Revision Notes
Cambridge A Level Chemistry (9701): Gas/liquid chromatography – Revision Notes
Revision notes on GLC: the two phases, retention time, percentage composition from peak areas and explaining retention times, for Cambridge 9701 A Level.
- Subject
- Chemistry
- Level
- A LEVEL
- Topic
- Analytical techniques
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Farhat ul Ain Sehgal (what this means)
Aligned to Cambridge A Level Chemistry (9701), 2025-2027. Official specification .
Syllabus page (what it covers and how it is assessed): Cambridge A Level Chemistry.
Syllabus points this page covers
9701 (A Level)
- 37.2 Gas / liquid chromatography
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Chemistry (9701).
Condensed for revision. For the full explanation, use the Gas/liquid chromatography study guide, then test yourself with the practice questions.
Syllabus: Cambridge International AS & A Level Chemistry 9701, 2025–2027, A Level subtopic 37.2: the terms stationary phase, mobile phase and retention time; interpreting chromatograms “in terms of the percentage composition of a mixture”; and explaining retention times “in terms of interaction with the stationary phase”.
The terms
| Term | Meaning in GLC |
|---|---|
| stationary phase | high boiling point, non-polar liquid coated on a solid support inside the column |
| mobile phase | unreactive (carrier) gas, e.g. nitrogen or helium |
| retention time | time from injection to the maximum of a component’s peak at the detector |
| chromatogram | trace of detector response against time; one peak per separated component |
- Stationary liquid has a high boiling point so it stays in the column at oven temperatures.
- Carrier gas is unreactive so it does not change the sample or the stationary phase.
- The sample must be volatile: it is vaporised on injection.
Retention time depends on conditions
| Change | Effect on retention times |
|---|---|
| higher column temperature | shorter |
| faster carrier gas flow | shorter |
| longer column | longer |
| different stationary phase | changes, and the order may change |
So compare retention times with a pure known sample on the same instrument under the same conditions.
Percentage composition
% of X = area of peak X ÷ total area of all peaks × 100
- Area is proportional to amount.
- Triangular peaks: area = ½ × base × height.
- Use heights only if all the peaks have the same width.
- Assumes the detector responds equally to each component (the 9701 convention).
Worked mini-example. Areas 15, 45 and 40 units: total 100, so 15%, 45% and 40%. Triangular peaks with base 0.2 min and height 6.0, and base 0.4 min and height 4.5: areas 0.60 and 0.90, so 40.0% and 60.0% (heights alone would wrongly suggest 57% and 43%).
Explaining retention times
- Non-polar stationary phase → main attraction is instantaneous dipole–induced dipole.
- Stronger attraction to the stationary phase → dissolves more → longer retention time.
- More electrons / longer chain → stronger attractions → longer time.
- Branched isomers: less surface contact → weaker attractions → shorter time than the straight-chain isomer.
- Order on a non-polar column often matches increasing boiling point, but explain using the stationary phase.
| Compounds | Order out of the column (first → last) | Reason |
|---|---|---|
| pentane, hexane, heptane | pentane → hexane → heptane | more electrons, stronger attraction to stationary phase |
| 2,2-dimethylpropane, pentane | 2,2-dimethylpropane → pentane | branching reduces surface contact |
Interpreting a chromatogram
- Count the peaks: at least that many components.
- Match retention times with references run under the same conditions.
- Measure or calculate peak areas.
- Convert to percentages of the total area.
- State conclusions with “probably” unless confirmed under a second set of conditions.
Key terms
| Term | Meaning |
|---|---|
| carrier gas | the unreactive gas that is the mobile phase |
| column | long, narrow tube holding the stationary phase |
| detector | device at the column outlet that responds to each component |
| peak area | area under a peak, proportional to the amount of that component |
| volatile | easily vaporised |
| instantaneous dipole–induced dipole forces | attractions between non-polar molecules, stronger with more electrons |
Exam traps
- In GLC the stationary phase is a liquid (on a solid support), not a solid.
- The carrier gas is unreactive; never say it reacts with the sample.
- Use areas, not heights, unless the widths are equal.
- Retention time is read at the peak maximum.
- Do not compare retention times measured under different conditions.
- Explain with interaction with the stationary phase; boiling point alone is incomplete.
- A single peak does not prove a pure sample: two components could have the same retention time.
Self-test
- Describe the stationary phase in GLC.
- Name a suitable mobile phase and say why it must be unreactive.
- Define retention time.
- Why must the stationary liquid have a high boiling point?
- State two conditions that affect retention time.
- Peak areas are 24, 36 and 60. Calculate the percentage of the second component.
- A triangular peak has base 0.30 min and height 7.0. Calculate its area.
- When can peak heights be used instead of areas?
- Which leaves the column first, octane or hexane? Explain.
- Why does 2-methylbutane have a shorter retention time than pentane?
- How would raising the column temperature affect all retention times?
- A sample gives one peak at the same retention time as pure ethanol. Is the sample definitely pure ethanol?
Answers:
- A non-polar liquid with a high boiling point, coated on a solid support in the column.
- Nitrogen or helium; so that it does not react with the sample or stationary phase.
- Time from injection to the maximum of the component’s peak at the detector.
- So it stays liquid in the heated column and is not carried away by the gas.
- Any two: column temperature; carrier gas flow rate; column length; type of stationary phase.
- 36 / 120 × 100 = 30%.
- ½ × 0.30 × 7.0 = 1.05.
- When all the peaks have the same width.
- Hexane: it has fewer electrons, so weaker instantaneous dipole–induced dipole attractions to the stationary phase, and spends less time dissolved in it.
- It is branched, so it has less surface contact and weaker attractions to the stationary phase.
- They would all decrease, because components spend more time as vapour.
- No: another compound could have the same retention time; it is probably ethanol.
These are original notes written for revision. Check the full syllabus wording in the official 9701 syllabus.
Related resources
-
Study guides
Electrochemistry: Electrolysis and Standard Electrode Potentials
Quantitative electrolysis, the standard hydrogen electrode, cell potentials, feasibility and the Nernst equation, for Cambridge A Level Chemistry 9701.
Chemistry · Cambridge · A Level
Read guide -
Study guides
Cambridge A Level Chemistry (9701): Proton (1H) NMR spectroscopy
Proton NMR for Cambridge 9701: predicting full spectra from the shift table, integration traces, n+1 splitting in esters, arenes and alcohols, and D₂O exchange.
Chemistry · Cambridge · A Level
Read guide -
Practice questions
Cambridge A Level Chemistry (9701): Proton (1H) NMR spectroscopy – Practice Questions
Original proton NMR practice for Cambridge 9701: predicting shifts and splitting, integration traces, ester and arene deductions and D₂O tests, with answers.
Chemistry · Cambridge · A Level
Try questions
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.