass by difference): uncertainty × 2
result from × or ÷ of measurements: add the percentage uncertainties
Reducing percentage uncertainty.
- Measure a larger quantity: a bigger titre, mass or temperature change.
- Use apparatus with a smaller uncertainty: a burette or pipette instead of a measuring cylinder, a three-decimal-place balance.
1.1.4(c) and (e): limitations with improvements
| Limitation | Direction of effect | Improvement |
|---|---|---|
| Heat lost in calorimetry | ΔH less exothermic | Insulate and lid; extrapolate a temperature–time graph |
| Gas escapes before sealing | Volume too low | Keep reactants apart until the flask is sealed |
| Gas dissolves in water | Volume too low | Gas syringe |
| Subjective end point (cross, colour) | Random scatter | Light sensor or colorimeter |
| Hydrated salt not fully dehydrated | x too low | Heat to constant mass |
| Anhydrous salt decomposes | x too high | Heat gently |
| Titration end point overshot | Titre too high | Add dropwise near the end point |
| Small reading (titre, ΔT, mass) | Large percentage uncertainty | Use larger quantities |
Rules for improvements. Each must fix a named limitation, be specific about the apparatus or step, and not simply say “repeat” (repeats reduce random error but cannot remove a systematic one).
Exam traps
- Precise is not accurate. Close repeats can all be wrong in the same direction.
- Two readings, double uncertainty. Titres, temperature changes and masses by difference.
- Add percentages, not absolute values, when combining measurements multiplied or divided.
- Wrong direction. Heat loss makes ΔH less exothermic; it cannot explain a value more exothermic than data.
- Vague improvements: “use more accurate equipment” without naming it.
- “Repeat it” for systematic error.
- Anomalies silently included in the mean.
Quick self-test
- Explain the difference between precise and accurate results.
- A thermometer is marked every 0.5 °C. State the uncertainty in one reading and in a temperature change.
- A titre is 15.20 cm³ from two burette readings each ±0.05 cm³. Calculate the percentage uncertainty.
- Give two ways to reduce the percentage uncertainty in the titre in question 3.
- An experimental ΔH is −52.1 kJ mol⁻¹; the accepted value is −57.0 kJ mol⁻¹. Calculate the percentage error.
- The total percentage uncertainty in question 5 was 2.5%. What does this suggest?
- Repeats give 4.52, 4.49, 4.95 and 4.50 g. Identify the anomaly and give the mean.
- A result is 1.25 ± 0.03 mol dm⁻³; the accepted value is 1.27 mol dm⁻³. Does the result agree within its margin of error?
- Magnesium ribbon is dropped into acid, then the bung is replaced quickly and hydrogen collected. Give the limitation, its effect and an improvement.
- Why does repeating an experiment not remove a systematic error?
- A hydrated salt is heated very strongly and the anhydrous salt begins to decompose. What happens to the calculated value of x?
- A volume has a 0.5% uncertainty and a mass has a 0.8% uncertainty. What is the percentage uncertainty in a concentration in g dm⁻³ calculated from them?
Answers
- Precise: repeats are close to each other. Accurate: the result is close to the true or accepted value.
- One reading ±0.25 °C; temperature change ±0.5 °C (two readings).
- 0.10 ÷ 15.20 × 100 = 0.66%.
- Use a more dilute titrant (larger titre), or titrate a larger pipetted volume; either gives a larger titre for the same ±0.10 cm³.
- Difference = 57.0 − 52.1 = 4.9 kJ mol⁻¹; 4.9 ÷ 57.0 × 100 = 8.6%, with the experimental value less exothermic than accepted.
- 8.6% is larger than 2.5%, so the apparatus cannot explain the difference: there is a systematic error, such as heat loss.
- 4.95 g is anomalous; mean of 4.52, 4.49 and 4.50 = 4.50 g.
- Yes: the range is 1.22 to 1.28 mol dm⁻³, which includes 1.27.
- Hydrogen escapes before the bung is replaced, so the volume is too low. Keep the magnesium apart from the acid (for example in a small tube inside the flask) until the flask is sealed.
- A systematic error shifts every result in the same direction, so averaging repeats gives the same wrong value.
- Extra mass is lost, so the “water lost” is too large and x is too high.
- 1.3% (0.5% + 0.8%).
Official syllabus
OCR A Level Chemistry A (H432) specification, Version 3.1 (May 2026), for first assessment in 2017, published by OCR. Module 1, section 1.1.4 Evaluation.
Related resources
-
Study guides
OCR A Level Chemistry A (H432): Practical skills
OCR H432 1.2.1 in depth: the ten practical skills mapped to CPAC, risk assessments, lab records, spreadsheets, and researching and citing sources.
Chemistry · OCR · A Level
Read guide -
Practice questions
OCR A Level Chemistry A (H432): Practical skills – Practice Questions
Original OCR H432 1.2.1 questions: hazards and risks, CPAC links, lab records, spreadsheets, data loggers, investigations and citing sources, with mark schemes.
Chemistry · OCR · A Level
Try questions -
Revision notes
OCR A Level Chemistry A (H432): Practical skills – Revision Notes
Condensed OCR H432 1.2.1 revision notes: the ten practical skills, CPAC links, hazards and risks, lab records, software and citing sources, with a self-test.
Chemistry · OCR · A Level
Revise topic
Related articles
Get free revision emails (optional)