Revision Notes
Cambridge A Level Chemistry (9701): Standard electrode potentials, standard cell potentials and the Nernst equation – Revision Notes
Revision notes on E⦵ and E⦵cell for Cambridge 9701: definitions, the hydrogen electrode, measurement set-ups, feasibility, the Nernst equation and ΔG = −nEF.
- Subject
- Chemistry
- Level
- A LEVEL
- Topic
- Electrochemistry
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Farhat ul Ain Sehgal (what this means)
Aligned to Cambridge A Level Chemistry (9701), 2025-2027. Official specification .
Syllabus page (what it covers and how it is assessed): Cambridge A Level Chemistry.
Syllabus points this page covers
9701 (A Level)
- 24.2 Standard electrode potentials, standard cell potentials and the Nernst equation
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Chemistry (9701).
Condensed for revision. For full explanations and worked examples, use the Electrode potentials and Nernst equation study guide, then test yourself with the Electrode potentials and Nernst equation practice questions.
Syllabus: Cambridge International AS & A Level Chemistry 9701, 2025–2027, A Level subtopic 24.2.
Key terms
| Term | Meaning |
|---|---|
| Standard electrode (reduction) potential, E⦵ | potential of a half-cell relative to the standard hydrogen electrode, under standard conditions, for the reduction half-equation |
| Standard conditions | 298 K; 1.00 mol dm⁻³ aqueous ions; 101 kPa for gases |
| Standard cell potential, E⦵cell | potential difference between two half-cells under standard conditions, with no current flowing |
| Salt bridge | filter paper soaked in saturated KNO₃(aq); lets ions move to complete the circuit without mixing the solutions |
| High-resistance voltmeter | measures the potential difference while drawing almost no current |
| Oxidising agent | species that is reduced, accepting electrons |
| Reducing agent | species that is oxidised, donating electrons |
The standard hydrogen electrode (SHE)
- H₂(g) at 101 kPa bubbled over platinum (platinised for large surface area).
- H⁺(aq) at 1.00 mol dm⁻³.
- 298 K. Half-equation: 2H⁺(aq) + 2e⁻ ⇌ H₂(g), E⦵ = 0.00 V by definition.
Measuring E⦵: three set-ups
| Half-cell type | Electrode | Solution |
|---|---|---|
| metal / metal ion (e.g. Ni²⁺/Ni) | the metal | 1.00 mol dm⁻³ Ni²⁺(aq) |
| non-metal / ion (e.g. Cl₂/Cl⁻) | platinum, with Cl₂ at 101 kPa bubbled over it | 1.00 mol dm⁻³ Cl⁻(aq) |
| two ions of one element (e.g. Fe³⁺/Fe²⁺) | platinum | 1.00 mol dm⁻³ of each ion (plus 1.00 mol dm⁻³ H⁺ if H⁺ is in the half-equation) |
Each is connected to the SHE by a salt bridge and a high-resistance voltmeter.
Cell potential, polarity and electron flow
E⦵cell = E⦵(more positive) − E⦵(less positive)
- More positive E⦵ → positive electrode, reduction.
- Less positive E⦵ → negative electrode, oxidation.
- Electrons flow in the external wire from negative to positive.
Example: Al³⁺/Al (−1.66 V) and Pb²⁺/Pb (−0.13 V).
E⦵cell = −0.13 − (−1.66) = +1.53 V
Al is negative; electrons flow from Al to Pb
Overall: 2Al + 3Pb²⁺ → 2Al³⁺ + 3Pb (n = 6)
Reading a table of E⦵ values
- Most positive E⦵: left-hand species is the strongest oxidising agent.
- Most negative E⦵: right-hand species is the strongest reducing agent.
- A species on the left will oxidise a species on the right of any half-equation with a less positive E⦵.
Feasibility routine
- Write both half-equations as reductions with E⦵.
- Identify which species would be reduced in the proposed reaction.
- E⦵cell = E⦵(reduced species’ half-cell) − E⦵(oxidised species’ half-cell).
- Positive → feasible under standard conditions.
- Add caveats if asked: rate may be slow; non-standard concentrations change E.
Constructing a redox equation
- Reverse the half-equation for the species being oxidised (do not change E⦵ values when multiplying).
- Multiply so that electrons lost = electrons gained.
- Add; cancel electrons, H⁺ and H₂O that appear on both sides.
- Check atoms and total charge.
Example: MnO₄⁻ (+1.52 V) with Fe²⁺ (Fe³⁺/Fe²⁺ +0.77 V): E⦵cell = +0.75 V.
MnO₄⁻ + 8H⁺ + 5Fe²⁺ → Mn²⁺ + 5Fe³⁺ + 4H₂O
The Nernst equation
E = E⦵ + (0.059 / z) log([oxidised species] / [reduced species])
- z = electrons in the half-equation.
- Solids (metals) are left out: for Cu²⁺/Cu, E = E⦵ + (0.059/2) log[Cu²⁺].
- More oxidised species → E more positive; less oxidised species → E less positive.
Example: Cu²⁺/Cu with [Cu²⁺] = 0.200 mol dm⁻³:
E = 0.34 + 0.0295 × log(0.200) = 0.34 − 0.021 = +0.319 V
Effect on a cell: making the positive half-cell less positive, or the negative half-cell less negative, reduces Ecell.
ΔG⦵ = −nE⦵cellF
- n = electrons transferred in the overall equation; F = 9.65 × 10⁴ C mol⁻¹.
- Gives J mol⁻¹; divide by 1000 for kJ mol⁻¹.
- Al/Pb example: ΔG⦵ = −6 × 1.53 × 96 500 = −886 000 J mol⁻¹ = −886 kJ mol⁻¹.
Exam traps
- Include “relative to the standard hydrogen electrode” in the definition of E⦵.
- Never multiply E⦵ values when balancing electrons.
- Platinum electrode for gas/ion and ion/ion half-cells.
- Both ions at 1.00 mol dm⁻³ for an Fe³⁺/Fe²⁺ half-cell (equal concentrations).
- Electrons flow through the wire; ions flow through the salt bridge.
- A positive E⦵cell means feasible, not fast.
- In ΔG = −nEF use the overall n; in the Nernst equation use z for the single half-equation.
- High-resistance voltmeter: so that no current flows and concentrations stay constant.
Self-test
- Define standard electrode potential.
- Why is platinum used in the standard hydrogen electrode?
- Describe the half-cell used to measure E⦵ for Fe³⁺/Fe²⁺.
- Calculate E⦵cell for Fe²⁺/Fe (−0.44 V) with Cu²⁺/Cu (+0.34 V).
- For the cell in Question 4, which electrode is negative and which way do electrons flow?
- Calculate ΔG⦵ for the cell in Question 4.
- Using I₂/I⁻ +0.54 V and Fe³⁺/Fe²⁺ +0.77 V, which of Fe³⁺ and I₂ is the stronger oxidising agent?
- Write the equation for the feasible reaction between the species in Question 7.
- State the effect on E of Fe³⁺/Fe²⁺ of increasing [Fe²⁺].
- Calculate E for Fe³⁺/Fe²⁺ when [Fe³⁺] = 0.0200 and [Fe²⁺] = 0.200 mol dm⁻³.
- Why is a high-resistance voltmeter used?
- Give two reasons why a reaction predicted to be feasible may not be observed.
Answers
- The potential of a half-cell relative to the standard hydrogen electrode, measured at 298 K with 1.00 mol dm⁻³ ions and 101 kPa gas pressure.
- It is inert, conducts electricity and provides a surface for the H⁺/H₂ equilibrium.
- Platinum electrode in a solution containing 1.00 mol dm⁻³ Fe³⁺ and 1.00 mol dm⁻³ Fe²⁺ at 298 K.
- 0.34 − (−0.44) = +0.78 V.
- Iron is negative; electrons flow through the wire from iron to copper.
- −2 × 0.78 × 96 500 = −150 540 J mol⁻¹ = −151 kJ mol⁻¹.
- Fe³⁺ (more positive E⦵).
- 2Fe³⁺ + 2I⁻ → 2Fe²⁺ + I₂.
- E becomes less positive.
- E = 0.77 + 0.059 log(0.100) = 0.77 − 0.059 = +0.711 V.
- So that almost no current flows and the concentrations in the half-cells do not change.
- The activation energy may be high, so the rate is very slow; conditions may be non-standard, changing the electrode potentials.
These are original notes written for revision. E⦵ values are those commonly listed in data tables; always use the values given in the question. Check the full wording in the official 9701 syllabus.
Related resources
-
Study guides
Electrochemistry: Electrolysis and Standard Electrode Potentials
Quantitative electrolysis, the standard hydrogen electrode, cell potentials, feasibility and the Nernst equation, for Cambridge A Level Chemistry 9701.
Chemistry · Cambridge · A Level
Read guide -
Practice questions
A Level Chemistry: Electrochemistry — Practice Questions
Original exam-style practice questions with full worked answers on electrode potentials, cell e.m.f. and electrolysis for Cambridge A Level Chemistry 9701.
Chemistry · Cambridge · A Level
Try questions -
Revision notes
A Level Chemistry: Electrochemistry — Revision Notes
Condensed recall notes on standard electrode potentials, cell e.m.f., feasibility and electrolysis for Cambridge A Level Chemistry 9701.
Chemistry · Cambridge · A Level
Revise topic
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.