Practice Questions
Cambridge A Level Chemistry (9701): Gas/liquid chromatography – Practice Questions
Original practice questions with full answers on GLC phases, retention times, peak-area percentages and explaining elution order, for Cambridge 9701 Chemistry.
- Subject
- Chemistry
- Level
- A LEVEL
- Topic
- Analytical techniques
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Farhat ul Ain Sehgal (what this means)
Aligned to Cambridge A Level Chemistry (9701), 2025-2027. Official specification .
Syllabus page (what it covers and how it is assessed): Cambridge A Level Chemistry.
Syllabus points this page covers
9701 (A Level)
- 37.2 Gas / liquid chromatography
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Chemistry (9701).
These are original questions written for Marlbridge, for revision and practice on this content. They are not reproduced past-paper questions, and they do not replicate the exam’s exact structure, question count or mark tariffs — examination boards hold copyright in their own papers. Use these alongside the official past papers available free from your board.
Related: Gas/liquid chromatography study guide and revision notes, for subtopic 37.2 of Cambridge A Level Chemistry 9701. In every question the stationary phase is a non-polar liquid on a solid support, and peak-area percentages are taken as the percentage composition.
Section A
1. Explain why the stationary phase must have a high boiling point. [1]
2. Explain why the mobile phase must be an unreactive gas. [1]
3. State the point on a peak at which retention time is read. [1]
4. A chromatogram has three peaks with areas 18.0, 54.0 and 28.0. Calculate the percentage of the first component. [1]
Section B
5. A chromatogram of a four-component mixture has triangular peaks.
| Peak | Base width / min | Height / arbitrary units |
|---|---|---|
| A | 0.20 | 9.0 |
| B | 0.40 | 6.0 |
| C | 0.30 | 4.0 |
| D | 0.50 | 2.4 |
(a) Calculate the area of each peak. [2]
(b) Calculate the percentage of component B in the mixture. [1]
(c) Explain why using peak heights alone would give the wrong composition for this mixture. [1]
6. Pure samples of three alcohols are run under fixed conditions: methanol 1.6 min, ethanol 2.3 min, propan-1-ol 3.5 min. A mixture run under the same conditions gives peaks at 2.3 min and 3.5 min.
(a) Identify the alcohols probably present in the mixture. [1]
(b) Explain why propan-1-ol has a longer retention time than ethanol. [2]
(c) State why the mixture must be run under the same conditions as the pure samples. [1]
7. Pentane, 2-methylbutane and 2,2-dimethylpropane all have the formula C₅H₁₂.
(a) Predict the order in which they reach the detector, first to last. [1]
(b) Explain your order. [2]
8. State and explain the effect on retention times of each change.
(a) The carrier gas flow rate is increased. [1]
(b) The column temperature is lowered. [2]
9. A 250 g sample of a fuel blend is analysed. The ethanol peak is 8.0% of the total peak area. Calculate the mass of ethanol in the sample. [1]
10. Suggest why GLC cannot be used to separate a mixture of sodium chloride and potassium chloride. [1]
11. Two components of a mixture give a single peak on one column. Suggest how the analyst could show that two components are present. [2]
12. A chromatogram of a hydrocarbon mixture shows three peaks.
| Retention time / min | Peak area |
|---|---|
| 1.9 | 0.60 |
| 2.7 | 3.6 |
| 4.1 | 1.2 |
Under the same conditions, pure hexane has a retention time of 2.7 min and pure heptane 4.1 min.
(a) The third component is either pentane or octane. Identify it and explain your choice. [2]
(b) Calculate the percentage of hexane in the mixture. [1]
Answers
1. So that it stays liquid in the heated column and is not vaporised and carried away by the gas [1].
2. So that it does not react with the sample or the stationary phase, letting the components reach the detector unchanged [1].
3. At the maximum (top) of the peak [1].
4. 18.0 / 100.0 × 100 = 18.0% [1].
5. (a) A: ½ × 0.20 × 9.0 = 0.90; B: ½ × 0.40 × 6.0 = 1.2; C: ½ × 0.30 × 4.0 = 0.60; D: ½ × 0.50 × 2.4 = 0.60. All four correct [2] (one mark if two or three are correct).
(b) Total = 3.3, so B = 1.2 / 3.3 × 100 = 36.4% [1].
(c) The peaks have different widths, so height is not proportional to area (A is tallest but B has the largest area) [1].
6. (a) Ethanol and propan-1-ol [1].
(b) Propan-1-ol has more electrons (a longer chain), so it has stronger instantaneous dipole–induced dipole attractions to the non-polar stationary phase [1]; it dissolves more in the stationary phase and spends longer there, so it takes longer to reach the detector [1].
(c) Retention time depends on conditions such as temperature, flow rate and column, so only times measured under identical conditions can be compared [1].
7. (a) 2,2-dimethylpropane, then 2-methylbutane, then pentane [1].
(b) All three have the same number of electrons, but more branching gives a more compact molecule with less surface contact [1]; so attractions to the stationary phase are weakest for 2,2-dimethylpropane and strongest for pentane, giving the shortest and longest retention times [1].
8. (a) Retention times decrease, because the components are carried through the column faster [1].
(b) Retention times increase [1]; at a lower temperature the components spend more time dissolved in the stationary liquid and less time as vapour in the gas [1].
9. 0.080 × 250 = 20.0 g [1].
10. Ionic salts are not volatile, so they cannot be vaporised and carried by the gas [1].
11. Repeat the analysis under different conditions, for example with a different stationary phase or column temperature [1]; if two peaks appear, or the peak’s retention time no longer matches a single reference, more than one component is present [1].
12. (a) Pentane [1]: its retention time (1.9 min) is shorter than hexane’s, and pentane, with fewer electrons, has weaker attractions to the stationary phase than hexane, while octane would have a longer retention time than heptane [1].
(b) Total area = 0.60 + 3.6 + 1.2 = 5.4; hexane = 3.6 / 5.4 × 100 = 66.7% [1].
Where marks are usually lost
- Describing the stationary phase as a solid: in GLC it is a liquid on a solid support.
- Comparing peak heights when the peaks have different widths.
- Explaining retention time with boiling point only, without the interaction with the stationary phase.
- Comparing retention times measured under different conditions.
- Forgetting that a single peak could hide two components with the same retention time.
- Saying the carrier gas dissolves or reacts with the sample.
Related resources
-
Study guides
Electrochemistry: Electrolysis and Standard Electrode Potentials
Quantitative electrolysis, the standard hydrogen electrode, cell potentials, feasibility and the Nernst equation, for Cambridge A Level Chemistry 9701.
Chemistry · Cambridge · A Level
Read guide -
Revision notes
Cambridge A Level Chemistry (9701): Gas/liquid chromatography – Revision Notes
Revision notes on GLC: the two phases, retention time, percentage composition from peak areas and explaining retention times, for Cambridge 9701 A Level.
Chemistry · Cambridge · A Level
Revise topic -
Study guides
Cambridge A Level Chemistry (9701): Proton (1H) NMR spectroscopy
Proton NMR for Cambridge 9701: predicting full spectra from the shift table, integration traces, n+1 splitting in esters, arenes and alcohols, and D₂O exchange.
Chemistry · Cambridge · A Level
Read guide
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.