Study Guides
Cambridge A Level Chemistry (9701): Gas/liquid chromatography
Gas/liquid chromatography phases, retention time, percentage composition from peak areas and explaining retention times, for Cambridge 9701.
- Subject
- Chemistry
- Level
- A LEVEL
- Topic
- Analytical techniques
- Author
- Marlbridge Academic Team
- Updated
- Reviewed by
- Farhat ul Ain Sehgal (what this means)
Aligned to Cambridge A Level Chemistry (9701), 2025-2027. Official specification .
Syllabus page (what it covers and how it is assessed): Cambridge A Level Chemistry.
Syllabus points this page covers
9701 (A Level)
- 37.2 Gas / liquid chromatography
Found an error? Report a correction.
Need help with this topic? Request a free trial class for A Level Chemistry (9701).
This guide covers subtopic 37.2, Gas/liquid chromatography, from Topic 37, Analytical techniques, of Cambridge International AS & A Level Chemistry 9701, 2025–2027 series. It is A Level content. The broader Chromatography: Thin-Layer and Gas/Liquid study guide gives the definitions and one percentage calculation; this page adds peak areas from peak dimensions, the conditions that change retention times, and a method for explaining the order in which components leave the column.
What the syllabus asks for
Subtopic 37.2 has three learning outcomes:
- describe and understand the terms: “stationary phase; a high boiling point non-polar liquid (on a solid support)”; “mobile phase; an unreactive gas”; “retention time”
- “interpret gas / liquid chromatograms in terms of the percentage composition of a mixture”
- “explain retention times in terms of interaction with the stationary phase”
How the technique works
- A small sample of the mixture is injected into a heated port, where it vaporises.
- An unreactive carrier gas (the mobile phase), such as nitrogen or helium, sweeps the vapour into a long, thin column inside an oven.
- The column holds the stationary phase: a non-polar liquid with a high boiling point, coated on an inert solid support. Its high boiling point means it stays liquid in the oven and is not carried away by the gas.
- Each component is shared between the moving gas and the stationary liquid. Components that spend more time dissolved in the liquid move through the column more slowly.
- A detector at the far end records each component as it leaves, producing a chromatogram: detector response plotted against time.
The carrier gas must be unreactive so that it does not react with the sample or the stationary phase, and so that the components reach the detector unchanged.
Retention time
Retention time is the time between injecting the sample and the component reaching the detector, read at the maximum of its peak.
Retention time is characteristic of a compound only under fixed conditions. It changes with:
- the column temperature (higher temperature → components spend more time as vapour → shorter retention times);
- the flow rate of the carrier gas (faster flow → shorter retention times);
- the length of the column and the nature of the stationary phase.
So to identify a component, compare its retention time with that of a known pure compound run on the same instrument under the same conditions.
Percentage composition from peak areas
The area under each peak is proportional to the amount of that component. So:
percentage of component X = (area of peak X ÷ total area of all peaks) × 100
Finding areas. Exam chromatograms often show peaks as triangles or near-triangles. Then:
area of a triangular peak = ½ × base width × height
If all peaks have the same width, the heights alone can be compared, but check the widths before using that short cut.
An assumption. The calculation treats the detector as responding equally to every component. In 9701 questions you take the peak-area percentage as the percentage composition of the mixture.
Explaining retention times
The syllabus asks you to explain retention times “in terms of interaction with the stationary phase”. The stationary phase is a non-polar liquid, so the main attractions between it and a component are instantaneous dipole–induced dipole forces.
- Stronger interaction with the stationary phase (the component dissolves well in it) → the component spends more time in the liquid → longer retention time.
- Weaker interaction → more time in the gas → shorter retention time.
Instantaneous dipole–induced dipole forces are stronger for molecules with more electrons and larger surface area. That gives three reliable patterns:
- Homologous series: retention time increases with chain length (pentane < hexane < heptane).
- Branching: a branched isomer has a smaller surface area for contact, interacts less, and usually comes out before its straight-chain isomer.
- Volatility link: compounds with stronger intermolecular forces usually have higher boiling points as well, so on a non-polar column components often leave in order of increasing boiling point. Use this as supporting evidence, but always state the interaction with the stationary phase.
Worked example 1: percentage composition from triangular peaks
Question. A chromatogram of a three-component mixture shows triangular peaks.
| Peak | Base width / min | Height / arbitrary units |
|---|---|---|
| 1 | 0.40 | 5.0 |
| 2 | 0.60 | 8.0 |
| 3 | 0.50 | 3.2 |
Calculate the percentage of each component.
Answer.
- Areas: peak 1 = ½ × 0.40 × 5.0 = 1.0; peak 2 = ½ × 0.60 × 8.0 = 2.4; peak 3 = ½ × 0.50 × 3.2 = 0.80
- Total area = 1.0 + 2.4 + 0.80 = 4.2
- Peak 1: 1.0 / 4.2 × 100 = 23.8%; peak 2: 2.4 / 4.2 × 100 = 57.1%; peak 3: 0.80 / 4.2 × 100 = 19.0%
Examiner’s note: comparing heights alone would give 5.0 : 8.0 : 3.2 and the wrong answer, because the peaks have different widths. The percentages sum to 99.9% only because of rounding.
Worked example 2: explaining an order of retention times
Question. A mixture of hexane, heptane and 2-methylpentane is analysed on a non-polar column. Predict the order in which they reach the detector and explain it.
Answer. Order: 2-methylpentane, then hexane, then heptane.
- Heptane has the most electrons, so it has the strongest instantaneous dipole–induced dipole attractions to the non-polar stationary phase. It dissolves best, spends most time in the liquid and has the longest retention time.
- Hexane and 2-methylpentane have the same number of electrons, but 2-methylpentane is branched, so it has less surface contact with the stationary phase. Its attractions are weaker and it leaves first.
Worked example 3: interpreting a chromatogram with a reference
Question. A sample gives peaks at 2.1, 3.4 and 5.8 minutes. A pure sample of ethyl ethanoate, run on the same instrument under the same conditions, gives a peak at 3.4 minutes. What can be concluded?
Answer. The sample probably contains ethyl ethanoate, which gave the peak at 3.4 minutes. There are at least three components. To be more confident, the retention time could be compared again under a second set of conditions (for example a different column temperature), in which a match should still be found.
Common mistakes
- Calling the stationary phase a solid. In GLC it is a liquid on a solid support.
- Saying the carrier gas “reacts with” or “dissolves” the sample. It is unreactive and simply carries the vapour.
- Comparing heights instead of areas when peaks have different widths.
- Measuring retention time to the start of a peak instead of its maximum.
- Explaining retention time only by boiling point without mentioning the stationary phase.
- Comparing retention times from different instruments or conditions.
Exam technique for the command words
- Describe the terms: give the syllabus phrase and an example (nitrogen or helium; a non-polar liquid of high boiling point on a solid support).
- Interpret a chromatogram: identify peaks by retention time, then calculate areas and percentages, showing each area.
- Calculate: write each area, the total, and each percentage, to three significant figures where the data allow.
- Explain retention times: name the intermolecular force with the stationary phase, say which component interacts more strongly, and link that to a longer time.
Condense this page with the Gas/liquid chromatography revision notes, then test yourself with the Gas/liquid chromatography practice questions. For the other chromatography technique in Topic 37, see the Thin-layer chromatography study guide.
Written against Cambridge International AS & A Level Chemistry 9701, 2025–2027 series. Always check the current syllabus for your examination year.
Related resources
-
Study guides
Electrochemistry: Electrolysis and Standard Electrode Potentials
Quantitative electrolysis, the standard hydrogen electrode, cell potentials, feasibility and the Nernst equation, for Cambridge A Level Chemistry 9701.
Chemistry · Cambridge · A Level
Read guide -
Practice questions
Cambridge A Level Chemistry (9701): Gas/liquid chromatography – Practice Questions
Original practice questions with full answers on GLC phases, retention times, peak-area percentages and explaining elution order, for Cambridge 9701 Chemistry.
Chemistry · Cambridge · A Level
Try questions -
Revision notes
Cambridge A Level Chemistry (9701): Gas/liquid chromatography – Revision Notes
Revision notes on GLC: the two phases, retention time, percentage composition from peak areas and explaining retention times, for Cambridge 9701 A Level.
Chemistry · Cambridge · A Level
Revise topic
Related articles
Get free revision emails (optional)
Occasional emails with practice questions, worked explanations and links to free resources for the qualification and subjects you choose. No spam, and you can unsubscribe from any email. The free tools on this site never need an email.