Study Guides
OCR A Level Chemistry A (H432): Evaluation
OCR H432 1.1.4 in depth: judging results against uncertainty, handling anomalies, naming limitations, combining uncertainties and matching improvements.
- Subject
- Chemistry
- Level
- A LEVELS
- Topic
- Module 1: Development of practical skills in chemistry
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Nouman Ahmed (what this means)
Aligned to OCR A Level Chemistry (H432), Version 3.1 (May 2026), for first assessment in 2017. Official specification .
Syllabus page (what it covers and how it is assessed): OCR A Level Chemistry.
Syllabus points this page covers
H432
- 1.1.4 Evaluation
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Chemistry (H432).
This guide goes deeper into 1.1.4 Evaluation in OCR A Level Chemistry A (H432), Version 3.1 (May 2026), for first assessment in 2017. Evaluation is assessed in the written papers and usually comes at the end of a practical question, after the results have been processed.
The practical skills in the written examination guide covers 1.1.1 to 1.1.4 together, with an enthalpy evaluation. This page covers evaluation alone, with different examples: using spread and error to judge precision and accuracy, deciding what to do with an anomaly, a bank of limitations with matching improvements, combining apparatus uncertainties for a titration, and a full evaluation of a water of crystallisation result. Condense it with the 1.1.4 revision notes and test yourself with the 1.1.4 practice questions.
The five statements
| Statement | Learners should be able to demonstrate and apply their knowledge and understanding of: | Linked skill |
|---|---|---|
| 1.1.4(a) | how to evaluate results and draw conclusions | HSW6 |
| 1.1.4(b) | the identification of anomalies in experimental measurements | – |
| 1.1.4(c) | the limitations in experimental procedures | – |
| 1.1.4(d) | precision and accuracy of measurements and data, including margins of error, percentage errors and uncertainties in apparatus | M1.3 |
| 1.1.4(e) | refining experimental design by suggestion of improvements to the procedures and apparatus | HSW3 |
M1.3 is “identify uncertainties in measurements and use simple techniques to determine uncertainty when data are combined”, with the example of finding the uncertainty in a titre from two burette readings.
1.1.4(a) and (d): precision, accuracy and error
- Precision is about the spread of repeated results. Results that are close together are precise. The range of repeats is a quick measure of it.
- Accuracy is about closeness to the true or accepted value. It is judged with the percentage error.
percentage error = (experimental value − accepted value) ÷ accepted value × 100
percentage uncertainty = absolute uncertainty ÷ measured value × 100
A set of results can be precise but inaccurate (close together, all too low) or accurate on average but imprecise (widely spread around the true value).
The key comparison
Compare the percentage error with the total percentage uncertainty from the apparatus.
| Finding | What it suggests |
|---|---|
| Percentage error ≤ total percentage uncertainty | The difference can be explained by apparatus uncertainty; the result agrees with the accepted value within its margin of error |
| Percentage error > total percentage uncertainty | Apparatus uncertainty cannot explain it; look for a systematic error from a limitation in the procedure |
The margin of error of a result is its absolute uncertainty. A result of 0.0898 ± 0.0007 mol dm⁻³ lies somewhere between 0.0891 and 0.0905 mol dm⁻³.
1.1.4(b): anomalies
An anomaly is a measurement that does not fit the pattern of the others.
Worked example 1. Times for a cross to disappear at 40 °C are 31 s, 33 s, 46 s and 32 s.
- 46 s is anomalous: it is far from the other three, which agree within 2 s.
- Leave it out of the mean: (31 + 33 + 32) ÷ 3 = 32 s.
- Repeat the measurement if possible.
- Suggest a cause that fits a time that is too long: for example, the stopwatch was started before the acid was added, or the mixture had cooled below 40 °C.
On a graph, an anomalous point lies well off the trend of the others. Do not draw the best-fit line through it; circle it and say why it was ignored.
1.1.4(c) and (e): limitations and improvements
A limitation is a specific weakness of the procedure that affects the result. Every improvement you suggest must fix a limitation you have named. “Use better equipment” or “be more careful” earns nothing; say which equipment and why.
| Experiment type | Limitation | Effect on result | Improvement |
|---|---|---|---|
| Calorimetry (solution) | Heat lost to surroundings | ΔT too small; ΔH less exothermic | Insulated cup with lid; plot temperature against time and extrapolate |
| Combustion with a spirit burner | Heat lost; incomplete combustion | ΔH much less exothermic than data | Shield the flame; put the beaker closer; use a calorimeter designed for combustion |
| Gas collection | Gas escapes while the bung is replaced | Volume too low | Put the solid in a separate small tube inside the flask, then tip it over after sealing |
| Gas over water | Gas partly dissolves | Volume too low | Use a gas syringe |
| Timing a visual end point | Judging when a cross disappears is subjective | Random scatter in times | Use a light sensor or colorimeter |
| Heating a hydrated salt | Not all water removed | Too little water; x too small | Heat to constant mass |
| Heating a hydrated salt | Strong heating decomposes the anhydrous salt | Extra mass lost; x too large | Heat gently and steadily |
| Titration | End point overshot | Titre too large | Add dropwise near the end point, swirling |
1.1.4(d): uncertainties in apparatus
- If a question gives an apparatus uncertainty (often printed on glassware), use that value.
- Otherwise, take the uncertainty of a reading as half the smallest division for a scale you read, or ± 1 in the last digit shown by a digital instrument, as the question tells you.
- A quantity found from two readings (titre, temperature change, mass by difference) has twice the uncertainty of one reading.
- For a result found by multiplying or dividing measurements, add the percentage uncertainties.
Worked example 2: a titration’s total uncertainty. A 25.0 cm³ pipette (±0.06 cm³), a 250.0 cm³ volumetric flask (±0.3 cm³) and a burette (±0.05 cm³ per reading) give a mean titre of 22.50 cm³.
pipette: 0.06 ÷ 25.0 × 100 = 0.24%
volumetric flask: 0.3 ÷ 250.0 × 100 = 0.12%
titre: (2 × 0.05) ÷ 22.50 × 100 = 0.44%
total percentage uncertainty ≈ 0.80%
The titre is the largest contribution. It could be reduced by using a more dilute titrant, giving a larger titre, or a larger pipetted volume. A larger titre with the same ±0.10 cm³ gives a smaller percentage.
Full evaluation: water of crystallisation
Worked example 3. A student heats hydrated copper(II) sulfate, CuSO₄·xH₂O, in a crucible once, for five minutes, and finds:
| Reading | Mass / g |
|---|---|
| Empty crucible | 15.214 |
| Crucible + hydrated salt | 17.711 |
| Crucible + residue after heating | 16.900 |
Use Mr(CuSO₄) = 159.6 and Mr(H₂O) = 18.0. The balance reads to ±0.001 g. The accepted value of x is 5.
Result.
mass of residue (taken as CuSO₄) = 16.900 − 15.214 = 1.686 g → 1.686 ÷ 159.6 = 0.01056 mol
mass of water lost = 17.711 − 16.900 = 0.811 g → 0.811 ÷ 18.0 = 0.04506 mol
x = 0.04506 ÷ 0.01056 = 4.27
Percentage error. (4.27 − 5) ÷ 5 × 100 = −14.6%.
Percentage uncertainty. Each mass by difference is ±0.002 g. Water: 0.002 ÷ 0.811 × 100 = 0.25%. Residue: 0.002 ÷ 1.686 × 100 = 0.12%. Total ≈ 0.37%.
Evaluation. The error (about 15%) is far larger than the uncertainty (about 0.4%), so the balance cannot explain the difference. The value of x is too low, which fits not all the water being removed: the residue still contained water, so its mass was too high and the water lost too low. The student heated only once. Improvement: heat, cool and reweigh repeatedly until two successive masses agree (heating to constant mass). This tests directly whether all the water has gone.
Notice the structure: result, error, uncertainty, comparison, the limitation that explains the direction of the error, and an improvement that fixes that limitation.
Common mistakes
- Calling results “accurate” because they are close together; that is precision.
- Using one reading’s uncertainty for a quantity found from two readings.
- Adding absolute uncertainties of measurements in different units instead of percentage uncertainties.
- Naming a limitation that would change the result in the opposite direction to the error found.
- Suggesting improvements that do not fix a named limitation, such as “repeat the experiment” for a systematic error.
- Leaving an anomaly in a mean or a best-fit line without comment.
Exam technique
- “Evaluate”: give the comparison of error with uncertainty, a judgement, and the main limitation.
- “Suggest an improvement”: name the change, and say which limitation it fixes and how the result would change.
- “Explain whether the result is accurate”: quote the percentage error and compare it with the uncertainty.
- Direction matters: say whether a limitation makes the result too high or too low, and check that this matches the data.
- Condensed recall: 1.1.4 revision notes
- Test yourself: 1.1.4 practice questions
- Before this: 1.1.3 Analysis; then the endorsement skills in 1.2.1 Practical skills
- The OCR A Level Chemistry hub
Official syllabus
OCR A Level Chemistry A (H432) specification, Version 3.1 (May 2026), for first assessment in 2017, published by OCR. Module 1, section 1.1.4 Evaluation, learning outcomes (a) to (e), with additional guidance and the links to HSW3, HSW6 and M1.3.
Related resources
-
Practice questions
OCR A Level Chemistry A (H432): Evaluation – Practice Questions
Original OCR H432 1.1.4 questions: precision and accuracy, percentage error and uncertainty, anomalies, limitations and improvements, with mark schemes.
Chemistry · OCR · A Level
Try questions -
Revision notes
OCR A Level Chemistry A (H432): Evaluation – Revision Notes
Condensed OCR H432 1.1.4 revision notes: precision and accuracy, percentage error and uncertainty, anomalies, limitations and improvements, with a self-test.
Chemistry · OCR · A Level
Revise topic -
Study guides
OCR A Level Chemistry A (H432): Practical skills
OCR H432 1.2.1 in depth: the ten practical skills mapped to CPAC, risk assessments, lab records, spreadsheets, and researching and citing sources.
Chemistry · OCR · A Level
Read guide
Related articles
Get free revision emails (optional)